8 research outputs found
Bio-Inspired Soft Artificial Muscles for Robotic and Healthcare Applications
Soft robotics and soft artificial muscles have emerged as prolific research areas and have gained substantial traction over the last two decades. There is a large paradigm shift of research interests in soft artificial muscles for robotic and medical applications due to their soft, flexible and compliant characteristics compared to rigid actuators. Soft artificial muscles provide safe human-machine interaction, thus promoting their implementation in medical fields such as wearable assistive devices, haptic devices, soft surgical instruments and cardiac compression devices. Depending on the structure and material composition, soft artificial muscles can be controlled with various excitation sources, including electricity, magnetic fields, temperature and pressure.
Pressure-driven artificial muscles are among the most popular soft actuators due to their fast response, high exertion force and energy efficiency. Although significant progress has been made, challenges remain for a new type of artificial muscle that is easy to manufacture, flexible, multifunctional and has a high length-to-diameter ratio. Inspired by human muscles, this thesis proposes a soft, scalable, flexible, multifunctional, responsive, and high aspect ratio hydraulic filament artificial muscle (HFAM) for robotic and medical applications. The HFAM consists of a silicone tube inserted inside a coil spring, which expands longitudinally when receiving positive hydraulic pressure. This simple fabrication method enables low-cost and mass production of a wide range of product sizes and materials. This thesis investigates the characteristics of the proposed HFAM and two implementations, as a wearable soft robotic glove to aid in grasping objects, and as a smart surgical suture for perforation closure. Multiple HFAMs are also combined by twisting and braiding techniques to enhance their performance.
In addition, smart textiles are created from HFAMs using traditional knitting and weaving techniques for shape-programmable structures, shape-morphing soft robots and smart compression devices for massage therapy. Finally, a proof-of-concept robotic cardiac compression device is developed by arranging HFAMs in a special configuration to assist in heart failure treatment.
Overall this fundamental work contributes to the development of soft artificial muscle technologies and paves the way for future comprehensive studies to develop HFAMs for specific medical and robotic requirements
Recommended from our members
Soft-Material Robotics
There has been a boost of research activities in robotics using soft materials in the past ten years. It is expected that the use and control of soft materials can help realize robotic systems that are safer, cheaper, and more adaptable than the level that the conventional rigid-material robots can achieve. Contrary to a number of existing review and position papers on soft-material robotics, which mostly present case studies and/or discuss trends and challenges, the review focuses on the fundamentals of the research field. First, it gives a definition of softmaterial robotics and introduces its history, which dates back to the late 1970s. Second, it provides characterization of soft-materials, actuators and sensing elements. Third, it presents two general approaches to mathematical modelling of kinematics of soft-material robots; that is, piecewise constant curvature approximation and variable curvature approach, as well as their related statics and dynamics. Fourth, it summarizes control methods that have been used for soft-material robots and other continuum robots in both model-based fashion and model-free fashion. Lastly, applications or potential usage of soft-material robots are described related to wearable robots, medical robots, grasping and manipulation
Development of a Novel Amphibious Locomotion System for use in Intra-Luminal Surgical Procedures
Colonoscopy is widely considered the gold standard for inspection of the colon. The procedure is however not without issue, current colonoscopes have seen little change or innovation throughout their 40 years of use with patient discomfort still limiting success. The aim of this PhD study was to develop a locomotion system for use on a robotic device that can traverse a liquid filled colon for atraumatic inspection and biopsy tasks. The PhD was undertaken as part of a larger two-centre EU project, which aimed to bring about a change in the way colonoscopy is done by moving to “robotic hydro-colonoscopy”.
In this thesis the initial development and testing of an amphibious locomotion concept for use in a procedure known as hydro-colonoscopy is described. The locomotion system is comprised of four Archimedes’ screws arranged in two counter-rotating pairs. These aim to provide propulsion through a fluid-filled colon as well as provide locomotive traction against colonic tissue in partially fluid-filled or collapsed sections of the colon, such as the splenic flexure.
Experimental studies were carried out on a single screw system in fluid and dual counter-rotating screws in contact conditions. These show the system’s ability to generate thrust in the two discrete modes of locomotion of the amphibious system.
A 2:1 scale prototype of the proposed device was produced and features compliant screw threads to provide atraumatic locomotion. The scale prototype device was tested in ex-vivo porcine colon. The developed system was able to traverse through lumen to limited success, which demonstrated that this concept has the potential for use on an intra-luminal robotic device
The key contributions of this research are: variable geometry locomotion system; amphibious locomotion using Archimedes’ screws; experimental assessment of the locomotion in fluid, contact and amphibious states; and analysis of the contact dynamics against tissue
Design and Analysis of Exaggerated Rectilinear Gait-Based Snake-Inspired Robots
Snake-inspired locomotion is much more maneuverable compared to conventional locomotion concepts and it enables a robot to navigate through rough terrain. A rectilinear gait is quite flexible and has the following benefits: functionality on a wide variety of terrains, enables a highly stable robot platform, and provides pure undulatory motion without passive wheels. These benefits make rectilinear gaits especially suitable for search and rescue applications. However, previous robot designs utilizing rectilinear gaits were slow in speed and required considerable vertical motion. This dissertation will explore the development and implementation of a new exaggerated rectilinear gait that which will enable high speed locomotion and more efficient operation in a snake-inspired robot platform. The exaggerated rectilinear gait will emulate the natural snake's rectilinear gait to gain the benefit a snake's terrain adaptability, but the sequence and range of joint motion will be greatly exaggerated to achieve higher velocities to support robot speeds within the range of human walking speed.
