85 research outputs found

    Sensory Feedback Device for Myoelectric Prosthetic Hand

    Get PDF
    In this work, a sensory feedback device for myoelectric prosthetic hand was developed to enhance the quality of life (QOL) of myoelectric prosthetic hand users. Two types of sensory feedback, namely, force sense feedback and temperature sense feedback, were proposed. As for the feedback device of force sense, the device is mounted on the user’s upper arm and provides hardness of the object onto the upper arm by winding a belt using a motor. On the other hand, as for the feedback device of temperature sense, the device is mounted on the user’s upper arm and presents temperature of the object onto the upper arm using a Peltier element. Finally, two-sensory feedback devices were united, and a two-sensory feedback device was built

    A Review of Non-Invasive Haptic Feedback stimulation Techniques for Upper Extremity Prostheses

    Get PDF
    A sense of touch is essential for amputees to reintegrate into their social and work life. The design of the next generation of the prostheses will have the ability to effectively convey the tactile information between the amputee and the artificial limbs. This work reviews non-invasive haptic feedback stimulation techniques to convey the tactile information from the prosthetic hand to the amputee’s brain. Various types of actuators that been used to stimulate the patient’s residual limb for different types of artificial prostheses in previous studies have been reviewed in terms of functionality, effectiveness, wearability and comfort. The non-invasive hybrid feedback stimulation system was found to be better in terms of the stimulus identification rate of the haptic prostheses’ users. It can be conclude that integrating hybrid haptic feedback stimulation system with the upper limb prostheses leads to improving its acceptance among users

    Sensors for Robotic Hands: A Survey of State of the Art

    Get PDF
    Recent decades have seen significant progress in the field of artificial hands. Most of the surveys, which try to capture the latest developments in this field, focused on actuation and control systems of these devices. In this paper, our goal is to provide a comprehensive survey of the sensors for artificial hands. In order to present the evolution of the field, we cover five year periods starting at the turn of the millennium. At each period, we present the robot hands with a focus on their sensor systems dividing them into categories, such as prosthetics, research devices, and industrial end-effectors.We also cover the sensors developed for robot hand usage in each era. Finally, the period between 2010 and 2015 introduces the reader to the state of the art and also hints to the future directions in the sensor development for artificial hands

    Touching on elements for a non-invasive sensory feedback system for use in a prosthetic hand

    Get PDF
    Hand amputation results in the loss of motor and sensory functions, impacting activities of daily life and quality of life. Commercially available prosthetic hands restore the motor function but lack sensory feedback, which is crucial to receive information about the prosthesis state in real-time when interacting with the external environment. As a supplement to the missing sensory feedback, the amputee needs to rely on visual and audio cues to operate the prosthetic hand, which can be mentally demanding. This thesis revolves around finding potential solutions to contribute to an intuitive non-invasive sensory feedback system that could be cognitively less burdensome and enhance the sense of embodiment (the feeling that an artificial limb belongs to one’s own body), increasing acceptance of wearing a prosthesis.A sensory feedback system contains sensors to detect signals applied to the prosthetics. The signals are encoded via signal processing to resemble the detected sensation delivered by actuators on the skin. There is a challenge in implementing commercial sensors in a prosthetic finger. Due to the prosthetic finger’s curvature and the fact that some prosthetic hands use a covering rubber glove, the sensor response would be inaccurate. This thesis shows that a pneumatic touch sensor integrated into a rubber glove eliminates these errors. This sensor provides a consistent reading independent of the incident angle of stimulus, has a sensitivity of 0.82 kPa/N, a hysteresis error of 2.39±0.17%, and a linearity error of 2.95±0.40%.For intuitive tactile stimulation, it has been suggested that the feedback stimulus should be modality-matched with the intention to provide a sensation that can be easily associated with the real touch on the prosthetic hand, e.g., pressure on the prosthetic finger should provide pressure on the residual limb. A stimulus should also be spatially matched (e.g., position, size, and shape). Electrotactile stimulation has the ability to provide various sensations due to it having several adjustable parameters. Therefore, this type of stimulus is a good candidate for discrimination of textures. A microphone can detect texture-elicited vibrations to be processed, and by varying, e.g., the median frequency of the electrical stimulation, the signal can be presented on the skin. Participants in a study using electrotactile feedback showed a median accuracy of 85% in differentiating between four textures.During active exploration, electrotactile and vibrotactile feedback provide spatially matched modality stimulations, providing continuous feedback and providing a displaced sensation or a sensation dispatched on a larger area. Evaluating commonly used stimulation modalities using the Rubber Hand Illusion, modalities which resemble the intended sensation provide a more vivid illusion of ownership for the rubber hand.For a potentially more intuitive sensory feedback, the stimulation can be somatotopically matched, where the stimulus is experienced as being applied on a site corresponding to their missing hand. This is possible for amputees who experience referred sensation on their residual stump. However, not all amputees experience referred sensations. Nonetheless, after a structured training period, it is possible to learn to associate touch with specific fingers, and the effect persisted after two weeks. This effect was evaluated on participants with intact limbs, so it remains to evaluate this effect for amputees.In conclusion, this thesis proposes suggestions on sensory feedback systems that could be helpful in future prosthetic hands to (1) reduce their complexity and (2) enhance the sense of body ownership to enhance the overall sense of embodiment as an addition to an intuitive control system

