395 research outputs found

    Soft touchless sensors and touchless sensing for soft robots

    Get PDF
    Soft robots are characterized by their mechanical compliance, making them well-suited for various bio-inspired applications. However, the challenge of preserving their flexibility during deployment has necessitated using soft sensors which can enhance their mobility, energy efficiency, and spatial adaptability. Through emulating the structure, strategies, and working principles of human senses, soft robots can detect stimuli without direct contact with soft touchless sensors and tactile stimuli. This has resulted in noteworthy progress within the field of soft robotics. Nevertheless, soft, touchless sensors offer the advantage of non-invasive sensing and gripping without the drawbacks linked to physical contact. Consequently, the popularity of soft touchless sensors has grown in recent years, as they facilitate intuitive and safe interactions with humans, other robots, and the surrounding environment. This review explores the emerging confluence of touchless sensing and soft robotics, outlining a roadmap for deployable soft robots to achieve human-level dexterity

    Proceedings XXIII Congresso SIAMOC 2023

    Get PDF
    Il congresso annuale della Società Italiana di Analisi del Movimento in Clinica (SIAMOC), giunto quest’anno alla sua ventitreesima edizione, approda nuovamente a Roma. Il congresso SIAMOC, come ogni anno, è l’occasione per tutti i professionisti che operano nell’ambito dell’analisi del movimento di incontrarsi, presentare i risultati delle proprie ricerche e rimanere aggiornati sulle più recenti innovazioni riguardanti le procedure e le tecnologie per l’analisi del movimento nella pratica clinica. Il congresso SIAMOC 2023 di Roma si propone l’obiettivo di fornire ulteriore impulso ad una già eccellente attività di ricerca italiana nel settore dell’analisi del movimento e di conferirle ulteriore respiro ed impatto internazionale. Oltre ai qualificanti temi tradizionali che riguardano la ricerca di base e applicata in ambito clinico e sportivo, il congresso SIAMOC 2023 intende approfondire ulteriori tematiche di particolare interesse scientifico e di impatto sulla società. Tra questi temi anche quello dell’inserimento lavorativo di persone affette da disabilità anche grazie alla diffusione esponenziale in ambito clinico-occupazionale delle tecnologie robotiche collaborative e quello della protesica innovativa a supporto delle persone con amputazione. Verrà infine affrontato il tema dei nuovi algoritmi di intelligenza artificiale per l’ottimizzazione della classificazione in tempo reale dei pattern motori nei vari campi di applicazione

    Active Tactile Sensing for Texture Perception in Robotic Systems

    Get PDF
    This thesis presents a comprehensive study of tactile sensing, particularly on the prob- lem of active texture perception. It includes a brief introduction to tactile sensing technology and the neural basis for tactile perception. It follows the literature review of textural percep- tion with tactile sensing. I propose a decoding and perception pipeline to tackle fine-texture classification/identification problems via active touching. Experiments are conducted using a 7DOF robotic arm with a finger-shaped tactile sensor mounted on the end-effector to per- form sliding/rubbing movements on multiple fabrics. Low-dimensional frequency features are extracted from the raw signals to form a perceptive feature space, where tactile signals are mapped and segregated into fabric classes. Fabric classes can be parameterized and sim- plified in the feature space using elliptical equations. Results from experiments of varied control parameters are compared and visualized to show that different exploratory move- ments have an apparent impact on the perceived tactile information. It implies the possibil- ity of optimising the robotic movements to improve the textural classification/identification performance

    Designing a New Tactile Display Technology and its Disability Interactions

    Get PDF
    People with visual impairments have a strong desire for a refreshable tactile interface that can provide immediate access to full page of Braille and tactile graphics. Regrettably, existing devices come at a considerable expense and remain out of reach for many. The exorbitant costs associated with current tactile displays stem from their intricate design and the multitude of components needed for their construction. This underscores the pressing need for technological innovation that can enhance tactile displays, making them more accessible and available to individuals with visual impairments. This research thesis delves into the development of a novel tactile display technology known as Tacilia. This technology's necessity and prerequisites are informed by in-depth qualitative engagements with students who have visual impairments, alongside a systematic analysis of the prevailing architectures underpinning existing tactile display technologies. The evolution of Tacilia unfolds through iterative processes encompassing conceptualisation, prototyping, and evaluation. With Tacilia, three distinct products and interactive experiences are explored, empowering individuals to manually draw tactile graphics, generate digitally designed media through printing, and display these creations on a dynamic pin array display. This innovation underscores Tacilia's capability to streamline the creation of refreshable tactile displays, rendering them more fitting, usable, and economically viable for people with visual impairments

