40 research outputs found

    INVESTIGATION OF OCULAR ARTEFACTS IN THE HUMAN EEG AND THEIR REMOVAL BY A MICROPROCESSOR-BASED INSTRUMENT

    Get PDF
    The Electroencephalogram (EEG) is widely used in clinical and psychological situations, but it is often seriously obscured by ocular artefacts (OAs) resulting from movements in the ocular system (eyeball, eyelids etc). 'The work described in this thesis is concerned with the problems of OAs in the human EEG, their removal both off-line and on-line, and the design and development of an on-line OA removal system, together with a critical review of the literature on the subject. The work of Jervis and his co-workers was extended to further study OAs, to obtain improved measures of the effectiveness of OA removal, and to find the most effective model for removing OA on-line. A number of criteria were devised to compare the performance of several models, including a more reliable pictorial method. It was found unnecessary to use the vertical and horizontal EOGs for both eyes (ie. four EOGs) in a removal model, as previously reported. This was shown to be due to strong correlation between the EOGs. It was shown that the assumption of uncorrelated error terms, implicit in present removal models, is invalid. To remedy this, the error terms were modelled as an autoregressive series. New on-line removal algorithms based on numerically stable factorization algorithms were developed. Compared to the present on-line methods the algorithms are superior, requiring no subjective manual adjustments, or the co-operation of subjects which cannot always be guarranteed. The algorithms were shown to give similar results to their off-line equivalents. A simpler algorithm based on the present on-line method is also proposed as an alternative, but may lead to a reduced performance. An important part of this research lay in the application of the results to the design and development of a new automatic OA removal system utilizing the algorithms described above.Department of Neurological Sciences, Freedom Fields Hospital, Plymout

    Systems engineering approaches to safety in transport systems

    Get PDF
    openDuring driving, driver behavior monitoring may provide useful information to prevent road traffic accidents caused by driver distraction. It has been shown that 90% of road traffic accidents are due to human error and in 75% of these cases human error is the only cause. Car manufacturers have been interested in driver monitoring research for several years, aiming to enhance the general knowledge of driver behavior and to evaluate the functional state as it may drastically influence driving safety by distraction, fatigue, mental workload and attention. Fatigue and sleepiness at the wheel are well known risk factors for traffic accidents. The Human Factor (HF) plays a fundamental role in modern transport systems. Drivers and transport operators control a vehicle towards its destination in according to their own sense, physical condition, experience and ability, and safety strongly relies on the HF which has to take the right decisions. On the other hand, we are experiencing a gradual shift towards increasingly autonomous vehicles where HF still constitutes an important component, but may in fact become the "weakest link of the chain", requiring strong and effective training feedback. The studies that investigate the possibility to use biometrical or biophysical signals as data sources to evaluate the interaction between human brain activity and an electronic machine relate to the Human Machine Interface (HMI) framework. The HMI can acquire human signals to analyse the specific embedded structures and recognize the behavior of the subject during his/her interaction with the machine or with virtual interfaces as PCs or other communication systems. Based on my previous experience related to planning and monitoring of hazardous material transport, this work aims to create control models focused on driver behavior and changes of his/her physiological parameters. Three case studies have been considered using the interaction between an EEG system and external device, such as driving simulators or electronical components. A case study relates to the detection of the driver's behavior during a test driver. Another case study relates to the detection of driver's arm movements according to the data from the EEG during a driver test. The third case is the setting up of a Brain Computer Interface (BCI) model able to detect head movements in human participants by EEG signal and to control an electronic component according to the electrical brain activity due to head turning movements. Some videos showing the experimental results are available at https://www.youtube.com/channel/UCj55jjBwMTptBd2wcQMT2tg.openXXXIV CICLO - INFORMATICA E INGEGNERIA DEI SISTEMI/ COMPUTER SCIENCE AND SYSTEMS ENGINEERING - Ingegneria dei sistemiZero, Enric