    Tactile sensing and feedback in SEMG hand

    Get PDF

    A hybrid haptic stimulation prosthetic wearable device to recover the missing sensation of the upper limb amputees

    Get PDF
    A hybrid haptic feedback stimulation system that is capable in sensing the contact pressure, the surface texture, and the temperature, simultaneously, was designed for a prosthetic hand to provide a tactile sensation to amputation patients. In addition, the haptic system was developed to enable the prosthetic’s users to implement withdrawal reflexes due to the thermal noxious stimulus in a quick manner. The re-sensation is achieved by non-invasively stimulating the skin of the patients’ residual limbs, based on the type and the level of tactile signals provided by the sensory system of the prostheses. Accordingly, three stages of design and development were performed to satisfy the research methodology. A vibrotactile prosthetic device, which is designed for the detection of contact pressure and surface texture in upper extremity, represents. While, the design of a novel wearable hybrid pressure-vibration haptic feedback stimulation device for conveying the tactile information regarding the contact pressure between the prosthetic hand and the grasped objects represents the second methodology stage. Lastly, the third stage was achieved by designing a novel hybrid pressure-vibration-temperature feedback stimulation system to provide a huge information regarding the prostheses environment to the users without brain confusing or requiring long pre-training. The main contribution of this work is the development and evaluation of the first step of a novel approach for a lightweight, 7 Degrees-Of-Freedom (DOF) tactile prosthetic arm to perform an effective as well as fast object manipulation and grasping. Furthermore, this study investigates the ability to convey the tactile information about the contact pressure, surface texture, and object temperature to the amputees with high identification accuracy by mean of using the designed hybrid pressure-vibration-temperature feedback wearable device. An evaluation of sensation and response has been conducted on forty healthy volunteers to evaluate the ability of the haptic system to stimulate the human nervous system. The results in term of Stimulus Identification Rate (SIR) show that all the volunteers were correctly able to discriminate the sensation of touch, start of touch, end of touch, and grasping objects. While 94%, 96%, 97%, and 95.24% of the entire stimuli were successfully identified by the volunteers during the experiments of slippage, pressure level, surface texture, and temperature, respectively. The position tracking controller system was designed to synchronize the movements of the volunteers’ elbow joints and the prosthetic’s elbow joint to record the withdrawal reflexes. The results verified the ability of the haptic system to excite the human brain at the abnormal noxious stimulus and enable the volunteers to perform a quick withdrawal reflex within 0.32 sec. The test results and the volunteers' response established evidence that amputees are able to recover their sense of the contact pressure, the surface texture, and the object temperature as well as to perform thermal withdrawal reflexes using the solution developed in this work

