2,984 research outputs found

    Computer- and robot-assisted Medical Intervention

    Full text link
    Medical robotics includes assistive devices used by the physician in order to make his/her diagnostic or therapeutic practices easier and more efficient. This chapter focuses on such systems. It introduces the general field of Computer-Assisted Medical Interventions, its aims, its different components and describes the place of robots in that context. The evolutions in terms of general design and control paradigms in the development of medical robots are presented and issues specific to that application domain are discussed. A view of existing systems, on-going developments and future trends is given. A case-study is detailed. Other types of robotic help in the medical environment (such as for assisting a handicapped person, for rehabilitation of a patient or for replacement of some damaged/suppressed limbs or organs) are out of the scope of this chapter.Comment: Handbook of Automation, Shimon Nof (Ed.) (2009) 000-00

    Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review

    Get PDF
    Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.Web of Science1923art. no. 519

    Robot Autonomy for Surgery

    Full text link
    Autonomous surgery involves having surgical tasks performed by a robot operating under its own will, with partial or no human involvement. There are several important advantages of automation in surgery, which include increasing precision of care due to sub-millimeter robot control, real-time utilization of biosignals for interventional care, improvements to surgical efficiency and execution, and computer-aided guidance under various medical imaging and sensing modalities. While these methods may displace some tasks of surgical teams and individual surgeons, they also present new capabilities in interventions that are too difficult or go beyond the skills of a human. In this chapter, we provide an overview of robot autonomy in commercial use and in research, and present some of the challenges faced in developing autonomous surgical robots

    Factors influencing wider acceptance of Computer Assisted Orthopaedic Surgery (CAOS) technologies for Total Joint Arthroplasty

    Get PDF
    Computer-assisted orthopaedic surgery (CAOS) promises to improve outcomes of joint arthroplasty through better alignment and orientation of implants, but take up has so far been modest. Following an overview of CAOS technologies covering image-guided surgery, image-free and robotic systems, several factors for lack of penetration are identified. These include poor validation of accuracy, lack of standardisation, inappropriate clinical outcomes measures for assessing and comparing technologies, unresolved debate about the effectiveness of minimally invasive surgery, and issues of medical device regulations, cost, autonomy of surgeons to choose equipment, ergonomics and training. The paper concludes that dialogue between surgeons and manufacturers is needed to develop standardised measurements and outcomes scoring systems that are more appropriate for technology comparisons, and encourages an increased awareness of user requirements

    A simulation-enhanced intraoperative planning tool for robotic-assisted total knee arthroplasty

    Get PDF
    The purpose of the present study was to investigate current methods of surgical planning used in conjunction with robotics-assisted total knee arthroplasty (raTKA) to determine if improvements could be made using advanced computational techniques. Thus, through the use of musculoskeletal multi-body dynamic simulations, an enhanced surgical planning tool was developed, which provides insight on active postoperative joint mechanics. Development of the tool relied on patient-specific simulations using single-leg and full-body models. These simulations were constructed using two publicly-available datasets (Orthoload and SimTK); in particular, joint loading data obtained from subjects during various activities. Simulation parameters were optimized using a design-of experiments (DOE) methodology and validation of each of the models was conducted by calculating the root mean square error (RMSE) between joint loading calculated using the model and the corresponding results given in the appropriate dataset. Optimized and validated variants of each of the models were used in conjunction with the results of DOE studies that characterized the influence of a number of surgical planning variables on various biomechanical responses and linear regression analysis to derive knee performance equations (KPEs). In literature studies, some of the aforementioned responses have been strongly correlated with two outcomes commonly reported by dissatisfied TKA patients, namely, anterior knee pain and poor proprioception. In a proof-of-concept study, KPEs were used to calculate optimal positions and orientations of the femoral and tibial components in the case of one subject featured in the SimTK dataset. These results differed from corresponding ones reportedly achieved for the implant components in the subject. This trend suggests there is potential to improve robotic surgical planning for current-generation raTKA systems through the use of musculoskeletal simulation. Use of the proposed surgical planning tool does not require computational resources beyond what are used with a specified current-generation raTKA system (Navio Surgical System). Furthermore, there are only minimal differences between the workflow involving the proposed planning tool and that when Navio Surgical System is used. A number of recommendations for future studies are made, such as larger scale simulation validation work and use of more complex regression techniques when deriving the KPEs

    The Effect of Robotic Technology on Perioperative Outcomes in Total Knee Arthroplasty

