16,227 research outputs found

    Influence of grid configuration on current conducting behaviour in PV installations

    Get PDF
    On the roof of an industrial site a 385 kWp PhotoVoltaic installation is operational. When production of this system reaches 60% of the installed power, the circuit breaker trips. At sufficient production, measurements show a high distortion of phase voltage and variable waveform of both phase voltage and current. Analysis of the installation showed that a Yy0 transformer is used introducing a high zero sequence impedance. Unbalance in the injected current combined with a high zero sequence impedance leads to a high neutral-ground voltage and distorted phase-neutral voltages. In this paper it will be shown that the tripping of the circuit breaker is caused by the measurement method of the device. This paper analyses the practical measurement results, causes of errors and the solution to the stated problem

    Partial Discharge in Electronic Equipments

    Get PDF
    Tato disertačnĂ­ prĂĄce se věnuje studiu částečnĂœch vĂœbojĆŻ (PD) zpĆŻsobenĂœch poklesem spolehlivosti a ĆŸivotnosti elektronickĂœch zaƙízenĂ­ a systĂ©mĆŻ. Diagnostika PD je dnes znĂĄmĂĄ metoda pro vysokĂ© napětĂ­ u vysoko-vĂœkonnĂœch zaƙízenĂ­. V pƙípadě elektronickĂœch zaƙízenĂ­ PD testovĂĄnĂ­ nenĂ­ ale bÄ›ĆŸně pouĆŸĂ­vĂĄnĂĄ metoda, pƙestoĆŸe je zde takĂ© potenciĂĄl pro vysokĂ© elektrickĂ© zatĂ­ĆŸenĂ­ vzhledem k velmi krĂĄtkĂ© vzdĂĄlenosti. Tato prĂĄce je zaměƙena na vyĆĄetƙovĂĄnĂ­ PD činnosti u elektronickĂœch zaƙízenĂ­. Bylo navrĆŸeno a provedeno pracoviĆĄtě pro diagnostiku PD v elektronickĂœch zaƙízenĂ­ch. PracovnĂ­ frekvence se pohybuje od několika stovek Hz aĆŸ 100 kHz. MaximĂĄlnĂ­ amplituda PD testovanĂ©ho napětĂ­ je vyĆĄĆĄĂ­ neĆŸ 10 kV. Navzdory jednoduchĂ© konstrukci toto zaƙízenĂ­ pƙinĂĄĆĄĂ­ vysokou spolehlivost měƙenĂ­. VĂ­ce neĆŸ 300 PD testĆŻ bylo provedeno na rĆŻznĂœch elektronickĂœch zaƙízenĂ­ch a elektronickĂœch součástĂ­,napƙ. na planĂĄrnĂ­ch transformĂĄtorech a elektronickĂœch komponentĂĄch pouĆŸĂ­vanĂœch pƙi vysoko-napěƄovĂœch měničíchThis dissertation thesis is devoted to study of partial discharge (PD) caused decrease of reliability and lifetime of electronic equipments and systems. PD diagnostic is nowadays well known method for high voltage high power equipments but in case of electronic devices PD testing it is not used routinely despite that there is also a potential for high electric load due to extremely short distances. The risk of PD caused failure is here extremely high because of high working frequency and consequently high repetition rate of PD events. Therefore, this work is focused on investigation of PD activity in electronic equipments. The workplace for PD diagnostic in electronic devices based on switched power supply was designed and made. Working frequency ranges from several hundreds of Hertz up to 100 kHz. The maximal amplitude of PD testing voltage is higher than 10 kV. Despite the simple design this equipment brings high repeatability and reliability of measurement. More than 300 PD tests were made on different electronic devices and electronic components, on planar transformers, and on components for voltage gate drivers for use in high voltage power converters. Possibilities of PD tools in investigation and engineering ofd insulation systems were demonstrated.

    Linearized large signal modeling, analysis, and control design of phase-controlled series-parallel resonant converters using state feedback

    Get PDF
    This paper proposes a linearized large signal state-space model for the fixed-frequency phase-controlled series-parallel resonant converter. The proposed model utilizes state feedback of the output filter inductor current to perform linearization. The model combines multiple-frequency and average state-space modeling techniques to generate an aggregate model with dc state variables that are relatively easier to control and slower than the fast resonant tank dynamics. The main objective of the linearized model is to provide a linear representation of the converter behavior under large signal variation which is suitable for faster simulation and large signal estimation/calculation of the converter state variables. The model also provides insight into converter dynamics as well as a simplified reduced order transfer function for PI closed-loop design. Experimental and simulation results from a detailed switched converter model are compared with the proposed state-space model output to verify its accuracy and robustness

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Analysis and control of dual-output LCLC resonant converters with significant leakage inductance

