58 research outputs found

    Electrocardiogram Baseline Wander Suppression Based on the Combination of Morphological and Wavelet Transformation Based Filtering

    Get PDF
    One of the major noise components in electrocardiogram (ECG) is the baseline wander (BW). Effective methods for suppressing BW include the wavelet-based (WT) and the mathematical morphological filtering-based (MMF)algorithms. However, the T waveform distortions introduced by the WTand the rectangular/trapezoidal distortions introduced by MMF degrade the quality of the output signal. Hence, in this study, we introduce a method by combining the MMF and WTto overcome the shortcomings of both existing methods. To demonstrate the effectiveness of the proposed method, artificial ECG signals containing a clinicalBW are used for numerical simulation, and we also create a realistic model of baseline wander to compare the proposed method with other state-of-the-art methods commonly used in the literature. /e results show that the BW suppression effect of the proposed method is better than that of the others. Also, the new method is capable of preserving the outline of the BW and avoiding waveform distortions caused by the morphology filter, thereby obtaining an enhanced quality of ECG

    Research on Baseline Wander Removal and QRS Detection in Automated Analysis of Computerized Electrocardiogram

    Get PDF
    目前,计算机化心电图自动分析是一个热门的研究领域。它正在使心电仪器变得越来越智能,从而带来了心脏疾病诊断、监护、防控等方面的变革。但是这一领域的进一步发展正受到两个方面因素的制约:⑴心电图在采集的过程中通常会受到各种噪声的干扰;⑵缺少可靠的、稳定的算法来准确检测出心电图上的各个特征点。 因此,本文将围绕两个问题展开研究:⑴滤除心电图信号中最普遍的一种噪声——基线漂移;⑵检测心电图信号中最显著的成分波——QRS波群。这两项研究是心电图自动分析技术中最重要的工作。本文的主要研究工作及创新点归纳如下: 1、提出了基于离散余弦变换的算法以滤除心电图信号中的基线漂移。基线漂移是心电图信号中最...Currently, automated analysis of computerized electrocardiogram (ECG) is an active area of research. It is making the ECG equipments more and more intelligent, therefore evoking revolution in different aspects including cardiac disease diagnosis, cardiac disease monitoring, cardiac disease prevention and control, etc. However, the further development of this area is being restricted by two factors...学位:工程硕士院系专业:信息科学与技术学院智能科学与技术系_计算机技术学号:3152009115283

    Semiparametric curve alignment and shift density estimation for biological data

    Full text link
    Assume that we observe a large number of curves, all of them with identical, although unknown, shape, but with a different random shift. The objective is to estimate the individual time shifts and their distribution. Such an objective appears in several biological applications like neuroscience or ECG signal processing, in which the estimation of the distribution of the elapsed time between repetitive pulses with a possibly low signal-noise ratio, and without a knowledge of the pulse shape is of interest. We suggest an M-estimator leading to a three-stage algorithm: we split our data set in blocks, on which the estimation of the shifts is done by minimizing a cost criterion based on a functional of the periodogram; the estimated shifts are then plugged into a standard density estimator. We show that under mild regularity assumptions the density estimate converges weakly to the true shift distribution. The theory is applied both to simulations and to alignment of real ECG signals. The estimator of the shift distribution performs well, even in the case of low signal-to-noise ratio, and is shown to outperform the standard methods for curve alignment.Comment: 30 pages ; v5 : minor changes and correction in the proof of Proposition 3.

    Removal of artifacts from electrocardiogram

    Get PDF
    The electrocardiogram is the recording of the electrical potential of heart versus time. The analysis of ECG signal has great importance in the detection of cardiac abnormalities. The electrocardiographic signals are often contaminated by noise from diverse sources. Noises that commonly disturb the basic electrocardiogram are power line interference, instrumentation noise, external electromagnetic field interference, noise due to random body movements and respirational movements. These noises can be classified according to their frequency content. It is essential to reduce these disturbances in ECG signal to improve accuracy and reliability. Different types of adaptive and non-adaptive digital filters have been proposed to remove these noises. In this thesis, window based FIR filters, adaptive filters and wavelet filter bank are applied to remove the noises. Performances of the filters are compared based on the PSNR values. It is difficult to apply filters with fixed filter coefficients to reduce the instrumentation noise, because the time varying behaviour of this noise is not exactly known. Adaptive filter technique is required to overcome this problem, as the filter coefficients can be varied to track the dynamic variations of the signals. In wavelet transform, a signal is analyzed and expressed as a linear combination of the summation of the product of the wavelet coefficients and mother wavelet. The wavelet decomposition offers an excellent resolution both in time and frequency domain. Better estimation of the amplitudes is also obtained in wavelet based denoising