    Design, fabrication and stiffening of soft pneumatic robots

    Get PDF
    Although compliance allows the soft robot to be under-actuated and generalise its control, it also impacts the ability of the robot to exert forces on the environment. There is a trade-off between robots being compliant or precise and strong. Many mechanisms that change robots' stiffness on demand have been proposed, but none are perfect, usually compromising the device's compliance and restricting its motion capabilities. Keeping the above issues in mind, this thesis focuses on creating robust and reliable pneumatic actuators, that are designed to be easily manufactured with simple tools. They are optimised towards linear behaviour, which simplifies modelling and improve control strategies. The principle idea in relation to linearisation is a reinforcement strategy designed to amplify the desired, and limit the unwanted, deformation of the device. Such reinforcement can be achieved using fibres or 3D printed structures. I have shown that the linearity of the actuation is, among others, a function of the reinforcement density and shape, in that the response of dense fibre-reinforced actuators with a circular cross-section is significantly more linear than that of non-reinforced or non-circular actuators. I have explored moulding manufacturing techniques and a mixture of 3D printing and moulding. Many aspects of these techniques have been optimised for reliability, repeatability, and process simplification. I have proposed and implemented a novel moulding technique that uses disposable moulds and can easily be used by an inexperienced operator. I also tried to address the compliance-stiffness trade-off issue. As a result, I have proposed an intelligent structure that behaves differently depending on the conditions. Thanks to its properties, such a structure could be used in applications that require flexibility, but also the ability to resist external disturbances when necessary. Due to its nature, individual cells of the proposed system could be used to implement physical logic elements, resulting in embodied intelligent behaviours. As a proof-of-concept, I have demonstrated use of my actuators in several applications including prosthetic hands, octopus, and fish robots. Each of those devices benefits from a slightly different actuation system but each is based on the same core idea - fibre reinforced actuators. I have shown that the proposed design and manufacturing techniques have several advantages over the methods used so far. The manufacturing methods I developed are more reliable, repeatable, and require less manual work than the various other methods described in the literature. I have also shown that the proposed actuators can be successfully used in real-life applications. Finally, one of the most important outcomes of my research is a contribution to an orthotic device based on soft pneumatic actuators. The device has been successfully deployed, and, at the time of submission of this thesis, has been used for several months, with good results reported, by a patient

    a Soft Hand Exoskeleton With a Novel Tendon Layout to Improve Stable Wearing in Grasping Assistance

    Get PDF
    : We present a novel soft exoskeleton providing active support for hand closing and opening. The main novelty is a different tendon routing, folded laterally on both sides of the hand, and adding clenching forces when the exoskeleton is activated. It improves the stability of the glove, diminishing slippage and detachment of tendons from the hand palm toward the grasping workspace. The clenching effect is released when the hand is relaxed, thus enhancing the user's comfort. The alternative routing allowed embedding a single actuator on the hand dorsum, resulting more compact with no remote cable transmission. Enhanced adaptation to the hand is introduced by the modular design of the soft polymer open rings. FEM simulations were performed to understand the interaction between soft modules and fingers. Different experiments assessed the desired effect of the proposed routing in terms of stability and deformation of the glove, evaluated the inter-finger compliance for non-cylindrical grasping, and characterized the output grasping force. Experiments with subjects explored the grasping performance of the soft exoskeleton with different hand sizes. A preliminary evaluation with Spinal Cord Injury patients was useful to highlight the strengths and limitations of the device when applied to the target scenario

    The Impact of Real-World Vibration Gait Retraining on Gait Biomechanics in People with Chronic Ankle Instability

    Get PDF
    Background: Following an initial ankle sprain, 40% of individuals develop chronic ankle instability (CAI) characterized by incomplete resolution of impairments and functional limitations. CAI stems from interactions between multiple impairments including altered movement patterns. Real-world vibration feedback gait retraining (RW-VF) decreases lateral center of pressures (COP) and excessive inversion in people with CAI which are thought to lead to increased ankle sprain risk and early joint degeneration. However, it remains unknown how cumulative training impacts immediate and long-term gait biomechanics. Purpose: To determine how two-weeks of RW-VF impacts COP location and explore influences of feedback sensor location and modifiable/ non-modifiable factors on capacity for COP change in people with CAI. Methods: In two separate studies, participants walked with a custom vibration feedback tool. In the first study, measures of modifiable and non-modifiable factors were obtained (Foot posture index (FPI), tibial varum, dorsiflexion range of motion (ROM), calcaneal eversion ROM, and postural control) before walking on a treadmill with feedback. Participants completed two sessions with the feedback sensor under either the 5th metatarsal head (5MH) or the lateral heel. In the second study, baseline biomechanics were measured while walking on a treadmill with no feedback followed by 6 real-world training session sessions with feedback. Posttest biomechanics were collected after a single and 6 RW-VF sessions. Retention was measured after 1-week of no intervention.Results: Sensor location did not impact COP location during walking with either sensor location, but the heel location generated a mid-forefoot initial contact and a shortened step length. A pronated foot, decreased ROM, and worse postural control were associated with decreased capacity to change COP. Finally, following a single training the COP changed during late stance and after multiple trainings the COP changed during early stance with moderate retention. However, at baseline, the CAI COP was not statistically different than controls during key gait events. Conclusion: Cumulatively, these results suggest that RW-VF is a feasible intervention to make lasting gait changes in people with CAI, however, target variables should be individualized, and gait retraining should be combined with other interventions which may improve the capacity to change.Doctor of Philosoph

