903 research outputs found

    Virtual and Augmented Reality Techniques for Minimally Invasive Cardiac Interventions: Concept, Design, Evaluation and Pre-clinical Implementation

    Get PDF
    While less invasive techniques have been employed for some procedures, most intracardiac interventions are still performed under cardiopulmonary bypass, on the drained, arrested heart. The progress toward off-pump intracardiac interventions has been hampered by the lack of adequate visualization inside the beating heart. This thesis describes the development, assessment, and pre-clinical implementation of a mixed reality environment that integrates pre-operative imaging and modeling with surgical tracking technologies and real-time ultrasound imaging. The intra-operative echo images are augmented with pre-operative representations of the cardiac anatomy and virtual models of the delivery instruments tracked in real time using magnetic tracking technologies. As a result, the otherwise context-less images can now be interpreted within the anatomical context provided by the anatomical models. The virtual models assist the user with the tool-to-target navigation, while real-time ultrasound ensures accurate positioning of the tool on target, providing the surgeon with sufficient information to ``see\u27\u27 and manipulate instruments in absence of direct vision. Several pre-clinical acute evaluation studies have been conducted in vivo on swine models to assess the feasibility of the proposed environment in a clinical context. Following direct access inside the beating heart using the UCI, the proposed mixed reality environment was used to provide the necessary visualization and navigation to position a prosthetic mitral valve on the the native annulus, or to place a repair patch on a created septal defect in vivo in porcine models. Following further development and seamless integration into the clinical workflow, we hope that the proposed mixed reality guidance environment may become a significant milestone toward enabling minimally invasive therapy on the beating heart

    Computer Vision Techniques for Transcatheter Intervention

    Get PDF
    Minimally invasive transcatheter technologies have demonstrated substantial promise for the diagnosis and treatment of cardiovascular diseases. For example, TAVI is an alternative to AVR for the treatment of severe aortic stenosis and TAFA is widely used for the treatment and cure of atrial fibrillation. In addition, catheter-based IVUS and OCT imaging of coronary arteries provides important information about the coronary lumen, wall and plaque characteristics. Qualitative and quantitative analysis of these cross-sectional image data will be beneficial for the evaluation and treatment of coronary artery diseases such as atherosclerosis. In all the phases (preoperative, intraoperative, and postoperative) during the transcatheter intervention procedure, computer vision techniques (e.g., image segmentation, motion tracking) have been largely applied in the field to accomplish tasks like annulus measurement, valve selection, catheter placement control, and vessel centerline extraction. This provides beneficial guidance for the clinicians in surgical planning, disease diagnosis, and treatment assessment. In this paper, we present a systematical review on these state-of-the-art methods.We aim to give a comprehensive overview for researchers in the area of computer vision on the subject of transcatheter intervention. Research in medical computing is multi-disciplinary due to its nature, and hence it is important to understand the application domain, clinical background, and imaging modality so that methods and quantitative measurements derived from analyzing the imaging data are appropriate and meaningful. We thus provide an overview on background information of transcatheter intervention procedures, as well as a review of the computer vision techniques and methodologies applied in this area

    4D FLOW CMR in congenital heart disease

    Get PDF
    This thesis showed that the use of a cloud-based reconstruction applicationwith advanced eddy currents correction, integrated with interactiveimaging evaluation tools allowed for remote visualization and interpretationof 4D flow data and that was sufficient for gross visualizationof aortic valve regurgitation. Further, this thesis demonstrated that bulkflow and pulmonary regurgitation can be accurately quantified using 4Dflow imaging analyzed. Peak systolic velocity over the pulmonary valvemay be underestimated. However, the measurement of peak systolicvelocity can be optimized if measured at the level of highest velocity inthe pulmonary artery. Also correlated against invasive measurements (inan animal model), this thesis shows that aorta flow and pulmonary flowcan be accurately and simultaneously measured by 4D flow MRI.When applied in clinical practice, 4D flow has extra advantages, of beingable to visualize flow pattern, vorticity and to predict aortic growth. InASD patients it can measure shunt volume directly following the septumframe by frame. In Fontan patients in can visualize better than standardMRI the Fontan circuit and it can measure flow at multiple points alongthe Fontan circuit. We observed in our Fontan population that shunt lesionswere very common, most of the time via veno-venous collaterals.Further using advanced computations, we showed that WSS angle wasthe only independent predictor of aortic growth in BAV patients. We alsoshowed the feasibility of GLS analysis on 4D flow MRI and presented anintegrative approach in which flow and functional data are acquired inone sequence.From the technical point of view, 4D flow MRI has proved to complementthe traditional components of the standard cardiac MR exams, enablingin-depth insights into hemodynamics. At this moment it proved its addedvalue, but in most of the cases it is not able yet to replace the standardexam. This is still due to long scanning times and relatively longpost-processing times.<br/