The following issues will be investigated in this dissertation. First, this dissertation will address the challenge of developing a snake-inspired robot capable of executing exaggerated rectilinear gaits. To successfully execute the exaggerated rectilinear gait, a snake-inspired robot platform must be able to perform high speed linear expansion/contraction and pivoting motions between segments. In addition to high speed joint motion, the new mechanical architecture much also incorporate a method for providing positive traction during gait execution. Second, a new exaggerated gait dynamics model will be developed using well established kinematics and dynamics analysis techniques. In addition to the exaggerated rectilinear gaits which emphasize high speed, a set of exaggerated rectilinear gaits which emphasize high traction will also be developed for application on difficult terrain types. Finally, an exaggerated rectilinear that emphasizes energy efficiency is defined and analyzed. This dissertation provides the foundations for realizing a high speed limbless locomotion capable of meeting the needs of the search, rescue, and recovery applications
An analysis of the locomotory behaviour and functional morphology of errant polychaetes
EThOS - Electronic Theses Online ServiceGBUnited Kingdo
Towards tactile sensing active capsule endoscopy
Examination of the gastrointestinal(GI) tract has traditionally been performed using tethered endoscopy tools with limited reach and more recently with passive untethered capsule endoscopy with limited capability. Inspection of small intestines is only possible using the latter capsule endoscopy with on board camera system. Limited to visual means it cannot detect features beneath the lumen wall if they have not affected the lumen structure or colour. This work presents an improved capsule endoscopy system with locomotion for active exploration of the small intestines and tactile sensing to detect deformation of the capsule outer surface when it follows the intestinal wall. In laboratory conditions this system is capable of identifying sub-lumen features such as submucosal tumours.Through an extensive literary review the current state of GI tract inspection in particular using remote operated miniature robotics, was investigated, concluding no solution currently exists that utilises tactile sensing with a capsule endoscopy. In order to achieve such a platform, further investigation was made in to tactile sensing technologies, methods of locomotion through the gut, and methods to support an increased power requirement for additional electronics and actuation. A set of detailed criteria were compiled for a soft formed sensor and flexible bodied locomotion system. The sensing system is built on the biomimetic tactile sensing device, Tactip, \cite{Chorley2008, Chorley2010, Winstone2012, Winstone2013} which has been redesigned to fit the form of a capsule endoscopy. These modifications have required a cylindrical sensing surface with panoramic optical system. Multi-material 3D printing has been used to build an almost complete sensor assembly with a combination of hard and soft materials, presenting a soft compliant tactile sensing system that mimics the tactile sensing methods of the human finger. The cylindrical Tactip has been validated using artificial submucosal tumours in laboratory conditions. The first experiment has explored the new form factor and measured the device's ability to detect surface deformation when travelling through a pipe like structure with varying lump obstructions. Sensor data was analysed and used to reconstruct the test environment as a 3D rendered structure. A second tactile sensing experiment has explored the use of classifier algorithms to successfully discriminate between three tumour characteristics; shape, size and material hardness. Locomotion of the capsule endoscopy has explored further bio-inspiration from earthworm's peristaltic locomotion, which share operating environment similarities. A soft bodied peristaltic worm robot has been developed that uses a tuned planetary gearbox mechanism to displace tendons that contract each worm segment. Methods have been identified to optimise the gearbox parameter to a pipe like structure of a given diameter. The locomotion system has been tested within a laboratory constructed pipe environment, showing that using only one actuator, three independent worm segments can be controlled. This configuration achieves comparable locomotion capabilities to that of an identical robot with an actuator dedicated to each individual worm segment. This system can be miniaturised more easily due to reduced parts and number of actuators, and so is more suitable for capsule endoscopy. Finally, these two developments have been integrated to demonstrate successful simultaneous locomotion and sensing to detect an artificial submucosal tumour embedded within the test environment. The addition of both tactile sensing and locomotion have created a need for additional power beyond what is available from current battery technology. Early stage work has reviewed wireless power transfer (WPT) as a potential solution to this problem. Methods for optimisation and miniaturisation to implement WPT on a capsule endoscopy have been identified with a laboratory built system that validates the methods found. Future work would see this combined with a miniaturised development of the robot presented. This thesis has developed a novel method for sub-lumen examination. With further efforts to miniaturise the robot it could provide a comfortable and non-invasive procedure to GI tract inspection reducing the need for surgical procedures and accessibility for earlier stage of examination. Furthermore, these developments have applicability in other domains such as veterinary medicine, industrial pipe inspection and exploration of hazardous environments