    Get PDF
    Introduction Robotic technology has recently regained momentum in total knee arthroplasty (TKA) but the effects of this technology on accuracy of implant positioning, intraoperative soft tissue injury and postoperative functional rehabilitation remain unknown. The objectives of this research thesis were to compare a comprehensive range of radiological objectives and perioperative outcomes in conventional jig-based TKA versus robotic-arm assisted TKA, and use optical motion capture technology to quantify the effects of anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) resection on knee biomechanics. Methods A series of prospective cohort studies were undertaken in patients with established knee osteoarthritis undergoing primary conventional jig-based TKA versus robotic-arm assisted TKA. Predefined radiological and perioperative study outcomes were recorded by independent observers. Optical motion capture technology during robotic TKA was used to quantify the effects of ACL and PCL resection on knee biomechanics. Results Robotic-arm assisted TKA was associated with improved accuracy of implant positioning, reduced periarticular soft tissue injury, decreased bone trauma, improved postoperative functional rehabilitation, and reduced early systemic inflammatory response compared to conventional jig-based TKA. The Macroscopic Soft Tissue Injury (MASTI) classification system was developed and validated for grading intraoperative periarticular soft tissue injury and bone trauma during TKA. ACL resection created flexion-extension mismatch by increasing the extension gap more than the flexion gap, whilst PCL resection increased the flexion gap proportionally more than the extension gap and created mediolateral laxity in knee flexion but not in extension. Conclusion Robotic-arm assisted TKA was associated with increased accuracy of implant positioning, reduced iatrogenic soft tissue injury, and improved functional rehabilitation compared to conventional jig-based TKA. ACL and PCL resections created unique changes in knee biomechanics that affected flexion-extension gaps and mediolateral soft tissue tension during TKA. On the basis of this thesis, further clinical trials have been established to determine the long-term clinical significance of these findings

    Clinical application of robotic orthopedic surgery: a bibliometric study

    Get PDF
    Objectives: The present study aimed to evaluate the status and trends of robotic orthopedic surgery in a clinical setting using bibliometrics. Methods: All relevant publications on the clinical use of robotic surgery in orthopedics were searched from the Web of Science database. Subsequently, data were analyzed using bibliometrics. Visualizing data of bibliographic coupling, co-citation, and co-occurrence analysis were performed using VOSviewer. Results: In total, 224 clinical studies met the included standards between 2000 to 2019. Global publications presented an increasing annual trend, with the United States found to have the largest number of publications and robotic companies active in the field (n = 99), followed by China (n = 38), and the United Kingdom (n = 27). The institution with the most contributions was the Beijing Jishuitan Hospital in China (n = 15). The most productive scholars were Tian Wei and Mont Michael A, with 14 publications each. The top 30 most cited papers list showed 29 publications to be cited on more than 40 occassions. The journal with the most related and influential publications on robotic orthopedic surgery was the Journal of Arthroplasty. Fourteen types of robots were used, with the majority applied in knee and spinal surgery. MAKO was the most widely used robot in hip and knee surgery and Mazor in spinal surgery. Most studies were small sample populations of low-quality in this field. The top 20 most frequently used keywords were identified from 950 author keywords. Research on orthopedic robots were classified into two clusters by co-occurrence networks: spinal-related robotic surgery and joint-related robotic surgery. Conclusions: The present bibliometric study summarizes the clinical research of orthopedic robots on study type, sample size, type of surgery, robot information, surgical site, most popular keywords, most cited papers, journals, authors, institutions, and countries. These findings may assist the scholars better understand the current status and research trends to guide future practice and directions

    Computer Assisted Orthopedic Surgery in TKA

    Get PDF

    Feasibility study of a hand guided robotic drill for cochleostomy

    Get PDF
    The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper reports development studies of the hand guided robotic drill where the same consistent outcomes, augmentation of surgeon control and skill, and similar reduction of induced disturbances on the hearing organ are achieved. The device operates with differing presentation of tissues resulting from variation in anatomy and demonstrates the ability to control or avoid penetration of tissue layers as required and to respond to intended rather than involuntary motion of the surgeon operator. The advantage of hand guided over an arm supported system is that it offers flexibility in adjusting the drilling trajectory. This can be important to initiate cutting on a hard convex tissue surface without slipping and then to proceed on the desired trajectory after cutting has commenced. The results for trials on phantoms show that drill unit compliance is an important factor in the design
    corecore