3,992 research outputs found
Modelling Aspects of Planar Multi-Mode Antennas for Direction-of-Arrival Estimation
Multi-mode antennas are an alternative to classical antenna arrays, and hence
a promising emerging sensor technology for a vast variety of applications in
the areas of array signal processing and digital communications. An unsolved
problem is to describe the radiation pattern of multi-mode antennas in closed
analytic form based on calibration measurements or on electromagnetic field
(EMF) simulation data. As a solution, we investigate two modeling methods: One
is based on the array interpolation technique (AIT), the other one on wavefield
modeling (WM). Both methods are able to accurately interpolate quantized EMF
data of a given multi-mode antenna, in our case a planar four-port antenna
developed for the 6-8.5 GHz range. Since the modeling methods inherently depend
on parameter sets, we investigate the influence of the parameter choice on the
accuracy of both models. Furthermore, we evaluate the impact of modeling errors
for coherent maximum-likelihood direction-of-arrival (DoA) estimation given
different model parameters. Numerical results are presented for a single
polarization component. Simulations reveal that the estimation bias introduced
by model errors is subject to the chosen model parameters. Finally, we provide
optimized sets of AIT and WM parameters for the multi-mode antenna under
investigation. With these parameter sets, EMF data samples can be reproduced in
interpolated form with high angular resolution
Space Time MUSIC: Consistent Signal Subspace Estimation for Wide-band Sensor Arrays
Wide-band Direction of Arrival (DOA) estimation with sensor arrays is an
essential task in sonar, radar, acoustics, biomedical and multimedia
applications. Many state of the art wide-band DOA estimators coherently process
frequency binned array outputs by approximate Maximum Likelihood, Weighted
Subspace Fitting or focusing techniques. This paper shows that bin signals
obtained by filter-bank approaches do not obey the finite rank narrow-band
array model, because spectral leakage and the change of the array response with
frequency within the bin create \emph{ghost sources} dependent on the
particular realization of the source process. Therefore, existing DOA
estimators based on binning cannot claim consistency even with the perfect
knowledge of the array response. In this work, a more realistic array model
with a finite length of the sensor impulse responses is assumed, which still
has finite rank under a space-time formulation. It is shown that signal
subspaces at arbitrary frequencies can be consistently recovered under mild
conditions by applying MUSIC-type (ST-MUSIC) estimators to the dominant
eigenvectors of the wide-band space-time sensor cross-correlation matrix. A
novel Maximum Likelihood based ST-MUSIC subspace estimate is developed in order
to recover consistency. The number of sources active at each frequency are
estimated by Information Theoretic Criteria. The sample ST-MUSIC subspaces can
be fed to any subspace fitting DOA estimator at single or multiple frequencies.
Simulations confirm that the new technique clearly outperforms binning
approaches at sufficiently high signal to noise ratio, when model mismatches
exceed the noise floor.Comment: 15 pages, 10 figures. Accepted in a revised form by the IEEE Trans.
on Signal Processing on 12 February 1918. @IEEE201
Ultrasound localization microscopy to image and assess microvasculature in a rat kidney.
The recent development of ultrasound localization microscopy, where individual microbubbles (contrast agents) are detected and tracked within the vasculature, provides new opportunities for imaging the vasculature of entire organs with a spatial resolution below the diffraction limit. In stationary tissue, recent studies have demonstrated a theoretical resolution on the order of microns. In this work, single microbubbles were localized in vivo in a rat kidney using a dedicated high frame rate imaging sequence. Organ motion was tracked by assuming rigid motion (translation and rotation) and appropriate correction was applied. In contrast to previous work, coherence-based non-linear phase inversion processing was used to reject tissue echoes while maintaining echoes from very slowly moving microbubbles. Blood velocity in the small vessels was estimated by tracking microbubbles, demonstrating the potential of this technique to improve vascular characterization. Previous optical studies of microbubbles in vessels of approximately 20 microns have shown that expansion is constrained, suggesting that microbubble echoes would be difficult to detect in such regions. We therefore utilized the echoes from individual MBs as microscopic sensors of slow flow associated with such vessels and demonstrate that highly correlated, wideband echoes are detected from individual microbubbles in vessels with flow rates below 2 mm/s
- …