    Independent EEG Sources Are Dipolar

    Get PDF
    Independent component analysis (ICA) and blind source separation (BSS) methods are increasingly used to separate individual brain and non-brain source signals mixed by volume conduction in electroencephalographic (EEG) and other electrophysiological recordings. We compared results of decomposing thirteen 71-channel human scalp EEG datasets by 22 ICA and BSS algorithms, assessing the pairwise mutual information (PMI) in scalp channel pairs, the remaining PMI in component pairs, the overall mutual information reduction (MIR) effected by each decomposition, and decomposition ‘dipolarity’ defined as the number of component scalp maps matching the projection of a single equivalent dipole with less than a given residual variance. The least well-performing algorithm was principal component analysis (PCA); best performing were AMICA and other likelihood/mutual information based ICA methods. Though these and other commonly-used decomposition methods returned many similar components, across 18 ICA/BSS algorithms mean dipolarity varied linearly with both MIR and with PMI remaining between the resulting component time courses, a result compatible with an interpretation of many maximally independent EEG components as being volume-conducted projections of partially-synchronous local cortical field activity within single compact cortical domains. To encourage further method comparisons, the data and software used to prepare the results have been made available (http://sccn.ucsd.edu/wiki/BSSComparison)

    Enhancing brain-computer interfacing through advanced independent component analysis techniques

    No full text
    A Brain-computer interface (BCI) is a direct communication system between a brain and an external device in which messages or commands sent by an individual do not pass through the brain’s normal output pathways but is detected through brain signals. Some severe motor impairments, such as Amyothrophic Lateral Sclerosis, head trauma, spinal injuries and other diseases may cause the patients to lose their muscle control and become unable to communicate with the outside environment. Currently no effective cure or treatment has yet been found for these diseases. Therefore using a BCI system to rebuild the communication pathway becomes a possible alternative solution. Among different types of BCIs, an electroencephalogram (EEG) based BCI is becoming a popular system due to EEG’s fine temporal resolution, ease of use, portability and low set-up cost. However EEG’s susceptibility to noise is a major issue to develop a robust BCI. Signal processing techniques such as coherent averaging, filtering, FFT and AR modelling, etc. are used to reduce the noise and extract components of interest. However these methods process the data on the observed mixture domain which mixes components of interest and noise. Such a limitation means that extracted EEG signals possibly still contain the noise residue or coarsely that the removed noise also contains part of EEG signals embedded. Independent Component Analysis (ICA), a Blind Source Separation (BSS) technique, is able to extract relevant information within noisy signals and separate the fundamental sources into the independent components (ICs). The most common assumption of ICA method is that the source signals are unknown and statistically independent. Through this assumption, ICA is able to recover the source signals. Since the ICA concepts appeared in the fields of neural networks and signal processing in the 1980s, many ICA applications in telecommunications, biomedical data analysis, feature extraction, speech separation, time-series analysis and data mining have been reported in the literature. In this thesis several ICA techniques are proposed to optimize two major issues for BCI applications: reducing the recording time needed in order to speed up the signal processing and reducing the number of recording channels whilst improving the final classification performance or at least with it remaining the same as the current performance. These will make BCI a more practical prospect for everyday use. This thesis first defines BCI and the diverse BCI models based on different control patterns. After the general idea of ICA is introduced along with some modifications to ICA, several new ICA approaches are proposed. The practical work in this thesis starts with the preliminary analyses on the Southampton BCI pilot datasets starting with basic and then advanced signal processing techniques. The proposed ICA techniques are then presented using a multi-channel event related potential (ERP) based BCI. Next, the ICA algorithm is applied to a multi-channel spontaneous activity based BCI. The final ICA approach aims to examine the possibility of using ICA based on just one or a few channel recordings on an ERP based BCI. The novel ICA approaches for BCI systems presented in this thesis show that ICA is able to accurately and repeatedly extract the relevant information buried within noisy signals and the signal quality is enhanced so that even a simple classifier can achieve good classification accuracy. In the ERP based BCI application, after multichannel ICA the data just applied to eight averages/epochs can achieve 83.9% classification accuracy whilst the data by coherent averaging can reach only 32.3% accuracy. In the spontaneous activity based BCI, the use of the multi-channel ICA algorithm can effectively extract discriminatory information from two types of singletrial EEG data. The classification accuracy is improved by about 25%, on average, compared to the performance on the unpreprocessed data. The single channel ICA technique on the ERP based BCI produces much better results than results using the lowpass filter. Whereas the appropriate number of averages improves the signal to noise rate of P300 activities which helps to achieve a better classification. These advantages will lead to a reliable and practical BCI for use outside of the clinical laboratory