    Get PDF
    The analysis, design and control of fourth-order LCLC voltage-output series-parallel resonant converters for the provision of multiple regulated outputs, is described. Specifically, state-variable concepts are developed to establish operating mode boundaries with which to describe the internal behavior and the impact of output leakage inductance. The resulting models are compared with those obtained from SPICE simulations and measurements from a prototype power supply under closed loop control to verify the analysis, modeling, and control predictions

    Modelling and regulation of dual-output LCLC resonant converters

    Get PDF
    The analysis, design and control of 4th-order LCLC voltage-output series-parallel resonant converters (SPRCs) for the provision of multiple regulated outputs, is described. Specifically, state-variable concepts are employed and new analysis techniques are developed to establish operating mode boundaries with which to describe the internal behaviour of a dual-output resonant converter topology. The designer is guided through the most important criteria for realising a satisfactory converter, and the impact of parameter choices on performance is explored. Predictions from the resulting models are compared with those obtained from SPICE simulations and measurements from a prototype power supply under closed loop control

    European White Book on Real-Time Power Hardware in the Loop Testing : DERlab Report No. R- 005.0

    Get PDF
    The European White Book on Real-Time-Powerhardware-in-the-Loop testing is intended to serve as a reference document on the future of testing of electrical power equipment, with speciïŹ c focus on the emerging hardware-in-the-loop activities and application thereof within testing facilities and procedures. It will provide an outlook of how this powerful tool can be utilised to support the development, testing and validation of speciïŹ cally DER equipment. It aims to report on international experience gained thus far and provides case studies on developments and speciïŹ c technical issues, such as the hardware/software interface. This white book compliments the already existing series of DERlab European white books, covering topics such as grid-inverters and grid-connected storag

    Smart microgrids and virtual power plants in a hierarchical control structure

    Get PDF
    In order to achieve a coordinated integration of distributed energy resources in the electrical network, an aggregation of these resources is required. Microgrids and virtual power plants (VPPs) address this issue. Opposed to VPPs, microgrids have the functionality of islanding, for which specific control strategies have been developed. These control strategies are classified under the primary control strategies. Microgrid secondary control deals with other aspects such as resource allocation, economic optimization and voltage profile improvements. When focussing on the control-aspects of DER, VPP coordination is similar with the microgrid secondary control strategy, and thus, operates at a slower time frame as compared to the primary control and can take full advantage of the available communication provided by the overlaying smart grid. Therefore, the feasibility of the microgrid secondary control for application in VPPs is discussed in this paper. A hierarchical control structure is presented in which, firstly, smart microgrids deal with local issues in a primary and secondary control. Secondly, these microgrids are aggregated in a VPP that enables the tertiary control, forming the link with the electricity markets and dealing with issues on a larger scale

    Smart grids for rural conditions and e-mobility - Applying power routers, batteries and virtual power plants

    Get PDF
    Significant reductions of greenhouse gas emission by use of renewable energy sources belong to the common targets of the European Union. Smart grids address intelligent use and integration of conventional and renewable generation in combination with controllable loads and storages. Two special aspects have also to be considered for smart grids in future: rural conditions and electric vehicles. Both, the increasing share of renewable energy sources and a rising demand for charging power by electrical vehicles lead to new challenges of network stability (congestion, voltage deviation), especially in rural distribution grids. This paper describes two lighthouse projects in Europe (“Well2Wheel” and “Smart Rural Grid”) dealing with these topics. The link between these projects is the implementation of the same virtual power plant technology and the approach of cellular grid cells. Starting with an approach for the average energy balance in 15 minutes intervals in several grid cells in the first project, the second project even allows the islanded operation of such cells as a microgrid. The integration of renewable energy sources into distribution grids primary takes place in rural areas. The lighthouse project “Smart Rural Grid”, which is founded by the European Union, demonstrates possibilities to use the existing distribution system operator infrastructure more effectively by applying an optimised and scheduled operation of the assets and using intelligent distribution power routers, called IDPR. IDPR are active power electronic devices operating at low voltage in distribution grids aiming to reduce losses due to unbalanced loads and enabling active voltage and reactive power control. This allows a higher penetration of renewable energy sources in existing grids without investing in new lines and transformers. Integrated in a virtual power plant and combined with batteries, the IDPR also allows a temporary islanded mode of grid cells. Both projects show the potential of avoiding or postponing investments in new primary infrastructure like cables, transformers and lines by using a forward-looking operation which controls generators, loads and batteries (mobile and stationary) by using new grid assets like power routers. While primary driven by physical restrictions as voltage-band violations and energy balance, these cells also define and allow local smart markets. In consequence the distribution system operators could avoid direct control access by giving an incentive to the asset owners by local price signals according to the grid situation and forecasted congestions.Peer ReviewedPostprint (published version
    • 

    corecore