    Novel Bidirectional Body - Machine Interface to Control Upper Limb Prosthesis

    Get PDF
    Objective. The journey of a bionic prosthetic user is characterized by the opportunities and limitations involved in adopting a device (the prosthesis) that should enable activities of daily living (ADL). Within this context, experiencing a bionic hand as a functional (and, possibly, embodied) limb constitutes the premise for mitigating the risk of its abandonment through the continuous use of the device. To achieve such a result, different aspects must be considered for making the artificial limb an effective support for carrying out ADLs. Among them, intuitive and robust control is fundamental to improving amputees’ quality of life using upper limb prostheses. Still, as artificial proprioception is essential to perceive the prosthesis movement without constant visual attention, a good control framework may not be enough to restore practical functionality to the limb. To overcome this, bidirectional communication between the user and the prosthesis has been recently introduced and is a requirement of utmost importance in developing prosthetic hands. Indeed, closing the control loop between the user and a prosthesis by providing artificial sensory feedback is a fundamental step towards the complete restoration of the lost sensory-motor functions. Within my PhD work, I proposed the development of a more controllable and sensitive human-like hand prosthesis, i.e., the Hannes prosthetic hand, to improve its usability and effectiveness. Approach. To achieve the objectives of this thesis work, I developed a modular and scalable software and firmware architecture to control the Hannes prosthetic multi-Degree of Freedom (DoF) system and to fit all users’ needs (hand aperture, wrist rotation, and wrist flexion in different combinations). On top of this, I developed several Pattern Recognition (PR) algorithms to translate electromyographic (EMG) activity into complex movements. However, stability and repeatability were still unmet requirements in multi-DoF upper limb systems; hence, I started by investigating different strategies to produce a more robust control. To do this, EMG signals were collected from trans-radial amputees using an array of up to six sensors placed over the skin. Secondly, I developed a vibrotactile system to implement haptic feedback to restore proprioception and create a bidirectional connection between the user and the prosthesis. Similarly, I implemented an object stiffness detection to restore tactile sensation able to connect the user with the external word. This closed-loop control between EMG and vibration feedback is essential to implementing a Bidirectional Body - Machine Interface to impact amputees’ daily life strongly. For each of these three activities: (i) implementation of robust pattern recognition control algorithms, (ii) restoration of proprioception, and (iii) restoration of the feeling of the grasped object's stiffness, I performed a study where data from healthy subjects and amputees was collected, in order to demonstrate the efficacy and usability of my implementations. In each study, I evaluated both the algorithms and the subjects’ ability to use the prosthesis by means of the F1Score parameter (offline) and the Target Achievement Control test-TAC (online). With this test, I analyzed the error rate, path efficiency, and time efficiency in completing different tasks. Main results. Among the several tested methods for Pattern Recognition, the Non-Linear Logistic Regression (NLR) resulted to be the best algorithm in terms of F1Score (99%, robustness), whereas the minimum number of electrodes needed for its functioning was determined to be 4 in the conducted offline analyses. Further, I demonstrated that its low computational burden allowed its implementation and integration on a microcontroller running at a sampling frequency of 300Hz (efficiency). Finally, the online implementation allowed the subject to simultaneously control the Hannes prosthesis DoFs, in a bioinspired and human-like way. In addition, I performed further tests with the same NLR-based control by endowing it with closed-loop proprioceptive feedback. In this scenario, the results achieved during the TAC test obtained an error rate of 15% and a path efficiency of 60% in experiments where no sources of information were available (no visual and no audio feedback). Such results demonstrated an improvement in the controllability of the system with an impact on user experience. Significance. The obtained results confirmed the hypothesis of improving robustness and efficiency of a prosthetic control thanks to of the implemented closed-loop approach. The bidirectional communication between the user and the prosthesis is capable to restore the loss of sensory functionality, with promising implications on direct translation in the clinical practice

    A Mechanical Hand-Tracking System with Tactile Feedback Designed for Telemanipulation

    Get PDF
    : In this paper, we present a mechanical hand-tracking system with tactile feedback designed for fine manipulation in teleoperation scenarios. Alternative tracking methods based on artificial vision and data gloves have become an asset for virtual reality interaction. Yet, occlusions, lack of precision, and the absence of effective haptic feedback beyond vibrotactile still appear as a limit for teleoperation applications. In this work, we propose a methodology to design a linkage mechanism for hand pose tracking purposes, preserving complete finger mobility. Presentation of the method is followed by design and implementation of a working prototype, and by evaluation of the tracking accuracy using optical markers. Moreover, a teleoperation experiment involving a dexterous robotic arm and hand was proposed to ten participants. It investigated the effectiveness and repeatability of the hand tracking with combined haptic feedback during a proposed pick and place manipulation tasks
    • …
    corecore