6,255 research outputs found
Respiratory organ motion in interventional MRI : tracking, guiding and modeling
Respiratory organ motion is one of the major challenges in interventional MRI, particularly in interventions with therapeutic ultrasound in the abdominal region. High-intensity focused ultrasound found an application in interventional MRI for noninvasive treatments of different abnormalities. In order to guide surgical and treatment interventions, organ motion imaging and modeling is commonly required before a treatment start. Accurate tracking of organ motion during various interventional MRI procedures is prerequisite for a successful outcome and safe therapy.
In this thesis, an attempt has been made to develop approaches using focused ultrasound which could be used in future clinically for the treatment of abdominal organs, such as the liver and the kidney. Two distinct methods have been presented with its ex vivo and in vivo treatment results. In the first method, an MR-based pencil-beam navigator has been used to track organ motion and provide the motion information for acoustic focal point steering, while in the second approach a hybrid imaging using both ultrasound and magnetic resonance imaging was combined for advanced guiding capabilities.
Organ motion modeling and four-dimensional imaging of organ motion is increasingly required before the surgical interventions. However, due to the current safety limitations and hardware restrictions, the MR acquisition of a time-resolved sequence of volumetric images is not possible with high temporal and spatial resolution. A novel multislice acquisition scheme that is based on a two-dimensional navigator, instead of a commonly used pencil-beam navigator, was devised to acquire the data slices and the corresponding navigator simultaneously using a CAIPIRINHA parallel imaging method. The acquisition duration for four-dimensional dataset sampling is reduced compared to the existing approaches, while the image contrast and quality are improved as well.
Tracking respiratory organ motion is required in interventional procedures and during MR imaging of moving organs. An MR-based navigator is commonly used, however, it is usually associated with image artifacts, such as signal voids. Spectrally selective navigators can come in handy in cases where the imaging organ is surrounding with an adipose tissue, because it can provide an indirect measure of organ motion. A novel spectrally selective navigator based on a crossed-pair navigator has been developed. Experiments show the advantages of the application of this novel navigator for the volumetric imaging of the liver in vivo, where this navigator was used to gate the gradient-recalled echo sequence
Axon diameters and myelin content modulate microscopic fractional anisotropy at short diffusion times in fixed rat spinal cord
Mapping tissue microstructure accurately and noninvasively is one of the
frontiers of biomedical imaging. Diffusion Magnetic Resonance Imaging (MRI) is
at the forefront of such efforts, as it is capable of reporting on microscopic
structures orders of magnitude smaller than the voxel size by probing
restricted diffusion. Double Diffusion Encoding (DDE) and Double Oscillating
Diffusion Encoding (DODE) in particular, are highly promising for their ability
to report on microscopic fractional anisotropy ({\mu}FA), a measure of the pore
anisotropy in its own eigenframe, irrespective of orientation distribution.
However, the underlying correlates of {\mu}FA have insofar not been studied.
Here, we extract {\mu}FA from DDE and DODE measurements at ultrahigh magnetic
field of 16.4T in the aim to probe fixed rat spinal cord microstructure. We
further endeavor to correlate {\mu}FA with Myelin Water Fraction (MWF) derived
from multiexponential T2 relaxometry, as well as with literature-based
spatially varying axonal diameters. In addition, a simple new method is
presented for extracting unbiased {\mu}FA from three measurements at different
b-values. Our findings reveal strong anticorrelations between {\mu}FA (derived
from DODE) and axon diameter in the distinct spinal cord tracts; a moderate
correlation was also observed between {\mu}FA derived from DODE and MWF. These
findings suggest that axonal membranes strongly modulate {\mu}FA, which - owing
to its robustness towards orientation dispersion effects - reflects axon
diameter much better than its typical FA counterpart. The {\mu}FA exhibited
modulations when measured via oscillating or blocked gradients, suggesting
selective probing of different parallel path lengths and providing insight into
how those modulate {\mu}FA metrics. Our findings thus shed light into the
underlying microstructural correlates of {\mu}FA and are (...
Serial Correlations in Single-Subject fMRI with Sub-Second TR
When performing statistical analysis of single-subject fMRI data, serial
correlations need to be taken into account to allow for valid inference.
Otherwise, the variability in the parameter estimates might be under-estimated
resulting in increased false-positive rates. Serial correlations in fMRI data
are commonly characterized in terms of a first-order autoregressive (AR)
process and then removed via pre-whitening. The required noise model for the
pre-whitening depends on a number of parameters, particularly the repetition
time (TR). Here we investigate how the sub-second temporal resolution provided
by simultaneous multislice (SMS) imaging changes the noise structure in fMRI
time series. We fit a higher-order AR model and then estimate the optimal AR
model order for a sequence with a TR of less than 600 ms providing whole brain
coverage. We show that physiological noise modelling successfully reduces the
required AR model order, but remaining serial correlations necessitate an
advanced noise model. We conclude that commonly used noise models, such as the
AR(1) model, are inadequate for modelling serial correlations in fMRI using
sub-second TRs. Rather, physiological noise modelling in combination with
advanced pre-whitening schemes enable valid inference in single-subject
analysis using fast fMRI sequences
- …