104 research outputs found

    Wireless intraoral tongue control of an assistive robotic arm for individuals with tetraplegia

    Get PDF
    Abstract Background For an individual with tetraplegia assistive robotic arms provide a potentially invaluable opportunity for rehabilitation. However, there is a lack of available control methods to allow these individuals to fully control the assistive arms. Methods Here we show that it is possible for an individual with tetraplegia to use the tongue to fully control all 14 movements of an assistive robotic arm in a three dimensional space using a wireless intraoral control system, thus allowing for numerous activities of daily living. We developed a tongue-based robotic control method incorporating a multi-sensor inductive tongue interface. One abled-bodied individual and one individual with tetraplegia performed a proof of concept study by controlling the robot with their tongue using direct actuator control and endpoint control, respectively. Results After 30 min of training, the able-bodied experimental participant tongue controlled the assistive robot to pick up a roll of tape in 80% of the attempts. Further, the individual with tetraplegia succeeded in fully tongue controlling the assistive robot to reach for and touch a roll of tape in 100% of the attempts and to pick up the roll in 50% of the attempts. Furthermore, she controlled the robot to grasp a bottle of water and pour its contents into a cup; her first functional action in 19 years. Conclusion To our knowledge, this is the first time that an individual with tetraplegia has been able to fully control an assistive robotic arm using a wireless intraoral tongue interface. The tongue interface used to control the robot is currently available for control of computers and of powered wheelchairs, and the robot employed in this study is also commercially available. Therefore, the presented results may translate into available solutions within reasonable time

    Principles of human movement augmentation and the challenges in making it a reality

    Get PDF
    Augmenting the body with artificial limbs controlled concurrently to one's natural limbs has long appeared in science fiction, but recent technological and neuroscientific advances have begun to make this possible. By allowing individuals to achieve otherwise impossible actions, movement augmentation could revolutionize medical and industrial applications and profoundly change the way humans interact with the environment. Here, we construct a movement augmentation taxonomy through what is augmented and how it is achieved. With this framework, we analyze augmentation that extends the number of degrees-of-freedom, discuss critical features of effective augmentation such as physiological control signals, sensory feedback and learning as well as application scenarios, and propose a vision for the field

    Tongue Control of Upper-Limb Exoskeletons For Individuals With Tetraplegia

    Get PDF

    Advanced Bionic Attachment Equipment Inspired by the Attachment Performance of Aquatic Organisms: A Review

    Get PDF
    In nature, aquatic organisms have evolved various attachment systems, and their attachment ability has become a specific and mysterious survival skill for them. Therefore, it is significant to study and use their unique attachment surfaces and outstanding attachment characteristics for reference and develop new attachment equipment with excellent performance. Based on this, in this review, the unique non-smooth surface morphologies of their suction cups are classified and the key roles of these special surface morphologies in the attachment process are introduced in detail. The recent research on the attachment capacity of aquatic suction cups and other related attachment studies are described. Emphatically, the research progress of advanced bionic attachment equipment and technology in recent years, including attachment robots, flexible grasping manipulators, suction cup accessories, micro-suction cup patches, etc., is summarized. Finally, the existing problems and challenges in the field of biomimetic attachment are analyzed, and the focus and direction of biomimetic attachment research in the future are pointed out

    Use and evaluation of assistive technologies for upper limb function in tetraplegia