    Novel Bidirectional Body - Machine Interface to Control Upper Limb Prosthesis

    Get PDF
    Objective. The journey of a bionic prosthetic user is characterized by the opportunities and limitations involved in adopting a device (the prosthesis) that should enable activities of daily living (ADL). Within this context, experiencing a bionic hand as a functional (and, possibly, embodied) limb constitutes the premise for mitigating the risk of its abandonment through the continuous use of the device. To achieve such a result, different aspects must be considered for making the artificial limb an effective support for carrying out ADLs. Among them, intuitive and robust control is fundamental to improving amputees’ quality of life using upper limb prostheses. Still, as artificial proprioception is essential to perceive the prosthesis movement without constant visual attention, a good control framework may not be enough to restore practical functionality to the limb. To overcome this, bidirectional communication between the user and the prosthesis has been recently introduced and is a requirement of utmost importance in developing prosthetic hands. Indeed, closing the control loop between the user and a prosthesis by providing artificial sensory feedback is a fundamental step towards the complete restoration of the lost sensory-motor functions. Within my PhD work, I proposed the development of a more controllable and sensitive human-like hand prosthesis, i.e., the Hannes prosthetic hand, to improve its usability and effectiveness. Approach. To achieve the objectives of this thesis work, I developed a modular and scalable software and firmware architecture to control the Hannes prosthetic multi-Degree of Freedom (DoF) system and to fit all users’ needs (hand aperture, wrist rotation, and wrist flexion in different combinations). On top of this, I developed several Pattern Recognition (PR) algorithms to translate electromyographic (EMG) activity into complex movements. However, stability and repeatability were still unmet requirements in multi-DoF upper limb systems; hence, I started by investigating different strategies to produce a more robust control. To do this, EMG signals were collected from trans-radial amputees using an array of up to six sensors placed over the skin. Secondly, I developed a vibrotactile system to implement haptic feedback to restore proprioception and create a bidirectional connection between the user and the prosthesis. Similarly, I implemented an object stiffness detection to restore tactile sensation able to connect the user with the external word. This closed-loop control between EMG and vibration feedback is essential to implementing a Bidirectional Body - Machine Interface to impact amputees’ daily life strongly. For each of these three activities: (i) implementation of robust pattern recognition control algorithms, (ii) restoration of proprioception, and (iii) restoration of the feeling of the grasped object's stiffness, I performed a study where data from healthy subjects and amputees was collected, in order to demonstrate the efficacy and usability of my implementations. In each study, I evaluated both the algorithms and the subjects’ ability to use the prosthesis by means of the F1Score parameter (offline) and the Target Achievement Control test-TAC (online). With this test, I analyzed the error rate, path efficiency, and time efficiency in completing different tasks. Main results. Among the several tested methods for Pattern Recognition, the Non-Linear Logistic Regression (NLR) resulted to be the best algorithm in terms of F1Score (99%, robustness), whereas the minimum number of electrodes needed for its functioning was determined to be 4 in the conducted offline analyses. Further, I demonstrated that its low computational burden allowed its implementation and integration on a microcontroller running at a sampling frequency of 300Hz (efficiency). Finally, the online implementation allowed the subject to simultaneously control the Hannes prosthesis DoFs, in a bioinspired and human-like way. In addition, I performed further tests with the same NLR-based control by endowing it with closed-loop proprioceptive feedback. In this scenario, the results achieved during the TAC test obtained an error rate of 15% and a path efficiency of 60% in experiments where no sources of information were available (no visual and no audio feedback). Such results demonstrated an improvement in the controllability of the system with an impact on user experience. Significance. The obtained results confirmed the hypothesis of improving robustness and efficiency of a prosthetic control thanks to of the implemented closed-loop approach. The bidirectional communication between the user and the prosthesis is capable to restore the loss of sensory functionality, with promising implications on direct translation in the clinical practice

    A strengthened and sensorised custom silicone glove for use with an intelligent prosthetic hand

    Get PDF
    External gloves for anthropomorphic prosthetic hands protect the mechanisms from damage and ingress of contaminants and can be used to create a pleasing, life-like appearance. The properties of the glove material are the result of a compromise between the resistance to damage and flexibility. Silicone gloves are easier to flex and keep clean, but also more easily damaged. This paper details the use of nanoclay fillers to enhance the properties of silicone, successfully increasing strength whilst maintaining flexibility. The performance of the enhanced silicone is as robust and resistant to tear and puncture as commercial gloves, while being more flexible. This flexibility makes the incorporation of a piezo-electric pressure sensor based on the EEonyx conductive fabric, practical. A sandwich of the cloth and copper fabric creates the sensor, which decreases in resistance with increasing pressure. The sensors are characterised and production variability within the silicone are tested. Three sensors are incorporated into a glove made to fit around a Southampton Intelligent Hand. The hand adapts its grip shape and force depending on the object held. The technology is adaptable and it can be incorporated in a glove produced to fit any prosthetic hand. <br/

    The SmartHand transradial prosthesis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Prosthetic components and control interfaces for upper limb amputees have barely changed in the past 40 years. Many transradial prostheses have been developed in the past, nonetheless most of them would be inappropriate if/when a large bandwidth human-machine interface for control and perception would be available, due to either their limited (or inexistent) sensorization or limited dexterity. <it>SmartHand </it>tackles this issue as is meant to be clinically experimented in amputees employing different neuro-interfaces, in order to investigate their effectiveness. This paper presents the design and on bench evaluation of the SmartHand.</p> <p>Methods</p> <p>SmartHand design was bio-inspired in terms of its physical appearance, kinematics, sensorization, and its multilevel control system. Underactuated fingers and differential mechanisms were designed and exploited in order to fit all mechatronic components in the size and weight of a natural human hand. Its sensory system was designed with the aim of delivering significant afferent information to the user through adequate interfaces.</p> <p>Results</p> <p>SmartHand is a five fingered self-contained robotic hand, with 16 degrees of freedom, actuated by 4 motors. It integrates a bio-inspired sensory system composed of 40 proprioceptive and exteroceptive sensors and a customized embedded controller both employed for implementing automatic grasp control and for potentially delivering sensory feedback to the amputee. It is able to perform everyday grasps, count and independently point the index. The weight (530 g) and speed (closing time: 1.5 seconds) are comparable to actual commercial prostheses. It is able to lift a 10 kg suitcase; slippage tests showed that within particular friction and geometric conditions the hand is able to stably grasp up to 3.6 kg cylindrical objects.</p> <p>Conclusions</p> <p>Due to its unique embedded features and human-size, the SmartHand holds the promise to be experimentally fitted on transradial amputees and employed as a bi-directional instrument for investigating -during realistic experiments- different interfaces, control and feedback strategies in neuro-engineering studies.</p
    • …
    corecore