5,810 research outputs found

    SCMA with Low Complexity Symmetric Codebook Design for Visible Light Communication

    Full text link
    Sparse code multiple access (SCMA) is attracting significant research interests currently, which is considered as a promising multiple access technique for 5G systems. It serves as a good candidate for the future communication network with massive nodes due to its capability of handling user overloading. Introducing SCMA to visible light communication (VLC) can provide another opportunity on design of transmission protocols for the communication network with massive nodes due to the limited communication range of VLC, which reduces the interference intensity. However, when applying SCMA in VLC systems, we need to modify the SCMA codebook to accommodate the real and positive signal requirement for VLC.We apply multidimensional constellation design methods to SCMA codebook. To reduce the design complexity, we also propose a symmetric codebook design. For all the proposed design approaches, the minimum Euclidean distance aims to be maximized. Our symmetric codebook design can reduce design and detection complexity simultaneously. Simulation results show that our design implies fast convergence with respect to the number of iterations, and outperforms the design that simply modifies the existing approaches to VLC signal requirements

    Compressive Sensing Theory for Optical Systems Described by a Continuous Model

    Full text link
    A brief survey of the author and collaborators' work in compressive sensing applications to continuous imaging models.Comment: Chapter 3 of "Optical Compressive Imaging" edited by Adrian Stern published by Taylor & Francis 201

    Learning Adaptive Discriminative Correlation Filters via Temporal Consistency Preserving Spatial Feature Selection for Robust Visual Tracking

    Get PDF
    With efficient appearance learning models, Discriminative Correlation Filter (DCF) has been proven to be very successful in recent video object tracking benchmarks and competitions. However, the existing DCF paradigm suffers from two major issues, i.e., spatial boundary effect and temporal filter degradation. To mitigate these challenges, we propose a new DCF-based tracking method. The key innovations of the proposed method include adaptive spatial feature selection and temporal consistent constraints, with which the new tracker enables joint spatial-temporal filter learning in a lower dimensional discriminative manifold. More specifically, we apply structured spatial sparsity constraints to multi-channel filers. Consequently, the process of learning spatial filters can be approximated by the lasso regularisation. To encourage temporal consistency, the filter model is restricted to lie around its historical value and updated locally to preserve the global structure in the manifold. Last, a unified optimisation framework is proposed to jointly select temporal consistency preserving spatial features and learn discriminative filters with the augmented Lagrangian method. Qualitative and quantitative evaluations have been conducted on a number of well-known benchmarking datasets such as OTB2013, OTB50, OTB100, Temple-Colour, UAV123 and VOT2018. The experimental results demonstrate the superiority of the proposed method over the state-of-the-art approaches

    Exploiting flow dynamics for super-resolution in contrast-enhanced ultrasound

    Get PDF
    Ultrasound localization microscopy offers new radiation-free diagnostic tools for vascular imaging deep within the tissue. Sequential localization of echoes returned from inert microbubbles with low-concentration within the bloodstream reveal the vasculature with capillary resolution. Despite its high spatial resolution, low microbubble concentrations dictate the acquisition of tens of thousands of images, over the course of several seconds to tens of seconds, to produce a single super-resolved image. %since each echo is required to be well separated from adjacent microbubbles. Such long acquisition times and stringent constraints on microbubble concentration are undesirable in many clinical scenarios. To address these restrictions, sparsity-based approaches have recently been developed. These methods reduce the total acquisition time dramatically, while maintaining good spatial resolution in settings with considerable microbubble overlap. %Yet, non of the reported methods exploit the fact that microbubbles actually flow within the bloodstream. % to improve recovery. Here, we further improve sparsity-based super-resolution ultrasound imaging by exploiting the inherent flow of microbubbles and utilize their motion kinematics. While doing so, we also provide quantitative measurements of microbubble velocities. Our method relies on simultaneous tracking and super-localization of individual microbubbles in a frame-by-frame manner, and as such, may be suitable for real-time implementation. We demonstrate the effectiveness of the proposed approach on both simulations and {\it in-vivo} contrast enhanced human prostate scans, acquired with a clinically approved scanner.Comment: 11 pages, 9 figure
    • …
    corecore