    Identification of cardiac signals in ambulatory ECG data

    Get PDF
    The Electrocardiogram (ECG) is the primary tool for monitoring heart function. ECG signals contain vital information about the heart which informs diagnosis and treatment of cardiac conditions. The diagnosis of many cardiac arrhythmias require long term and continuous ECG data, often while the participant engages in activity. Wearable ambulatory ECG (AECG) systems, such as the common Holter system, allow heart monitoring for hours or days. The technological trajectory of AECG systems aims towards continuous monitoring during a wide range of activities with data processed locally in real time and transmitted to a monitoring centre for further analysis. Furthermore, hierarchical decision systems will allow wearable systems to produce alerts or even interventions. These functions could be integrated into smartphones.A fundamental limitation of this technology is the ability to identify heart signal characteristics in ECG signals contaminated with high amplitude and non-stationary noise. Noise processing become more severe as activity levels increase, and this is also when many heart problems are present.This thesis focuses on the identification of heart signals in AECG data recorded during participant activity. In particular, it explored ECG filters to identify major heart conditions in noisy AECG data. Gold standard methods use Extended Kalman filters with extrapolation based on sum of Gaussian models. New methods are developed using linear Kalman filtering and extrapolation based on a sum of Principal Component basis signals. Unlike the gold standard methods, extrapolation is heartcycle by heartcycle. Several variants are explored where basic signals span one or two heartcycles, and applied to single or multi-channel ECG data.The proposed methods are extensively tested against standard databases or normal and abnormal ECG data and the performance is compared to gold standard methods. Two performance metrics are used: improvement in signal to noise ratio and the observability of clinically important features in the heart signal. In all tests the proposed method performs better, and often significantly better, than the gold standard methods. It is demonstrated that abnormal ECG signals can be identified in noisy AECG data

    Noise Reduction of 15-lead Electrocardiogram Signals Using Signal Processing Algorithms

    Get PDF
    In the research, a signal processing algorithm is proposed to reduce the noise and baseline wander in ECG spectra. The ECG spectra are first processed by symmetrical triangle smooth (can also be considered as a low pass filter) to reduce the noise, then a FIR high pass filter is applied to decrease the baseline wander. The ROC curves of the same classification test for myocardial infarction using ECG spectra processed by the standard and proposed method are plotted. The area under the curve can be improved up to 29.3%, which indicates the proposed ECG spectra can provide a more accuracy diagnostic result for myocardial infarction.Chemistry Departmen

    Biomedical Signal Transceivers

    Get PDF
    With the growing costs of healthcare, the need for mobile health monitoring devices is critical. A wireless transceiver provides a cost effective way to transmit biomedical signals to the various personal electronic devices, such as computers, cellular devices, and other mobile devices. Different kinds of biomedical signals can be processed and transmitted by these devices, including electroencephalograph (EEG), electrocardiograph (ECG), and electromyography (EMG). By utilizing wireless transmission, the user gains freedom to connect with fewer constraints to their personal devices to view and monitor their health condition. In this chapter, in the first few sections, we will introduce the reader with the basic design of the biomedical transceivers and some of the design issues. In the subsequent sections, we will be presenting design challenges for wireless transceivers, specially using a common wireless protocol Bluetooth. Furthermore, we will share our experience of implementing a biomedical transceiver for ECG signals and processing them. We conclude the discussion with current trends and future work

    Blind ECG Restoration by Operational Cycle-GANs

    Get PDF
    Objective: ECG recordings often suffer from a set of artifacts with varying types, severities, and durations, and this makes an accurate diagnosis by machines or medical doctors difficult and unreliable. Numerous studies have proposed ECG denoising; however, they naturally fail to restore the actual ECG signal corrupted with such artifacts due to their simple and naive noise model. In this pilot study, we propose a novel approach for blind ECG restoration using cycle-consistent generative adversarial networks (Cycle-GANs) where the quality of the signal can be improved to a clinical level ECG regardless of the type and severity of the artifacts corrupting the signal. Methods: To further boost the restoration performance, we propose 1D operational Cycle-GANs with the generative neuron model. Results: The proposed approach has been evaluated extensively using one of the largest benchmark ECG datasets from the China Physiological Signal Challenge (CPSC-2020) with more than one million beats. Besides the quantitative and qualitative evaluations, a group of cardiologists performed medical evaluations to validate the quality and usability of the restored ECG, especially for an accurate arrhythmia diagnosis. Significance: As a pioneer study in ECG restoration, the corrupted ECG signals can be restored to clinical level quality. Conclusion: By means of the proposed ECG restoration, the ECG diagnosis accuracy and performance can significantly improve.publishedVersionPeer reviewe