    ERP source tracking and localization from single trial EEG MEG signals

    Get PDF
    Electroencephalography (EEG) and magnetoencephalography (MEG), which are two of a number of neuroimaging techniques, are scalp recordings of the electrical activity of the brain. EEG and MEG (E/MEG) have excellent temporal resolution, they are easy to acquire, and have a wide range of applications in science, medicine and engineering. These valuable signals, however, suffer from poor spatial resolution and in many cases from very low signal to noise ratios. In this study, new computational methods for analyzing and improving the quality of E/MEG signals are presented. We mainly focus on single trial event-related potential (ERP) estimation and E/MEG dipole source localization. Several methods basically based on particle filtering (PF) are proposed. First, a method using PF for single trial estimation of ERP signals is considered. In this method, the wavelet coefficients of each ERP are assumed to be a Markovian process and do not change extensively across trials. The wavelet coefficients are then estimated recursively using PF. The results both for simulations and real data are compared with those of the well known Kalman Filtering (KF) approach. In the next method we move from single trial estimation to source localization of E/MEG signals. The beamforming (BF) approach for dipole source localization is generalized based on prior information about the noise. BF is in fact a spatial filter that minimizes the power of all the signals at the output of the filter except those that come from the locations of interest. In the proposed method, using two more constraints than in the classical BF formulation, the output noise powers are minimized and the interference activities are stopped.EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Development of nonlinear techniques based on time-frequency representation and information theory for the analysis of EEG signals to assess different states of consciousness

    Get PDF
    Electroencephalogram (EEG) recordings provide insight into the changes in brain activity associated with various states of anesthesia, epilepsy, brain attentiveness, sleep disorders, brain disorders, etc. EEG's are complex signals whose statistical properties depend on both space and time. Their randomness and non-stationary characteristics make them impossible to be described in an accurate way with a simple technique, requiring analysis and characterization involves techniques that take into account their non-stationarity. For that, new advanced techniques in order to improve the efficiency of the EEG based methods used in the clinical practice have to be developed. The main objective of this thesis was to investigate and implement different methods based on nonlinear techniques in order to develop indexes able to characterize the frequency spectrum, the nonlinear dynamics and the complexity of the EEG signals recorded in different state of consciousness. Firstly, a new method for removing peak and spike in biological signal based on the signal envelope was successfully designed and applied to simulated and real EEG signals, obtaining performances significantly better than the traditional adaptive filters. Then, several studies were carried out in order to extract and evaluate EEG measures based on nonlinear techniques in different contexts such as the automatic detection of sleepiness and the characterization and prediction of the nociceptive stimuli and the assessment of the sedation level. Four novel indexes were defined by calculating entropy of the Choi-Williams distribution (CWD) with respect to time or frequency, by using the probability mass function at each time instant taken independently or by using the probability mass function of the entire CWD. The values of these indexes tend to decrease, with different proportion, when the behavior of the signals evolved from chaos or randomness to periodicity and present differences when comparing EEG recorded in eyes-open and eyes-closed states and in ictal and non-ictal states. Measures obtained with time-frequency representation, mutual information function and correntropy, were applied to EEG signals for the automatic sleepiness detection in patients suffering sleep disorders. The group of patients with excessive daytime sleepiness presented more power in ¿ band than the group without sleepiness, which presented higher spectral and cross-spectral entropy in the frontal zone in d band. More complexity in the occipital zone was found in the group of patients without sleepiness in ß band, while a stronger nonlinear coupling between the occipital and frontal regions was detected in patients with excessive daytime sleepiness, in ß band. Time-frequency representation and non-linear measures were also used in order to study how adaptation and fatigue affect the event-related brain potentials to stimuli of different modalities. Differences between the responses to infrequent and frequent stimulation in different recording periods were found in series of averaged EEG epochs recorded after thermal, electrical and auditory stimulation. Nonlinear measures calculated on EEG filtered in the traditional frequency bands and in higher frequency bands improved the assessment of the sedation level. These measures were obtained by applying all the developed techniques on signals recorded from patients sedated, in order to predict the responses to pain stimulation such as nail bad compression and endoscopy tube insertion. The proposed measures exhibit better performances than the bispectral index (BIS), a traditional indexes used for hypnosis assessment. In conclusion, nonlinear measures based on time-frequency