65,383 research outputs found

    Dynamics of conduction blocks in a model of paced cardiac tissue

    Full text link
    We study numerically the dynamics of conduction blocks using a detailed electrophysiological model. We find that this dynamics depends critically on the size of the paced region. Small pacing regions lead to stationary conduction blocks while larger pacing regions can lead to conduction blocks that travel periodically towards the pacing region. We show that this size-dependence dynamics can lead to a novel arrhythmogenic mechanism. Furthermore, we show that the essential phenomena can be captured in a much simpler coupled-map model.Comment: 8 pages 6 figure

    Skylab IMSS checklist application study for emergency medical care

    Get PDF
    A manual is presented that provides basic technical documentation to support the operation and utilization of the Portable Ambulance Module (PAM) in the field. The PAM is designed to be used for emergency resuscitation and victim monitoring. The functions of all the controls, displays, and stowed equipment of the unit are defined. Supportive medical and physiological data in those areas directly related to the uses of the PAM unit are presented

    Dc Shock Simulator

    Full text link
    Defibrillators are electronic devices that carry shock electrical signals (pulses) to the heart muscle to maintain myocardial depolarization that is undergoing cardiac fibrillation (ventricular fibrillation or atrial fibrillation) (Bronzino, 2000). There are several conditions that must be met for the occurrence of shock processes including shock time, energy to be provided, patient and operator safety. In this defibrillator the use of selectors / energy selection is linear in the range 1-30 Joules with the use of tools at 10, 15, 20, 25, 30 Joules. The energy will then be discarded or given to the patient via a paddle when pressed the Discharge / shock button. The result of the signal given to the patient is monophasic. This study used a pre-experimental type with a One Group post test design research design. Measurements were made 5 times the volt meter at the test points determined by the compiler

    Index to nasa tech briefs, issue number 2

    Get PDF
    Annotated bibliography on technological innovations in NASA space program

    An evaluation of planarity of the spatial QRS loop by three dimensional vectorcardiography: its emergence and loss

    Get PDF
    Aims: To objectively characterize and mathematically justify the observation that vectorcardiographic QRS loops in normal individuals are more planar than those from patients with ST elevation myocardial infarction (STEMI). Methods: Vectorcardiograms (VCGs) were constructed from three simultaneously recorded quasi-orthogonal leads, I, aVF and V2 (sampled at 1000 samples/s). The planarity of these QRS loops was determined by fitting a surface to each loop. Goodness of fit was expressed in numerical terms. Results: 15 healthy individuals aged 35–65 years (73% male) and 15 patients aged 45–70 years (80% male) with diagnosed acute STEMI were recruited. The spatial-QRS loop was found to lie in a plane in normal controls. In STEMI patients, this planarity was lost. Calculation of goodness of fit supported these visual observations. Conclusions: The degree of planarity of the VCG loop can differentiate healthy individuals from patients with STEMI. This observation is compatible with our basic understanding of the electrophysiology of the human heart

    Electrocardiogram (ECG/EKG) using FPGA

    Get PDF
    FPGAs (Field Programmable Gate Arrays) are finding wide acceptance in medical systems for their ability for rapid prototyping of a concept that requires hardware/software co-design, for performing custom processing in parallel at high data rates and be programmed in the field after manufacturing. Based on the market demand, the FPGA design can be changed and no new hardware needs to be purchased as was the case with ASICs (Application Specific Integrated Circuit) and CPLDs (Complex Programmable Logic Device). Medical companies can now move over to FPGAs saving cost and delivering highly-efficient upgradable systems. ECG (Electrocardiogram) is considered to be a must have feature for a medical diagnostic imaging system. This project attempts at implementing ECG heart-rate computation in an FPGA. This project gave me exposure to hardware engineering, learning about the low level chips like Atmel UC3A3256 micro-controller on an Atmel EVK1105 board which is used as a simulator for generating the ECG signal, the operational amplifiers for amplifying and level-shifting the ECG signal, the A/D converter chip for analog to digital conversion of the ECG signal, the internal workings of FPGA, how different hardware components communicate with each other on the system and finally some signal processing to calculate the heart rate value from the ECG signal

    Technology applications

    Get PDF
    A summary of NASA Technology Utilization programs for the period of 1 December 1971 through 31 May 1972 is presented. An abbreviated description of the overall Technology Utilization Applications Program is provided as a background for the specific applications examples. Subjects discussed are in the broad headings of: (1) cancer, (2) cardiovascular disease, (2) medical instrumentation, (4) urinary system disorders, (5) rehabilitation medicine, (6) air and water pollution, (7) housing and urban construction, (8) fire safety, (9) law enforcement and criminalistics, (10) transportation, and (11) mine safety

    Characterisation of re-entrant circuit (or rotational activity) in vitro using the HL1-6 myocyte cell line

    Get PDF
    Fibrillation is the most common arrhythmia observed in clinical practice. Understanding of the mechanisms underlying its initiation and maintenance remains incomplete. Functional re-entries are potential drivers of the arrhythmia. Two main concepts are still debated, the “leading circle” and the “spiral wave or rotor” theories. The homogeneous subclone of the HL1 atrial-derived cardiomyocyte cell line, HL1-6, spontaneously exhibits re-entry on a microscopic scale due to its slow conduction velocity and the presence of triggers, making it possible to examine re-entry at the cellular level. We therefore investigated the re-entry cores in cell monolayers through the use of fluorescence optical mapping at high spatiotemporal resolution in order to obtain insights into the mechanisms of re-entry. Re-entries in HL1-6 myocytes required at least two triggers and a minimum colony area to initiate (3.5 to 6.4 mm2). After electrical activity was completely stopped and re-started by varying the extracellular K+ concentration, re-entries never returned to the same location while 35% of triggers re-appeared at the same position. A conduction delay algorithm also allows visualisation of the core of the re-entries. This work has revealed that the core of re-entries is conduction blocks constituted by lines and/or groups of cells rather than the round area assumed by the other concepts of functional re-entry. This highlights the importance of experimentation at the microscopic level in the study of re-entry mechanisms

    Biomedical ultrasonoscope

    Get PDF
    The combination of a "C" mode scan electronics in a portable, battery powered biomedical ultrasonoscope having "A" and "M" mode scan electronics, the latter including a clock generator for generating clock pulses, a cathode ray tube having X, Y and Z axis inputs, a sweep generator connected between the clock generator and the X axis input of the cathode ray tube for generating a cathode ray sweep signal synchronized by the clock pulses, and a receiver adapted to be connected to the Z axis input of the cathode ray tube. The "C" mode scan electronics comprises a plurality of transducer elements arranged in a row and adapted to be positioned on the skin of the patient's body for converting a pulsed electrical signal to a pulsed ultrasonic signal, radiating the ultrasonic signal into the patient's body, picking up the echoes reflected from interfaces in the patient's body and converting the echoes to electrical signals; a plurality of transmitters, each transmitter being coupled to a respective transducer for transmitting a pulsed electrical signal thereto and for transmitting the converted electrical echo signals directly to the receiver, a sequencer connected between the clock generator and the plurality of transmitters and responsive to the clock pulses for firing the transmitters in cyclic order; and a staircase voltage generator connected between the clock generator and the Y axis input of the cathode ray tube for generating a staircase voltage having steps synchronized by the clock pulses
    corecore