    Get PDF
    Context More than half of all spinal cord injuries (SCI) occur at the cervical level leading to loss of upper limb function, restricted activity and reduced independence. Several technologies have been developed to assist with upper limb functions in the SCI population. Objective There is no clear clinical consensus on the effectiveness of the current assistive technologies for the cervical SCI population, hence this study reviews the literature in the years between 1999 and 2019. Methods A systematic review was performed on the state-of-the-art assistive technology that supports and improves the function of impaired upper limbs in cervical SCI populations. Combinations of terms, covering assistive technology, SCI, and upper limb, were used in the search, which resulted in a total of 1770 articles. Data extractions were performed on the selected studies which involved summarizing details on the assistive technologies, characteristics of study participants, outcome measures, and improved upper limb functions when using the device. Results A total of 24 articles were found and grouped into five categories, including neuroprostheses (invasive and non-invasive), orthotic devices, hybrid systems, robots, and arm supports. Only a few selected studies comprehensively reported characteristics of the participants. There was a wide range of outcome measures and all studies reported improvements in upper limb function with the devices. Conclusions This study highlighted that assistive technologies can improve functions of the upper limbs in SCI patients. It was challenging to draw generalizable conclusions because of factors, such as heterogeneity of recruited participants, a wide range of outcome measures, and the different technologies employed

    Retainer-Free Optopalatographic Device Design and Evaluation as a Feedback Tool in Post-Stroke Speech and Swallowing Therapy

