3,418 research outputs found

    Review of Development Stages in the Conceptual Design of an Electro Hydrostatic Actuator for Robotics

    Get PDF
    The design of modern robotic devices faces numerous requirements and limitations which are related to optimization and robustness. Consequently, these stringent requirements have caused improvements in many engineering areas and lead to development of new optimization methods which better handle new complex products designed for application in industrial robots. One of the newly developed methods used in industrial robotics is the concept of a self-contained power device, an Electro-Hydrostatic Actuator (EHA). EHA devices were designed with a central idea, to avoid the possible drawbacks which were present in other types of actuators that are currently used in robotic systems. This paper is a review of the development phases of an EHA device for robotic applications. An overview of the advantages and disadvantages related to current EHA designs are presented, and finally possible ideas for future developments are suggested

    Towards a cyber physical system for personalised and automatic OSA treatment

    Get PDF
    Obstructive sleep apnea (OSA) is a breathing disorder that takes place in the course of the sleep and is produced by a complete or a partial obstruction of the upper airway that manifests itself as frequent breathing stops and starts during the sleep. The real-time evaluation of whether or not a patient is undergoing OSA episode is a very important task in medicine in many scenarios, as for example for making instantaneous pressure adjustments that should take place when Automatic Positive Airway Pressure (APAP) devices are used during the treatment of OSA. In this paper the design of a possible Cyber Physical System (CPS) suited to real-time monitoring of OSA is described, and its software architecture and possible hardware sensing components are detailed. It should be emphasized here that this paper does not deal with a full CPS, rather with a software part of it under a set of assumptions on the environment. The paper also reports some preliminary experiments about the cognitive and learning capabilities of the designed CPS involving its use on a publicly available sleep apnea database

    Actuators for a space manipulator

    Get PDF
    The robotic manipulator can be decomposed into distinct subsytems. One particular area of interest of mechanical subsystems is electromechanical actuators (or drives). A drive is defined as a motor with an appropriate transmission. An overview is given of existing, as well as state-of-the-art drive systems. The scope is limited to space applications. A design philosophy and adequate requirements are the initial steps in designing a space-qualified actuator. The focus is on the d-c motor in conjunction with several types of transmissions (harmonic, tendon, traction, and gear systems). The various transmissions will be evaluated and key performance parameters will be addressed in detail. Included in the assessment is a shuttle RMS joint and a MSFC drive of the Prototype Manipulator Arm. Compound joints are also investigated. Space imposes a set of requirements for designing a high-performance drive assembly. Its inaccessibility and cryogenic conditions warrant special considerations. Some guidelines concerning these conditions are present. The goal is to gain a better understanding in designing a space actuator

    Design and implementation of fuzzy based control system for natural gas pipes system based on LabVIEW

    Get PDF
    The quality of Natural Gas Piping Systems (NGPS) must be ensured against any manufacturing defects. For this purpose, we develop a special testing machine (STM) constructed at the lab to test (NGPS). The proposed (STM) function is based on testing the weak points at the pipe connections e.g. pipe bends, and intermediate connections. For more than 1500 pieces of (NGPS), crack propagation simultaneously followed up and monitored on the output screen at the critical positions of the pipelines connections. The control system utilizes the LabVIEW tools for various signals acquisition and monitoring also for designing the control system strategy

    Agricultural robotics: part of the new deal?

    Get PDF
    Throughout the fifth edition of the International Forum of Agricultural Robots (FIRA) in December 2020, more than 1,500 farmers, manufacturers, advanced technology suppliers, innovators, investors, journalists and experts from 71 countries around the world gathered to ask questions, share stories and exchange ideas about agricultural robots. This book is a journey into the state of the art of this industry in 2020, and includes 27 agricultural robot information sheets. It is designed to provide a nuanced look at the industry’s most pressing topics, from the overarching impact of the global food crisis to the everyday influence of semi-autonomous tractors on a family-owned farm in France. The book achieves this goal by taking a deep dive into the perspectives shared by FIRA 2020 presenters and panelists