    4D FLOW CMR in congenital heart disease

    Get PDF
    This thesis showed that the use of a cloud-based reconstruction applicationwith advanced eddy currents correction, integrated with interactiveimaging evaluation tools allowed for remote visualization and interpretationof 4D flow data and that was sufficient for gross visualizationof aortic valve regurgitation. Further, this thesis demonstrated that bulkflow and pulmonary regurgitation can be accurately quantified using 4Dflow imaging analyzed. Peak systolic velocity over the pulmonary valvemay be underestimated. However, the measurement of peak systolicvelocity can be optimized if measured at the level of highest velocity inthe pulmonary artery. Also correlated against invasive measurements (inan animal model), this thesis shows that aorta flow and pulmonary flowcan be accurately and simultaneously measured by 4D flow MRI.When applied in clinical practice, 4D flow has extra advantages, of beingable to visualize flow pattern, vorticity and to predict aortic growth. InASD patients it can measure shunt volume directly following the septumframe by frame. In Fontan patients in can visualize better than standardMRI the Fontan circuit and it can measure flow at multiple points alongthe Fontan circuit. We observed in our Fontan population that shunt lesionswere very common, most of the time via veno-venous collaterals.Further using advanced computations, we showed that WSS angle wasthe only independent predictor of aortic growth in BAV patients. We alsoshowed the feasibility of GLS analysis on 4D flow MRI and presented anintegrative approach in which flow and functional data are acquired inone sequence.From the technical point of view, 4D flow MRI has proved to complementthe traditional components of the standard cardiac MR exams, enablingin-depth insights into hemodynamics. At this moment it proved its addedvalue, but in most of the cases it is not able yet to replace the standardexam. This is still due to long scanning times and relatively longpost-processing times.<br/

    Development of a Surgical Assistance System for Guiding Transcatheter Aortic Valve Implantation

    Get PDF
    Development of image-guided interventional systems is growing up rapidly in the recent years. These new systems become an essential part of the modern minimally invasive surgical procedures, especially for the cardiac surgery. Transcatheter aortic valve implantation (TAVI) is a recently developed surgical technique to treat severe aortic valve stenosis in elderly and high-risk patients. The placement of stented aortic valve prosthesis is crucial and typically performed under live 2D fluoroscopy guidance. To assist the placement of the prosthesis during the surgical procedure, a new fluoroscopy-based TAVI assistance system has been developed. The developed assistance system integrates a 3D geometrical aortic mesh model and anatomical valve landmarks with live 2D fluoroscopic images. The 3D aortic mesh model and landmarks are reconstructed from interventional angiographic and fluoroscopic C-arm CT system, and a target area of valve implantation is automatically estimated using these aortic mesh models. Based on template-based tracking approach, the overlay of visualized 3D aortic mesh model, landmarks and target area of implantation onto fluoroscopic images is updated by approximating the aortic root motion from a pigtail catheter motion without contrast agent. A rigid intensity-based registration method is also used to track continuously the aortic root motion in the presence of contrast agent. Moreover, the aortic valve prosthesis is tracked in fluoroscopic images to guide the surgeon to perform the appropriate placement of prosthesis into the estimated target area of implantation. An interactive graphical user interface for the surgeon is developed to initialize the system algorithms, control the visualization view of the guidance results, and correct manually overlay errors if needed. Retrospective experiments were carried out on several patient datasets from the clinical routine of the TAVI in a hybrid operating room. The maximum displacement errors were small for both the dynamic overlay of aortic mesh models and tracking the prosthesis, and within the clinically accepted ranges. High success rates of the developed assistance system were obtained for all tested patient datasets. The results show that the developed surgical assistance system provides a helpful tool for the surgeon by automatically defining the desired placement position of the prosthesis during the surgical procedure of the TAVI.Die Entwicklung bildgeführter interventioneller Systeme wächst rasant in den letzten Jahren. Diese neuen Systeme werden zunehmend ein wesentlicher Bestandteil der technischen Ausstattung bei modernen minimal-invasiven chirurgischen Eingriffen. Diese Entwicklung gilt besonders für die Herzchirurgie. Transkatheter Aortenklappen-Implantation (TAKI) ist eine neue entwickelte Operationstechnik zur Behandlung der schweren Aortenklappen-Stenose bei alten und Hochrisiko-Patienten. Die Platzierung der Aortenklappenprothese ist entscheidend und wird in der Regel unter live-2D-fluoroskopischen Bildgebung durchgeführt. Zur Unterstützung der Platzierung der Prothese während des chirurgischen Eingriffs wurde in dieser Arbeit ein neues Fluoroskopie-basiertes TAKI Assistenzsystem entwickelt. Das entwickelte Assistenzsystem überlagert eine 3D-Geometrie des Aorten-Netzmodells und anatomischen Landmarken auf live-2D-fluoroskopische Bilder. Das 3D-Aorten-Netzmodell und die Landmarken werden auf Basis der interventionellen Angiographie und Fluoroskopie mittels eines C-Arm-CT-Systems rekonstruiert. Unter Verwendung dieser Aorten-Netzmodelle wird das Zielgebiet der Klappen-Implantation automatisch geschätzt. Mit Hilfe eines auf Template Matching basierenden Tracking-Ansatzes wird die Überlagerung des visualisierten 3D-Aorten-Netzmodells, der berechneten Landmarken und der Zielbereich der Implantation auf fluoroskopischen Bildern korrekt überlagert. Eine kompensation der Aortenwurzelbewegung erfolgt durch Bewegungsverfolgung eines Pigtail-Katheters in Bildsequenzen ohne Kontrastmittel. Eine starrere Intensitätsbasierte Registrierungsmethode wurde verwendet, um kontinuierlich die Aortenwurzelbewegung in Bildsequenzen mit Kontrastmittelgabe zu detektieren. Die Aortenklappenprothese wird in die fluoroskopischen Bilder eingeblendet und dient dem Chirurg als Leitfaden für die richtige Platzierung der realen Prothese. Eine interaktive Benutzerschnittstelle für den Chirurg wurde zur Initialisierung der Systemsalgorithmen, zur Steuerung der Visualisierung und für manuelle Korrektur eventueller Überlagerungsfehler entwickelt. Retrospektive Experimente wurden an mehreren Patienten-Datensätze aus der klinischen Routine der TAKI in einem Hybrid-OP durchgeführt. Hohe Erfolgsraten des entwickelten Assistenzsystems wurden für alle getesteten Patienten-Datensätze erzielt. Die Ergebnisse zeigen, dass das entwickelte chirurgische Assistenzsystem ein hilfreiches Werkzeug für den Chirurg bei der Platzierung Position der Prothese während des chirurgischen Eingriffs der TAKI bietet