    Get PDF
    Stroke is one of the leading causes of long-term motor disability, including oro-facial impairments which affect speech and swallowing. Over the last decades, rehabilitation programs have evolved from utilizing mainly compensatory measures to focusing on recovering lost function. In the continuing effort to improve recovery, the concept of biofeedback has increasingly been leveraged to enhance self-efficacy, motivation and engagement during training. Although both speech and swallowing disturbances resulting from oro-facial impairments are frequent sequelae of stroke, efforts to develop sensing technologies that provide comprehensive and quantitative feedback on articulator kinematics and kinetics, especially those of the tongue, and specifically during post-stroke speech and swallowing therapy have been sparse. To that end, such a sensing device needs to accurately capture intraoral tongue motion and contact with the hard palate, which can then be translated into an appropriate form of feedback, without affecting tongue motion itself and while still being light-weight and portable. This dissertation proposes the use of an intraoral sensing principle known as optopalatography to provide such feedback while also exploring the design of optopalatographic devices itself for use in dysphagia and dysarthria therapy. Additionally, it presents an alternative means of holding the device in place inside the oral cavity with a newly developed palatal adhesive instead of relying on dental retainers, which previously limited device usage to a single person. The evaluation was performed on the task of automatically classifying different functional tongue exercises from one another with application in dysphagia therapy, whereas a phoneme recognition task was conducted with application in dysarthria therapy. Results on the palatal adhesive suggest that it is indeed a valid alternative to dental retainers when device residence time inside the oral cavity is limited to several tens of minutes per session, which is the case for dysphagia and dysarthria therapy. Functional tongue exercises were classified with approximately 61 % accuracy across subjects, whereas for the phoneme recognition task, tense vowels had the highest recognition rate, followed by lax vowels and consonants. In summary, retainer-free optopalatography has the potential to become a viable method for providing real-time feedback on tongue movements inside the oral cavity, but still requires further improvements as outlined in the remarks on future development.:1 Introduction 1.1 Motivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Problem statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.3 Goals and contributions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.4 Scope and limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Basics of post-stroke speech and swallowing therapy 2.1 Dysarthria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 Dysphagia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Treatment rationale and potential of biofeedback . . . . . . . . . . . . . . . . . 13 2.4 Summary and conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3 Tongue motion sensing 3.1 Contact-based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.1 Electropalatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.2 Manometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.1.3 Capacitive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.2 Non-contact based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.1 Electromagnetic articulography . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.2 Permanent magnetic articulography . . . . . . . . . . . . . . . . . . . . 24 3.2.3 Optopalatography (related work) . . . . . . . . . . . . . . . . . . . . . . 25 3.3 Electro-optical stomatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.4 Extraoral sensing techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.5 Summary, comparison and conclusion . . . . . . . . . . . . . . . . . . . . . . . 29 4 Fundamentals of optopalatography 4.1 Important radiometric quantities . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.1 Solid angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.2 Radiant flux and radiant intensity . . . . . . . . . . . . . . . . . . . . . 33 4.1.3 Irradiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.1.4 Radiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.2 Sensing principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 4.2.1 Analytical models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.2.2 Monte Carlo ray tracing methods . . . . . . . . . . . . . . . . . . . . . . 37 4.2.3 Data-driven models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 4.2.4 Model comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 4.3 A priori device design consideration . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.1 Optoelectronic components . . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.2 Additional electrical components and requirements . . . . . . . . . . . . 43 4.3.3 Intraoral sensor layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5 Intraoral device anchorage 5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 5.1.1 Mucoadhesion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5.1.2 Considerations for the palatal adhesive . . . . . . . . . . . . . . . . . . . 48 5.2 Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.1 Polymer selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.2 Fabrication method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 5.2.3 Formulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.4 PEO tablets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.5 Connection to the intraoral sensor’s encapsulation . . . . . . . . . . . . 50 5.2.6 Formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 5.3 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.1 Initial formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.2 Final OPG adhesive formulation . . . . . . . . . . . . . . . . . . . . . . 56 5.4 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 6 Initial device design with application in dysphagia therapy 6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 6.2 Optode and optical sensor selection . . . . . . . . . . . . . . . . . . . . . . . . . 60 6.2.1 Optode and optical sensor evaluation procedure . . . . . . . . . . . . . . 