    Proposal of a health care network based on big data analytics for PDs

    Get PDF
    Health care networks for Parkinson's disease (PD) already exist and have been already proposed in the literature, but most of them are not able to analyse the vast volume of data generated from medical examinations and collected and organised in a pre-defined manner. In this work, the authors propose a novel health care network based on big data analytics for PD. The main goal of the proposed architecture is to support clinicians in the objective assessment of the typical PD motor issues and alterations. The proposed health care network has the ability to retrieve a vast volume of acquired heterogeneous data from a Data warehouse and train an ensemble SVM to classify and rate the motor severity of a PD patient. Once the network is trained, it will be able to analyse the data collected during motor examinations of a PD patient and generate a diagnostic report on the basis of the previously acquired knowledge. Such a diagnostic report represents a tool both to monitor the follow up of the disease for each patient and give robust advice about the severity of the disease to clinicians

    Investigations into the design of a wheelchair-mounted rehabilitation robotic manipulator

    Get PDF
    This research describes the steps towards the development of a low-cost wheelchair-mounted manipulator for use by the physically disabled and elderly. A detailed review of world rehabilitation robotics research has been conducted, covering fifty-six projects. This identified the main areas of research, their scope and results. From this review, a critical investigation of past and present wheelchair-mounted robotic arm projects was undertaken. This led to the formulation of the key design parameters in a final design specification. The results of a questionnaire survey of fifty electric wheelchair users is presented, which has for the first time established the needs and abilities of this disability group. An analysis of muscle type actuators, which mimic human muscle, is presented and their application to robotics, orthotics and prosthetics is given. A new type of rotary pneumatic muscle actuator, the flexator, is introduced and through extensive testing its performance characteristics elucidated. A review of direct-drive rotary pneumatic, hydraulic and electrical actuators has highlighted their relative performance characteristics and has rated their efficiency in terms of their peak torque to motor mass ratio, Tp/MM. From this, the flexator actuator has been shown to have a higher Tp/MM ratio than most conventional actuators. A novel kinematic arrangement is presented which combines the best features of the SCARA and vertically articulated industrial robot geometries, to form the 'Scariculated' arm design. The most appropriate actuator for each joint of this hybrid manipulator was selected, based on the criteria of high Tp/MM ratio, low cost, safety and compatibility. The final design incorporates conventional pneumatic linear double-acting cylinders, a vane type rotary actuator, two dual flexator actuators, and stepping motors for the fme control of the wrist/end effector. An ACSL simulation program has been developed which uses mass flow rate equations, based on one-dimensional compressible flow theory and suppressed critical pressure ratios, to simulate the dual flexator actuator. Theoretical and empirical data is compared and shows a high degree of correlation between results. Finally, the design and development work on two prototypes is discussed. The latest prototype consists of a five-axis manipulator whose pneumatic joints are driven by pulse width modulated solenoid valves. An 8051 microprocessor with proportional error feedback modilles the mark to space ratio of the PWM signal in proportion to the angular error of the joints. This enables control over individual joint speeds, reprogrammable memory locations and position monitoring of each joint. The integration of rehabilitation robotic manipulators into the daily lives of the physically disabled and elderly will significantly influence the role of personal rehabilitation in the next century

    Cyber-Agricultural Systems for Crop Breeding and Sustainable Production

    Get PDF
    The Cyber-Agricultural System (CAS) Represents an overarching Framework of Agriculture that Leverages Recent Advances in Ubiquitous Sensing, Artificial Intelligence, Smart Actuators, and Scalable Cyberinfrastructure (CI) in Both Breeding and Production Agriculture. We Discuss the Recent Progress and Perspective of the Three Fundamental Components of CAS – Sensing, Modeling, and Actuation – and the Emerging Concept of Agricultural Digital Twins (DTs). We Also Discuss How Scalable CI is Becoming a Key Enabler of Smart Agriculture. in This Review We Shed Light on the Significance of CAS in Revolutionizing Crop Breeding and Production by Enhancing Efficiency, Productivity, Sustainability, and Resilience to Changing Climate. Finally, We Identify Underexplored and Promising Future Directions for CAS Research and Development

    A review on design of upper limb exoskeletons

    Get PDF
    • …
    corecore