1,126 research outputs found

    Direct torque control of permanent magnet synchronous motors with non-sinusoidal back-EMF

    Get PDF
    This work presents the direct torque control (DTC) techniques, implemented in four- and six-switch inverter, for brushless dc (BLDC) motors with non-sinusoidal back- EMF using two and three-phase conduction modes. First of all, the classical direct torque control of permanent magnet synchronous motor (PMSM) with sinusoidal back-EMF is discussed in detail. Secondly, the proposed two-phase conduction mode for DTC of BLDC motors is introduced in the constant torque region. In this control scheme, only two phases conduct at any instant of time using a six-switch inverter. By properly selecting the inverter voltage space vectors of the two-phase conduction mode from a simple look-up table the desired quasi-square wave current is obtained. Therefore, it is possible to achieve DTC of a BLDC motor drive with faster torque response while the stator flux linkage amplitude is deliberately kept almost constant by ignoring the flux control in the constant torque region. Third, the avarege current controlled boost power factor correction (PFC) method is applied to the previously discussed proposed DTC of BLDC motor drive in the constant torque region. The test results verify that the proposed PFC for DTC of BLDC motor drive improves the power factor from 0.77 to about 0.9997 irrespective of the load. Fourth, the DTC technique for BLDC motor using four-switch inverter in the constant torque region is studied. For effective torque control in two phase conduction mode, a novel switching pattern incorporating the voltage vector look-up table is designed and implemented for four-switch inverter to produce the desired torque characteristics. As a result, it is possible to achieve two-phase conduction DTC of a BLDC motor drive using four-switch inverter with faster torque response due to the fact that the voltage space vectors are directly controlled.. Finally, the position sensorless direct torque and indirect flux control (DTIFC) of BLDC motor with non-sinusoidal back-EMF has been extensively investigated using three-phase conduction scheme with six-switch inverter. In this work, a novel and simple approach to achieve a low-frequency torque ripple-free direct torque control with maximum efficiency based on dq reference frame similar to permanent magnet synchronous motor (PMSM) drives is presented

    Fault tolerant model predictive control of three-phase permanent magnet synchronous motors

    Full text link
    A new fault tolerant model predictive control (FTMPC) strategy is proposed for three-phase magnetically isotropic permanent magnet synchronous motor (PMSM) with complete loss of one phase (LOP) or loss of one leg (LOL) of the inverter. The dynamic model of PMSM with LOP or LOL is derived in abc- System. The principle of FTMPC is investigated, its predictive model for remaining two stator phase currents is established after LOP or LOL occurs, and the flux estimator based on current model is employed in order to calculate the stator flux & its corresponding torque. Extra-leg extra-switch inverter is used as power unit. The PI controller is put to use for regulating rotor speed and generating reference torque. Dynamic responses of healthy MPC and unhealthy FTMPC for PMSM systems are given to compare their performance via simulation and some analysis is presented. The simulation results show that the proposed FTMPC strategy not only allows for continuous and disturbance-free operation of the unhealthy PMSM with LOP or LOL but also preserves satisfactory torque and speed control. And then the effectiveness of the proposed schemes in this paper is demonstrated

    Remedial Strategies of T-NPC Three-Level Asymmetric Six-Phase PMSM Drives Based on SVM-DTC

    Get PDF

    Implementation and Analysis of Direct Torque Control for Permanent Magnet Synchronous Motor Using Gallium Nitride based Inverter

    Get PDF
    Permanent magnet synchronous machines (PMSMs) attract considerable attention in various industrial applications, such as electric and hybrid electric vehicles, due to their high efficiency and high-power density. In this thesis, the mathematical model of PMSM and two popular control strategies, field-oriented control (FOC) and direct torque control (DTC), are analyzed and compared. The results demonstrated that the DTC has better dynamic response in comparison to FOC. Moreover, DTC can eliminate the use of position sensor, which will save the cost of the PMSM drive system. Therefore, this thesis focuses on the design and implementation of high-performance DTC for PMSMs with a Gallium Nitride (GaN) based high switching frequency motor drive. First, the characteristics and operation principles of a PMSM are introduced. Then, the mathematical models of a PMSM under different coordinate systems are investigated. Consequently, a PMSM model is developed based on the dq rotating reference frame and implemented in the MATLAB/Simulink for validation. Two advanced PMSM control strategies, FOC and DTC, are investigated and compared in terms of control performance through comprehensive simulation studies and the results demonstrate that DTC has better dynamic performance. Conventional DTC contributes to higher torque ripple in the PMSM due to the limited switching frequency in a conventional semiconductor-based motor drive, which inevitably deteriorates the drive performance. Therefore, this thesis aims to reduce the torque ripple in the DTC based PMSM drive by using the new generation wide bandgap switching devices. More specifically, DTC is improved by using the optimized space vector pulse width modulation strategy and a higher switching frequency contributed by the GaN based motor drive. Finally, the proposed DTC-SVM based PMSM control strategy is implemented on the digital signal processor (DSP) and evaluated on the laboratory GaN based PMSM drive. Both the simulation and experimental results show that the proposed improvement in the DTC can further improve the PMSM drive performance

    Fault Tolerant Power Converter Topologies for Sensor-less Speed Control of PMSM Drives