61 6.2.2 Selected optical sensor characterization . . . . . . . . . . . . . . . . . . 62 6.2.3 Mapping from counts to millimeter . . . . . . . . . . . . . . . . . . . . . 62 6.2.4 Results and discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 6.3 Device design and hardware implementation . . . . . . . . . . . . . . . . . . . . 64 6.3.1 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 6.3.2 Optode placement and circuit board dimensions . . . . . . . . . . . . . 64 6.3.3 Firmware description and measurement cycle . . . . . . . . . . . . . . . 66 6.3.4 Encapsulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 6.3.5 Fully assembled OPG device . . . . . . . . . . . . . . . . . . . . . . . . 67 6.4 Evaluation on the gesture recognition task . . . . . . . . . . . . . . . . . . . . . 69 6.4.1 Exercise selection, setup and recording . . . . . . . . . . . . . . . . . . . 69 6.4.2 Data corpus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.3 Sequence pre-processing . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.4 Choice of classifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 6.4.5 Training and evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 6.4.6 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 6.5 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 7 Improved device design with application in dysarthria therapy 7.1 Device design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 7.1.1 Design considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 7.1.2 General system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.3 Intraoral sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.4 Receiver and controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 7.1.5 Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 7.2 Hardware implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 7.2.1 Optode placement and circuit board layout . . . . . . . . . . . . . . . . 87 7.2.2 Encapsulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 7.3 Device characterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 7.3.1 Photodiode transient response . . . . . . . . . . . . . . . . . . . . . . . 91 7.3.2 Current source and rise time . . . . . . . . . . . . . . . . . . . . . . . . 91 7.3.3 Multiplexer switching speed . . . . . . . . . . . . . . . . . . . . . . . . . 92 7.3.4 Measurement cycle and firmware implementation . . . . . . . . . . . . . 93 7.3.5 In vitro measurement accuracy . . . . . . . . . . . . . . . . . . . . . . . 95 7.3.6 Optode measurement stability . . . . . . . . . . . . . . . . . . . . . . . 96 7.4 Evaluation on the phoneme recognition task . . . . . . . . . . . . . . . . . . . . 98 7.4.1 Corpus selection and recording setup . . . . . . . . . . . . . . . . . . . . 98 7.4.2 Annotation and sensor data post-processing . . . . . . . . . . . . . . . . 98 7.4.3 Mapping from counts to millimeter . . . . . . . . . . . . . . . . . . . . . 99 7.4.4 Classifier and feature selection . . . . . . . . . . . . . . . . . . . . . . . 100 7.4.5 Evaluation paradigms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 7.5 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 7.5.1 Tongue distance curve prediction . . . . . . . . . . . . . . . . . . . . . . 105 7.5.2 Tongue contact patterns and contours . . . . . . . . . . . . . . . . . . . 105 7.5.3 Phoneme recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 7.6 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 8 Conclusion and future work 115 9 Appendix 9.1 Analytical light transport models . . . . . . . . . . . . . . . . . . . . . . . . . . 119 9.2 Meshed Monte Carlo method . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 9.3 Laser safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 9.4 Current source modulation voltage . . . . . . . . . . . . . . . . . . . . . . . . . 123 9.5 Transimpedance amplifier’s frequency responses . . . . . . . . . . . . . . . . . . 123 9.6 Initial OPG device’s PCB layout and circuit diagrams . . . . . . . . . . . . . . 127 9.7 Improved OPG device’s PCB layout and circuit diagrams . . . . . . . . . . . . 129 9.8 Test station layout drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Bibliography 152Der Schlaganfall ist eine der häufigsten Ursachen für motorische Langzeitbehinderungen, einschließlich solcher im Mund- und Gesichtsbereich, deren Folgen u.a. Sprech- und Schluckprobleme beinhalten, welche sich in den beiden Symptomen Dysarthrie und Dysphagie äußern. In den letzten Jahrzehnten haben sich Rehabilitationsprogramme für die Behandlung von motorisch ausgeprägten Schlaganfallsymptomatiken substantiell weiterentwickelt. So liegt nicht mehr die reine Kompensation von verlorengegangener motorischer Funktionalität im Vordergrund, sondern deren aktive Wiederherstellung. Dabei hat u.a. die Verwendung von sogenanntem Biofeedback vermehrt Einzug in die Therapie erhalten, um Motivation, Engagement und Selbstwahrnehmung von ansonsten unbewussten Bewegungsabläufen seitens der Patienten zu fördern. Obwohl jedoch Sprech- und Schluckstörungen eine der häufigsten Folgen eines Schlaganfalls darstellen, wird diese Tatsache nicht von der aktuellen Entwicklung neuer Geräte und Messmethoden für quantitatives und umfassendes Biofeedback reflektiert, insbesondere nicht für die explizite Erfassung intraoraler Zungenkinematik und -kinetik und für den Anwendungsfall in der Schlaganfalltherapie. Ein möglicher Grund dafür liegt in den sehr strikten Anforderungen an ein solche Messmethode: Sie muss neben Portabilität idealerweise sowohl den Kontakt zwischen der Zunge und dem Gaumen, als auch die dreidimensionale Bewegung der Zunge in der Mundhöhle erfassen, ohne dabei die Artikulation selbst zu beeinflussen. Um diesen Anforderungen gerecht zu werden, wird in dieser Dissertation das Messprinzip der Optopalatographie untersucht, mit dem Schwerpunkt auf der Anwendung in der Dysarthrie- und Dysphagietherapie. Dies beinhaltet auch die Entwicklung eines entsprechenden Gerätes sowie dessen Befestigungsmethode in der Mundhöhle über ein dediziertes Mundschleimhautadhäsiv. Letzteres umgeht das bisherige Problem der notwendigen Anpassung eines solchen intraoralen Gerätes an einen einzelnen Nutzer. Für die Anwendung in der Dysphagietherapie erfolgte die Evaluation anhand einer automatischen Erkennung von Mobilisationsübungen der Zunge, welche routinemäßig in der funktionalen Dysphagietherapie durchgeführt werden. Für die Anwendung in der Dysarthrietherapie wurde eine Lauterkennung