14,826 research outputs found
New instruments and technologies for Cultural Heritage survey: full integration between point clouds and digital photogrammetry
In the last years the Geomatic Research Group of the Politecnico di Torino faced some new research topics about new instruments for point cloud generation (e.g. Time of Flight cameras) and strong integration between multi-image matching techniques and 3D Point Cloud information in order to solve the ambiguities of the already known matching algorithms. ToF cameras can be a good low cost alternative to LiDAR instruments for the generation of precise and accurate point clouds: up to now the application range is still limited but in a near future they will be able to satisfy the most part of the Cultural Heritage metric survey requirements. On the other hand multi-image matching techniques with a correct and deep integration of the point cloud information can give the correct solution for an "intelligent" survey of the geometric object break-lines, which are the correct starting point for a complete survey. These two research topics are strictly connected to a modern Cultural Heritage 3D survey approach. In this paper after a short analysis of the achieved results, an alternative possible scenario for the development of the metric survey approach inside the wider topic of Cultural Heritage Documentation is reporte
High-speed imaging in fluids
High-speed imaging is in popular demand for a broad range of experiments in fluids. It allows for a detailed visualization of the event under study by acquiring a series of image frames captured at high temporal and spatial resolution. This review covers high-speed imaging basics, by defining criteria for high-speed imaging experiments in fluids and to give rule-of-thumbs for a series of cases. It also considers stroboscopic imaging, triggering and illumination, and scaling issues. It provides guidelines for testing and calibration. Ultra high-speed imaging at frame rates exceeding 1 million frames per second is reviewed, and the combination of conventional experiments in fluids techniques with high-speed imaging techniques are discussed. The review is concluded with a high-speed imaging chart, which summarizes criteria for temporal scale and spatial scale and which facilitates the selection of a high-speed imaging system for the applicatio
Mitigation of H.264 and H.265 Video Compression for Reliable PRNU Estimation
The photo-response non-uniformity (PRNU) is a distinctive image sensor
characteristic, and an imaging device inadvertently introduces its sensor's
PRNU into all media it captures. Therefore, the PRNU can be regarded as a
camera fingerprint and used for source attribution. The imaging pipeline in a
camera, however, involves various processing steps that are detrimental to PRNU
estimation. In the context of photographic images, these challenges are
successfully addressed and the method for estimating a sensor's PRNU pattern is
well established. However, various additional challenges related to generation
of videos remain largely untackled. With this perspective, this work introduces
methods to mitigate disruptive effects of widely deployed H.264 and H.265 video
compression standards on PRNU estimation. Our approach involves an intervention
in the decoding process to eliminate a filtering procedure applied at the
decoder to reduce blockiness. It also utilizes decoding parameters to develop a
weighting scheme and adjust the contribution of video frames at the macroblock
level to PRNU estimation process. Results obtained on videos captured by 28
cameras show that our approach increases the PRNU matching metric up to more
than five times over the conventional estimation method tailored for photos
Non-Invasive Measurement of Frog Skin Reflectivity in High Spatial Resolution Using a Dual Hyperspectral Approach
Background:Most spectral data for the amphibian integument are limited to the visible spectrum of light and have been collected using point measurements with low spatial resolution. In the present study a dual camera setup consisting of two push broom hyperspectral imaging systems was employed, which produces reflectance images between 400 and 2500 nm with high spectral and spatial resolution and a high dynamic range.Methodology/Principal Findings:We briefly introduce the system and document the high efficiency of this technique analyzing exemplarily the spectral reflectivity of the integument of three arboreal anuran species (Litoria caerulea, Agalychnis callidryas and Hyla arborea), all of which appear green to the human eye. The imaging setup generates a high number of spectral bands within seconds and allows non-invasive characterization of spectral characteristics with relatively high working distance. Despite the comparatively uniform coloration, spectral reflectivity between 700 and 1100 nm differed markedly among the species. In contrast to H. arborea, L. caerulea and A. callidryas showed reflection in this range. For all three species, reflectivity above 1100 nm is primarily defined by water absorption. Furthermore, the high resolution allowed examining even small structures such as fingers and toes, which in A. callidryas showed an increased reflectivity in the near infrared part of the spectrum.Conclusion/Significance:Hyperspectral imaging was found to be a very useful alternative technique combining the spectral resolution of spectrometric measurements with a higher spatial resolution. In addition, we used Digital Infrared/Red-Edge Photography as new simple method to roughly determine the near infrared reflectivity of frog specimens in field, where hyperspectral imaging is typically difficult. © 2013 Pinto et al
- …