    Get PDF
    This paper exhibits a sensor-less speed control method based MRAS observer applied to a fault-tolerant PMSM drive system. So, this paper proposes a rapid method of fault switch detection in the power converters aiming to make sure the continuity of service even though the fault presence of an opening phase. In fact, the MRAS observer is used to replace the mechanical sensor and a redundant inverter leg is equally employed to replace the faulty leg. The proposed fast fault diagnosis method has the features of simple algorithm, independence of the transient states and being simply integrated without any additional sensors

    ADRC-based model predictive current control for PMSMs fed by three-phase four-switch inverters

    Full text link
    © 2016 IEEE.A novel automatic disturbances rejection control (ADRC)-based model predictive current control (MPCC) strategy is developed for permanent magnet synchronous motors (PMSMs) fed by three-phase four-switch inverters, an after-fault-topology for fault-tolerant three-phase six-switch inverters. The mathematical model of a PMSM fed by a three-phase four-switch inverter is built firstly. Then the ADRC and MPCC are respectively designed, with the former being used to realize disturbance estimation and disturbance compensation while the latter being used to reduce stator current ripple and improve the quality of the torque and speed control. The resultant ADRC-based MPCC PMSM fed by an unhealthy inverter has fault-tolerant effective with dynamical performance very close to an ADRC-based MPCC PMSM fed by a healthy inverter. On the other hand, compared with PI-based MPCC PMSM fed by an unhealthy inverter, it possesses better dynamical response behavior and stronger robustness as well as smaller THD index of three-phase stator current in the presence of variation of load torque. The simulation results validate the feasibility and effectiveness of the proposed scheme

    New Modulation Technique to Mitigate Common Mode Voltage Effects in Star-Connected Five-Phase AC Drives

    Get PDF
    Star-connected multiphase AC drives are being considered for electromovility applications such as electromechanical actuators (EMA), where high power density and fault tolerance is demanded. As for three-phase systems, common-mode voltage (CMV) is an issue for multiphase drives. CMV leads to shaft voltages between rotor and stator windings, generating bearing currents which accelerate bearing degradation and produce high electromagnetic interferences (EMI). CMV effects can be mitigated by using appropriate modulation techniques. Thus, this work proposes a new Hybrid PWM algorithm that effectively reduces CMV in five-phase AC electric drives, improving their reliability. All the mathematical background required to understand the proposal, i.e., vector transformations, vector sequences and calculation of analytical expressions for duty cycle determination are detailed. Additionally, practical details that simplify the implementation of the proposal in an FPGA are also included. This technique, HAZSL5M5-PWM, extends the linear range of the AZSL5M5-PWM modulation, providing a full linear range. Simulation results obtained in an accurate multiphase EMA model are provided, showing the validity of the proposed modulation approach.This work has been supported in part by the Government of the Basque Country within the fund for research groups of the Basque University system IT978-16 and in part by the Government of the Basque Country within the research program ELKARTEK as the project ENSOL (KK-2018/00040)

    Design and implementation of a loss optimization control for electric vehicle in-wheel permanent-magnet synchronous motor direct drive system

    Get PDF
    As a main driving force of electric vehicles (EVs), the losses of in-wheel permanent-magnet synchronous motor (PMSM) direct drive system can seriously affect the energy consumption of EVs. This paper proposes a loss optimization control strategy for in-wheel PMSM direct drive system of EVs which optimizes the losses of both the PMSM and the inverter. The proposed method adjusts the copper losses and iron losses by identifying the optimal flux-weakening current, which results in the PMSM achieving the lower losses in the whole operational range. Moreover there are strongly nonlinear characteristics for the power devices, this paper creates a nonlinear loss model for three-phase half-bridge inverters to obtain accurate inverter losses under space vector pulse width modulation (SVPWM). Based on the inverter loss model and double Fourier integral analysis theory, the PWM frequency is optimized by the control strategy in order to maximize the inverter efficiency without affecting the operational stability of the drive. The proposed loss optimization control strategy can quickly find the optimum flux-weakening current and PWM frequency, and as a result, significantly broaden the high efficiency area of the PMSM direct drive system. The effects of the aforementioned strategy are verified by both theoretical analysis and experimental results

    FPGA-based implementation of the back-EMF symmetric-threshold-tracking sensorless commutation method for brushless DC-machines

    Get PDF
    The operation of brushless DC permanent-magnet machines requires information of the rotor position to steer the semiconductor switches of the power-supply module which is commonly referred to as Brushless Commutation. Different sensorless techniques have been proposed to estimate the rotor position using current and voltage measurements of the machine. Detection of the back-electromotive force (EMF) zero-crossing moments is one of the methods most used to achieve sensorless control by predicting the commutation moments. Most of the techniques based on this phenomenon have the inherit disadvantage of an indirect detection of commutation moments. This is the result of the commutation moment occurring 30 electrical degrees after the zero-crossing of the induced back-emf in the unexcited phase. Often, the time difference between the zero crossing of the back-emf and the optimal current commutation is assumed constant. This assumption can be valid for steady-state operation, however a varying time difference should be taken into account during transient operation of the BLDC machine. This uncertainty degrades the performance of the drive during transients. To overcome this problem which improves the performance while keeping the simplicity of the back-emf zero-crossing detection method an enhancement is proposed. The proposed sensorless method operates parameterless in a way it uses none of the brushless dc-machine parameters. In this paper different aspects of experimental implementation of the new method as well as various aspects of the FPGA programming are discussed. Proposed control method is implemented within a Xilinx Spartan 3E XC3S500E board
    • …
    corecore