durchgeführt. Die Resultate bezüglich der Verwendung des Mundschleimhautadhäsives suggerieren, dass dieses tatsächlich eine valide Alternative zu den bisher verwendeten Techniken zur Befestigung intraoraler Geräte in der Mundhöhle darstellt. Zungenmobilisationsübungen wurden über Probanden hinweg mit einer Rate von 61 % erkannt, wogegen in der Lauterkennung Langvokale die höchste Erkennungsrate erzielten, gefolgt von Kurzvokalen und Konsonanten. Zusammenfassend lässt sich konstatieren, dass das Prinzip der Optopalatographie eine ernstzunehmende Option für die intraorale Erfassung von Zungenbewegungen darstellt, wobei weitere Entwicklungsschritte notwendig sind, welche im Ausblick zusammengefasst sind.:1 Introduction 1.1 Motivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Problem statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.3 Goals and contributions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.4 Scope and limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Basics of post-stroke speech and swallowing therapy 2.1 Dysarthria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 Dysphagia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Treatment rationale and potential of biofeedback . . . . . . . . . . . . . . . . . 13 2.4 Summary and conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3 Tongue motion sensing 3.1 Contact-based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.1 Electropalatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.2 Manometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.1.3 Capacitive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.2 Non-contact based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.1 Electromagnetic articulography . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.2 Permanent magnetic articulography . . . . . . . . . . . . . . . . . . . . 24 3.2.3 Optopalatography (related work) . . . . . . . . . . . . . . . . . . . . . . 25 3.3 Electro-optical stomatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.4 Extraoral sensing techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.5 Summary, comparison and conclusion . . . . . . . . . . . . . . . . . . . . . . . 29 4 Fundamentals of optopalatography 4.1 Important radiometric quantities . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.1 Solid angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.2 Radiant flux and radiant intensity . . . . . . . . . . . . . . . . . . . . . 33 4.1.3 Irradiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.1.4 Radiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.2 Sensing principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 4.2.1 Analytical models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.2.2 Monte Carlo ray tracing methods . . . . . . . . . . . . . . . . . . . . . . 37 4.2.3 Data-driven models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 4.2.4 Model comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 4.3 A priori device design consideration . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.1 Optoelectronic components . . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.2 Additional electrical components and requirements . . . . . . . . . . . . 43 4.3.3 Intraoral sensor layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5 Intraoral device anchorage 5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 5.1.1 Mucoadhesion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5.1.2 Considerations for the palatal adhesive . . . . . . . . . . . . . . . . . . . 48 5.2 Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.1 Polymer selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.2 Fabrication method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 5.2.3 Formulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.4 PEO tablets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.5 Connection to the intraoral sensor’s encapsulation . . . . . . . . . . . . 50 5.2.6 Formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 5.3 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.1 Initial formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.2 Final OPG adhesive formulation . . . . . . . . . . . . . . . . . . . . . . 56 5.4 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 6 Initial device design with application in dysphagia therapy 6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 6.2 Optode and optical sensor selection . . . . . . . . . . . . . . . . . . . . . . . . . 60 6.2.1 Optode and optical sensor evaluation procedure . . . . . . . . . . . . . . 61 6.2.2 Selected optical sensor characterization . . . . . . . . . . . . . . . . . . 62 6.2.3 Mapping from counts to millimeter . . . . . . . . . . . . . . . . . . . . . 62 6.2.4 Results and discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 6.3 Device design and hardware implementation . . . . . . . . . . . . . . . . . . . . 64 6.3.1 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 6.3.2 Optode placement and circuit board dimensions . . . . . . . . . . . . . 64 6.3.3 Firmware description and measurement cycle . . . . . . . . . . . . . . . 66 6.3.4 Encapsulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 6.3.5 Fully assembled OPG device . . . . . . . . . . . . . . . . . . . . . . . . 67 6.4 Evaluation on the gesture recognition task . . . . . . . . . . . . . . . . . . . . . 69 6.4.1 Exercise selection, setup and recording . . . . . . . . . . . . . . . . . . . 69 6.4.2 Data corpus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.3 Sequence pre-processing . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.4 Choice of classifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 6.4.5 Training and evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 6.4.6 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 6.5 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 7 Improved device design with application in dysarthria therapy 7.1 Device design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 7.1.1 Design considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 7.1.2 General system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.3 Intraoral sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.4 Receiver and controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 7.1.5 Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 7.2 Hardware implementation . . . . . . . . . . . . . . . . . . . . .
    • …
    corecore