    On the Recognition of Emotion from Physiological Data

    Get PDF
    This work encompasses several objectives, but is primarily concerned with an experiment where 33 participants were shown 32 slides in order to create ‗weakly induced emotions‘. Recordings of the participants‘ physiological state were taken as well as a self report of their emotional state. We then used an assortment of classifiers to predict emotional state from the recorded physiological signals, a process known as Physiological Pattern Recognition (PPR). We investigated techniques for recording, processing and extracting features from six different physiological signals: Electrocardiogram (ECG), Blood Volume Pulse (BVP), Galvanic Skin Response (GSR), Electromyography (EMG), for the corrugator muscle, skin temperature for the finger and respiratory rate. Improvements to the state of PPR emotion detection were made by allowing for 9 different weakly induced emotional states to be detected at nearly 65% accuracy. This is an improvement in the number of states readily detectable. The work presents many investigations into numerical feature extraction from physiological signals and has a chapter dedicated to collating and trialing facial electromyography techniques. There is also a hardware device we created to collect participant self reported emotional states which showed several improvements to experimental procedure

    Analyse des ondes P et T des signaux ECG à l'aide de méthodes Bayésienne

    Get PDF
    Cette thèse a pour objet l étude de méthodes Bayésiennes pour l analyse des ondes P et T des signaux ECG. Différents modèles statistiques et des méthodes Bayésiennes associées sont proposés afin de réaliser la détection des ondes P et T et leur caractérisation (détermination du sommet et des limites des ondes ainsi que l estimation des formes d onde). Ces modèles prennent en compte des lois a priori pour les paramètres inconnus (les positions des ondes, les amplitudes et les coefficients de ces formes d'onde) associés aux signaux ECG. Ces lois a priori sont ensuite combinées avec la vraisemblance des données observées pour fournir les lois a posteriori des paramètres inconnus. En raison de la complexité des lois a posteriori obtenues, des méthodes de Monte Carlo par Chaînes de Markov sont proposées pour générer des échantillons distribués asymptotiquement suivant les lois d intérêt. Ces échantillons sont ensuite utilisés pour approcher les estimateurs Bayésiens classiques (MAP ou MMSE). D'autre part, pour profiter de la nature séquentielle du signal ECG, un modèle dynamique est proposé. Une méthode d'inférence Bayésienne similaire à celle développée précédemment et des méthodes de Monte Carlo séquentielles (SMC) sont ensuite étudiées pour ce modèle dynamique. Dans la dernière partie de ce travail, deux modèles Bayésiens introduits dans cette thèse sont adaptés pour répondre à un sujet de recherche clinique spécifique appelé détection de l'alternance des ondes T. Une des approches proposées a servi comme outil d'analyse dans un projet en collaboration avec St. Jude Medical, Inc et l'hôpital de Rangueil à Toulouse, qui vise à évaluer prospectivement la faisabilité de la détection des alternances des ondes T dans les signaux intracardiaques.This thesis studies Bayesian estimation/detection algorithms for P and T wave analysis in ECG signals. In this work, different statistical models and associated Bayesian methods are proposed to solve simultaneously the P and T wave delineation task (determination of the positions of the peaks and boundaries of the individual waves) and the waveform-estimation problem. These models take into account appropriate prior distributions for the unknown parameters (wave locations and amplitudes, and waveform coefficients). These prior distributions are combined with the likelihood of the observed data to provide the posterior distribution of the unknown parameters. Due to the complexity of the resulting posterior distributions, Markov chain Monte Carlo algorithms are proposed for (sample-based) detection/estimation. On the other hand, to take full advantage of the sequential nature of the ECG, a dynamic model is proposed under a similar Bayesian framework. Sequential Monte Carlo methods (SMC) are also considered for delineation and waveform estimation. In the last part of the thesis, two Bayesian models introduced in this thesis are adapted to address a specific clinical research problem referred to as T wave alternans (TWA) detection. One of the proposed approaches has served as an efficient analysis tool in the Endocardial T wave Alternans Study (ETWAS) project in collaboration with St. Jude Medical, Inc and Toulouse Rangueil Hospital. This project was devoted to prospectively assess the feasibility of TWA detection in repolarisation on EGM stored in ICD memories.TOULOUSE-INP (315552154) / SudocSudocFranceF
    corecore