142 research outputs found
Edge enhanced spatio-temporal constrained reconstruction of undersampled dynamic contrast enhanced radial MRI
Journal ArticleThere are many applications in MRI where it is desirable to have high spatial and high temporal resolution. This can be achieved by undersampling of k-space and requires special techniques for reconstruction. Even if undersampling artifacts are removed, sharpness of the edges can be a problem. We propose a new technique that uses the gradient from a reference image to improve the quality of the edges in the reconstructed image along with a spatio-temporal constraint to reduce aliasing artifacts and noise. The reference is created from undersampled dynamic data by combining several adjacent frames. The method was tested on undersampled radial DCE MRI data with little respiratory motion. The proposed method was compared to reconstruction using the spatio-temporal constrained reconstruction. Sharper edges and an increase in the contrast was observed by using the proposed method
Real-Time Magnetic Resonance Imaging
Real‐time magnetic resonance imaging (RT‐MRI) allows for imaging dynamic processes as they occur, without relying on any repetition or synchronization. This is made possible by modern MRI technology such as fast‐switching gradients and parallel imaging. It is compatible with many (but not all) MRI sequences, including spoiled gradient echo, balanced steady‐state free precession, and single‐shot rapid acquisition with relaxation enhancement. RT‐MRI has earned an important role in both diagnostic imaging and image guidance of invasive procedures. Its unique diagnostic value is prominent in areas of the body that undergo substantial and often irregular motion, such as the heart, gastrointestinal system, upper airway vocal tract, and joints. Its value in interventional procedure guidance is prominent for procedures that require multiple forms of soft‐tissue contrast, as well as flow information. In this review, we discuss the history of RT‐MRI, fundamental tradeoffs, enabling technology, established applications, and current trends
Recommended from our members
Advanced H-1 Lung Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is one of the widely used medical imaging modality, since it can provide both structural and functional assessment in a single imaging session. However, two major challenges should be considered by using MRI for lung imaging. The first challenge is the intrinsic low SNR of H-1 lung MRI due to the low proton density as well as the fast decay of the lung parenchyma signal. And the second challenge is subject motion. To achieve high resolution structural image, MRI requires a long scan time, usually a few minutes or even longer, which make MRI sensitive to subject motion. To address the first challenge, ultra-short echo time (UTE) MRI sequence is used to capture the lung parenchyma signal before decay. As for subject motion, two major strategies are widely used. One strategy is fast breath-holding scan, the subjects are asked to hold their breaths for a short duration, and the fast 3D MR sequence would be used to acquire data within that duration. This dissertation proposes a new acquisition scheme based on the standard UTE sequence, which largely increases the encoding efficiency and improves the breath-holding scan images. The other is free breathing scan with motion correction. The subjects are allowed to breathe during the MR acquisition. After the acquisition, the motion corrupted data would go through the motion correction step to reconstruct the motion free images. In this dissertation, two novel motion corrected reconstruction strategies are proposed to incorporate the motion modeling and compensation into the reconstruction to get high SNR motion corrected 3D and 4D images. When translating the developed techniques to the clinical studies, specifically for pediatric and neonatal studies, more practical problems need to be considered, such as smaller but finer anatomy to image, the different respiratory patterns of the young subjects etc. This dissertation proposes a 5-minute free breathing UTE MRI strategy to achieve a 3D high resolution motion free lung image for pediatric and neonatal studies
- …