14,142 research outputs found

    Personal solar UV exposure measurements employing modified polysulphone with an extended dynamic range

    Get PDF
    Polysulphone dosimeters using a simple to use filter have been developed and tested to provide an extended dynamic measurement range of personal solar UV exposures over an extended period (3 to 6 days). At a Southern Hemisphere subtropical site (27.68S, 151.98E), the dynamic range of the filtered polysulphone allowed measurements of erythemal exposures to approximately 100 minimum erythemal dose (MED) for a change in optical absorbance at 330 nm (DA330) of 0.35. In comparison, unfiltered polysulphone dosimeters were exposed to approximately 8 MED for the same DA330. The error associated with the use of the filtered polysulphone dosimeters is of the order of 615%, compared with 610% of the unfiltered variety. The developed filtered polysulphone dosimeter system allowed the measurement of erythemal UV exposures over 3 to 6 days at a subtropical site without the need to replace the dosimeters because of saturation. The results show that longer-term measurement programs of personal solar UV have been made more feasible with the use of these polysulphone dosimeters with an extended dynamic range compared with unfiltered polysulphone dosimeters

    Selection and use of TLDS for high precision NERVA shielding measurements

    Get PDF
    An experimental evaluation of thermoluminescent dosimeters was performed in order to select high precision dosimeters for a study whose purpose is to measure gamma streaming through the coolant passages of a simulated flight type internal NERVA reactor shield. Based on this study, the CaF2 chip TLDs are the most reproducible dosimeters with reproducibility generally within a few percent, but none of the TLDs tested met the reproducibility criterion of plus or minus 2%

    Solar UV radiation measurements with polysulphone

    Get PDF
    [Abstract]: In order to optimize the UV exposure of humans, an understanding of the complex solar UV environment is necessary. Dosimeters based on either biological or chemical UV dosimeters have been developed and are a powerful tool in the research on the solar UV environment. Polysulphone which has achieved wide spread use as a dosimeter in research on UV exposures resulting from the sun or artificial sources is discussed

    Surface and buildup region dose measurements with Markus parallel-plate ionization chamber, Gafchromic EBT3 film and MOSFET detector for high energy photon beams

    Full text link
    The aim of the study was to investigate surface and buildup region doses for 6MV and 15MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film, and MOSFET detector for different field sizes and beam angles. The measurements were made in a water equivalent solid phantom at the surface and in the buildup region of the 6MV and 15MV photon beams at 100 cm source-detector distance for 5 x 5, 10 x 10, and 20 x 20 cm2 field sizes and 0, 30, 60, and 80 beam angles. The surface doses using 6MVphoton beams for 10 x 10 cm2 field size were found to be 20.3%, 18.8%, and 25.5% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface doses using 15MV photon beams for 10 x 10 cm2 field size were found to be 14.9%, 13.4%, and 16.4% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface dose increased with field size for all dosimeters. As the angle of the incident radiation beam became more oblique, the surface dose increased. The effective measurement depths of dosimeters vary; thus, the results of the measurements could be different. This issue can lead to mistakes at surface and buildup dosimetry and must be taken into account

    Report of IRPA task group on the impact of the eye lens dose limits

    Get PDF
    In 2012 IRPA established a task group (TG) to identify key issues in the implementation of the revised eye lens dose limit. The TG reported its conclusions in 2013. In January 2015, IRPA asked the TG to review progress with the implementation of the recommendations from the early report and to collate current practitioner experience. This report presents the results of a survey on the view of the IRPA professionals on the new limit to the lens of the eye and on the wider issue of tissue reactions. Recommendations derived from the survey are presented. This report was approved by IRPA Executive Council on 31 January 2017

    Experimental active and passive dosimetry systems for the NASA Skylab program

    Get PDF
    Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis

    Fricke and polymer gel 2D dosimetry validation using Monte Carlo simulation

    Get PDF
    Complexity in modern radiotherapy treatments demands advanced dosimetry systems for quality control. These systems must have several characteristics, such as high spatial resolution, tissue equivalence, three-dimensional resolution, and dose-integrating capabilities. In this scenario, gel dosimetry has proved to be a very promising option for quality assurance. In this study, the feasibility of Fricke and polymer gel dosimeters suitably shaped in form of thin layers and optically analyzed by visible light transmission imaging has been investigated for quality assurance in external radiotherapy. Dosimeter irradiation was carried out with a 6-MV photon beam (CLINAC 600C). The analysis of the irradiated dosimeters was done using two-dimensional optical transmission images. These dosimeters were compared with a treatment plan system using Monte Carlo simulations as a reference by means of a gamma test with parameters of 1 mm and 2%. Results show very good agreement between the different dosimetric systems: in the worst-case scenario, 98% of the analyzed points meet the test quality requirements. Therefore, gel dosimetry may be considered as a potential tool for the validation of other dosimetric systems.Fil: Vedelago, José Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad Nacional de Córdoba; ArgentinaFil: Chacón Obando, D.. Universidad Nacional. Physics Department; Costa Rica. Universidad Nacional de Córdoba; ArgentinaFil: Malano, Francisco Mauricio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad Nacional de Córdoba; ArgentinaFil: Conejeros, R.. Servicio de Radioterapia, Icos. Temuco, Chile;Fil: Figueroa, R.. Universidad de la Frontera; ChileFil: Garcia, D.. Servicio de Imagenes por Resonancia Magnética; ChileFil: González, G.. Servicio de Imagenes por Resonancia Magnética; ChileFil: Romero, Marcelo Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto Multidisciplinario de Biología Vegetal. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Instituto Multidisciplinario de Biología Vegetal; Argentina. Universidad Nacional de Córdoba; ArgentinaFil: Santibañez, M.. Servicio de Imagenes por Resonancia Magnética; ChileFil: Strumia, Miriam Cristina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto Multidisciplinario de Biología Vegetal. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Instituto Multidisciplinario de Biología Vegetal; ArgentinaFil: Velásquez, J.. Servicio de Radioterapia; ChileFil: Mattea, Facundo. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Departamento de Química Orgánica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Valente, M.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad de La Frontera. Departamento de Ciencias Físicas; Chil
    corecore