38 research outputs found

    Reconstruction of coronary arteries from X-ray angiography: A review.

    Get PDF
    Despite continuous progress in X-ray angiography systems, X-ray coronary angiography is fundamentally limited by its 2D representation of moving coronary arterial trees, which can negatively impact assessment of coronary artery disease and guidance of percutaneous coronary intervention. To provide clinicians with 3D/3D+time information of coronary arteries, methods computing reconstructions of coronary arteries from X-ray angiography are required. Because of several aspects (e.g. cardiac and respiratory motion, type of X-ray system), reconstruction from X-ray coronary angiography has led to vast amount of research and it still remains as a challenging and dynamic research area. In this paper, we review the state-of-the-art approaches on reconstruction of high-contrast coronary arteries from X-ray angiography. We mainly focus on the theoretical features in model-based (modelling) and tomographic reconstruction of coronary arteries, and discuss the evaluation strategies. We also discuss the potential role of reconstructions in clinical decision making and interventional guidance, and highlight areas for future research

    Object-Based 3-D Reconstruction of Arterial Trees from Magnetic Resonance Angiograms

    Full text link
    By exploiting a priori knowledge of arterial shape and smoothness, subpixel accuracy reconstructions are achieved from only four noisy projection images. The method incorporates a priori knowledge of the structure of branching arteries into a natural optimality criterion that encompasses the entire arterial tree. An efficient optimization algorithm for object estimation is presented, and its performance on simulated, phantom, and in vivo magnetic resonance angiograms is demonstrated. It is shown that accurate reconstruction of bifurcations is achievable with parametric models.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85841/1/Fessler111.pd

    3D reconstruction of coronary arteries from angiographic sequences for interventional assistance

    Get PDF
    Introduction -- Review of literature -- Research hypothesis and objectives -- Methodology -- Results and discussion -- Conclusion and future perspectives

    Specular reflection removal and bloodless vessel segmentation for 3-D heart model reconstruction from single view images

    Get PDF
    Three Dimensional (3D) human heart model is attracting attention for its role in medical images for education and clinical purposes. Analysing 2D images to obtain meaningful information requires a certain level of expertise. Moreover, it is time consuming and requires special devices to obtain aforementioned images. In contrary, a 3D model conveys much more information. 3D human heart model reconstruction from medical imaging devices requires several input images, while reconstruction from a single view image is challenging due to the colour property of the heart image, light reflections, and its featureless surface. Lights and illumination condition of the operating room cause specular reflections on the wet heart surface that result in noises forming of the reconstruction process. Image-based technique is used for the proposed human heart surface reconstruction. It is important the reflection is eliminated to allow for proper 3D reconstruction and avoid imperfect final output. Specular reflections detection and correction process examine the surface properties. This was implemented as a first step to detect reflections using the standard deviation of RGB colour channel and the maximum value of blue channel to establish colour, devoid of specularities. The result shows the accurate and efficient performance of the specularities removing process with 88.7% similarity with the ground truth. Realistic 3D heart model reconstruction was developed based on extraction of pixel information from digital images to allow novice surgeons to reduce the time for cardiac surgery training and enhancing their perception of the Operating Theatre (OT). Cardiac medical imaging devices such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT) images, or Echocardiography provide cardiac information. However,these images from medical modalities are not adequate, to precisely simulate the real environment and to be used in the training simulator for cardiac surgery. The propose method exploits and develops techniques based on analysing real coloured images taken during cardiac surgery in order to obtain meaningful information of the heart anatomical structures. Another issue is the different human heart surface vessels. The most important vessel region is the bloodless, lack of blood, vessels. Surgeon faces some difficulties in locating the bloodless vessel region during surgery. The thesis suggests a technique of identifying the vessels’ Region of Interest (ROI) to avoid surgical injuries by examining an enhanced input image. The proposed method locates vessels’ ROI by using Decorrelation Stretch technique. This Decorrelation Stretch can clearly enhance the heart’s surface image. Through this enhancement, the surgeon become enables effectively identifying the vessels ROI to perform the surgery from textured and coloured surface images. In addition, after enhancement and segmentation of the vessels ROI, a 3D reconstruction of this ROI takes place and then visualize it over the 3D heart model. Experiments for each phase in the research framework were qualitatively and quantitatively evaluated. Two hundred and thirteen real human heart images are the dataset collected during cardiac surgery using a digital camera. The experimental results of the proposed methods were compared with manual hand-labelling ground truth data. The cost reduction of false positive and false negative of specular detection and correction processes of the proposed method was less than 24% compared to other methods. In addition, the efficient results of Root Mean Square Error (RMSE) to measure the correctness of the z-axis values to reconstruction of the 3D model accurately compared to other method. Finally, the 94.42% accuracy rate of the proposed vessels segmentation method using RGB colour space achieved is comparable to other colour spaces. Experimental results show that there is significant efficiency and robustness compared to existing state of the art methods

    Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates

    Get PDF
    The study of cerebral anatomy in developing neonates is of great importance for the understanding of brain development during the early period of life. This dissertation therefore focuses on three challenges in the modelling of cerebral anatomy in neonates during brain development. The methods that have been developed all use Magnetic Resonance Images (MRI) as source data. To facilitate study of vascular development in the neonatal period, a set of image analysis algorithms are developed to automatically extract and model cerebral vessel trees. The whole process consists of cerebral vessel tracking from automatically placed seed points, vessel tree generation, and vasculature registration and matching. These algorithms have been tested on clinical Time-of- Flight (TOF) MR angiographic datasets. To facilitate study of the neonatal cortex a complete cerebral cortex segmentation and reconstruction pipeline has been developed. Segmentation of the neonatal cortex is not effectively done by existing algorithms designed for the adult brain because the contrast between grey and white matter is reversed. This causes pixels containing tissue mixtures to be incorrectly labelled by conventional methods. The neonatal cortical segmentation method that has been developed is based on a novel expectation-maximization (EM) method with explicit correction for mislabelled partial volume voxels. Based on the resulting cortical segmentation, an implicit surface evolution technique is adopted for the reconstruction of the cortex in neonates. The performance of the method is investigated by performing a detailed landmark study. To facilitate study of cortical development, a cortical surface registration algorithm for aligning the cortical surface is developed. The method first inflates extracted cortical surfaces and then performs a non-rigid surface registration using free-form deformations (FFDs) to remove residual alignment. Validation experiments using data labelled by an expert observer demonstrate that the method can capture local changes and follow the growth of specific sulcus

    Reconstruction of Coronary Arteries from X-ray Rotational Angiography

    Get PDF

    Combinatorial optimisation for arterial image segmentation.

    Get PDF
    Cardiovascular disease is one of the leading causes of the mortality in the western world. Many imaging modalities have been used to diagnose cardiovascular diseases. However, each has different forms of noise and artifacts that make the medical image analysis field important and challenging. This thesis is concerned with developing fully automatic segmentation methods for cross-sectional coronary arterial imaging in particular, intra-vascular ultrasound and optical coherence tomography, by incorporating prior and tracking information without any user intervention, to effectively overcome various image artifacts and occlusions. Combinatorial optimisation methods are proposed to solve the segmentation problem in polynomial time. A node-weighted directed graph is constructed so that the vessel border delineation is considered as computing a minimum closed set. A set of complementary edge and texture features is extracted. Single and double interface segmentation methods are introduced. Novel optimisation of the boundary energy function is proposed based on a supervised classification method. Shape prior model is incorporated into the segmentation framework based on global and local information through the energy function design and graph construction. A combination of cross-sectional segmentation and longitudinal tracking is proposed using the Kalman filter and the hidden Markov model. The border is parameterised using the radial basis functions. The Kalman filter is used to adapt the inter-frame constraints between every two consecutive frames to obtain coherent temporal segmentation. An HMM-based border tracking method is also proposed in which the emission probability is derived from both the classification-based cost function and the shape prior model. The optimal sequence of the hidden states is computed using the Viterbi algorithm. Both qualitative and quantitative results on thousands of images show superior performance of the proposed methods compared to a number of state-of-the-art segmentation methods

    DYNAMIC MEASUREMENT OF THREE-DIMENSIONAL MOTION FROM SINGLE-PERSPECTIVE TWO-DIMENSIONAL RADIOGRAPHIC PROJECTIONS

    Get PDF
    The digital evolution of the x-ray imaging modality has spurred the development of numerous clinical and research tools. This work focuses on the design, development, and validation of dynamic radiographic imaging and registration techniques to address two distinct medical applications: tracking during image-guided interventions, and the measurement of musculoskeletal joint kinematics. Fluoroscopy is widely employed to provide intra-procedural image-guidance. However, its planar images provide limited information about the location of surgical tools and targets in three-dimensional space. To address this limitation, registration techniques, which extract three-dimensional tracking and image-guidance information from planar images, were developed and validated in vitro. The ability to accurately measure joint kinematics in vivo is an important tool in studying both normal joint function and pathologies associated with injury and disease, however it still remains a clinical challenge. A technique to measure joint kinematics from single-perspective x-ray projections was developed and validated in vitro, using clinically available radiography equipmen

    Application of Patient-Specific Computational Fluid Dynamics in Coronary and Intra-Cardiac Flow Simulations: Challenges and Opportunities

    Get PDF
    The emergence of new cardiac diagnostics and therapeutics of the heart has given rise to the challenging field of virtual design and testing of technologies in a patient-specific environment. Given the recent advances in medical imaging, computational power and mathematical algorithms, patient-specific cardiac models can be produced from cardiac images faster, and more efficiently than ever before. The emergence of patient-specific computational fluid dynamics (CFD) has paved the way for the new field of computer-aided diagnostics. This article provides a review of CFD methods, challenges and opportunities in coronary and intra-cardiac flow simulations. It includes a review of market products and clinical trials. Key components of patient-specific CFD are covered briefly which include image segmentation, geometry reconstruction, mesh generation, fluid-structure interaction, and solver techniques
    corecore