    Artificial intelligence and automation in valvular heart diseases

    Get PDF
    Artificial intelligence (AI) is gradually changing every aspect of social life, and healthcare is no exception. The clinical procedures that were supposed to, and could previously only be handled by human experts can now be carried out by machines in a more accurate and efficient way. The coming era of big data and the advent of supercomputers provides great opportunities to the development of AI technology for the enhancement of diagnosis and clinical decision-making. This review provides an introduction to AI and highlights its applications in the clinical flow of diagnosing and treating valvular heart diseases (VHDs). More specifically, this review first introduces some key concepts and subareas in AI. Secondly, it discusses the application of AI in heart sound auscultation and medical image analysis for assistance in diagnosing VHDs. Thirdly, it introduces using AI algorithms to identify risk factors and predict mortality of cardiac surgery. This review also describes the state-of-the-art autonomous surgical robots and their roles in cardiac surgery and intervention

    CNN-based Landmark Detection in Cardiac CTA Scans

    Full text link
    Fast and accurate anatomical landmark detection can benefit many medical image analysis methods. Here, we propose a method to automatically detect anatomical landmarks in medical images. Automatic landmark detection is performed with a patch-based fully convolutional neural network (FCNN) that combines regression and classification. For any given image patch, regression is used to predict the 3D displacement vector from the image patch to the landmark. Simultaneously, classification is used to identify patches that contain the landmark. Under the assumption that patches close to a landmark can determine the landmark location more precisely than patches farther from it, only those patches that contain the landmark according to classification are used to determine the landmark location. The landmark location is obtained by calculating the average landmark location using the computed 3D displacement vectors. The method is evaluated using detection of six clinically relevant landmarks in coronary CT angiography (CCTA) scans: the right and left ostium, the bifurcation of the left main coronary artery (LM) into the left anterior descending and the left circumflex artery, and the origin of the right, non-coronary, and left aortic valve commissure. The proposed method achieved an average Euclidean distance error of 2.19 mm and 2.88 mm for the right and left ostium respectively, 3.78 mm for the bifurcation of the LM, and 1.82 mm, 2.10 mm and 1.89 mm for the origin of the right, non-coronary, and left aortic valve commissure respectively, demonstrating accurate performance. The proposed combination of regression and classification can be used to accurately detect landmarks in CCTA scans.Comment: This work was submitted to MIDL 2018 Conferenc
    corecore