representation, mutual information functions and correntropy provided additional information that helped to improve the automatic sleepiness detection, the characterization and prediction of the nociceptive responses and thus the assessment of the sedation level.El registro de la señal Electroencefalografíca (EEG) proporciona información sobre los cambios en la actividad cerebral asociados con varios estados de la anestesia, la epilepsia, la atención cerebral, los trastornos del sueño, los trastornos cerebrales, etc. Los EEG son señales complejas cuyas propiedades estadísticas dependen del espacio y del tiempo. Sus características aleatorias y no estacionarias hacen imposible que el EEG se describa de forma precisa con una técnica sencilla requiriendo un análisis y una caracterización que implica técnicas que tengan en cuenta su no estacionariedad. Todo esto aumenta la necesidad de desarrollar nuevas técnicas avanzadas con el fin de mejorar la eficiencia de los métodos utilizados en la práctica clínica que son basados en el análisis de EEG. En esta tesis se han investigado y aplicado diferentes métodos utilizando técnicas no lineales con el fin de desarrollar índices capaces de caracterizar el espectro de frecuencias, la dinámica no lineal y la complejidad de las señales EEG registradas en diferentes estados de conciencia. En primer lugar, se ha desarrollado un nuevo algoritmo basado en la envolvente de la señal para la eliminación de ruido de picos en las señales biológicas. Este algoritmo ha sido aplicado a señales simuladas y reales obteniendo resultados significativamente mejores comparados con los filtros adaptativos tradicionales. Seguidamente, se han llevado a cabo varios estudios con el fin de extraer y evaluar las medidas de EEG basadas en técnicas no lineales en diferentes contextos. Se han definido nuevos índices mediante el cálculo de la entropía de la distribución de Choi-Williams (DCW) con respecto al tiempo o la frecuencia. Se ha observado que los valores de estos índices tienden a disminuir, en diferentes proporciones, cuando el comportamiento de las señales evoluciona de caótico o aleatorio a periódico. Además, se han encontrado valores diferentes de estos índices aplicados a la señal EEG registrada en diferentes estados. Diferentes medidas basadas en la representación tiempo-frecuencia, la función de información mutua y la correntropia se han aplicado al EEG para la detección automática de la somnolencia en pacientes que sufren trastornos del sueño. Se ha observado en la zona frontal que la potencia en la banda θ es mayor en los pacientes con somnolencia diurna excesiva, mientras que la entropía espectral y la entropía espectral cruzada en la banda δ es mayor en los pacientes sin somnolencia. En el grupo sin somnolencia se ha encontrado más complejidad en la zona occipital, mientras que el acoplamiento no lineal entre las regiones occipital y frontal ha resultado más fuerte en pacientes con somnolencia diurna excesiva, en la banda β. La representación tiempo-frecuencia y las medidas no lineales se han utilizado para estudiar cómo la adaptación y la fatiga afectan a los potenciales cerebrales relacionados con estímulos térmicos, eléctricos y auditivos. Analizando el promedio de varias épocas de EEG grabadas después de la estimulación, se han encontrado diferencias entre las respuestas a la estimulación frecuente e infrecuente en diferentes períodos de registro. Todas las técnicas que se han desarrollado, se han aplicado a señales EEG registradas en pacientes sedados, con el fin de predecir las respuestas a la estimulación del dolor. Un conjunto de medidas calculadas en señales EEG filtradas en diferentes bandas de frecuencia ha permitido mejorar la evaluación del nivel de sedación. Las medidas propuestas han presentado un mejor rendimiento comparado con el índice bispectral, un indicador de hipnosis tradicional. En conclusión, las medidas no lineales basadas en la representación tiempofrecuencia, funciones de información mutua y correntropia han proporcionado informaciones adicionales que contribuyeron a mejorar la detección automática de la somnolencia, la caracterización y predicción de las respuestas nociceptivas y por lo tanto la evaluación del nivel de sedación

    ERP source tracking and localization from single trial EEG MEG signals

    Get PDF
    Electroencephalography (EEG) and magnetoencephalography (MEG), which are two of a number of neuroimaging techniques, are scalp recordings of the electrical activity of the brain. EEG and MEG (E/MEG) have excellent temporal resolution, they are easy to acquire, and have a wide range of applications in science, medicine and engineering. These valuable signals, however, suffer from poor spatial resolution and in many cases from very low signal to noise ratios. In this study, new computational methods for analyzing and improving the quality of E/MEG signals are presented. We mainly focus on single trial event-related potential (ERP) estimation and E/MEG dipole source localization. Several methods basically based on particle filtering (PF) are proposed. First, a method using PF for single trial estimation of ERP signals is considered. In this method, the wavelet coefficients of each ERP are assumed to be a Markovian process and do not change extensively across trials. The wavelet coefficients are then estimated recursively using PF. The results both for simulations and real data are compared with those of the well known Kalman Filtering (KF) approach. In the next method we move from single trial estimation to source localization of E/MEG signals. The beamforming (BF) approach for dipole source localization is generalized based on prior information about the noise. BF is in fact a spatial filter that minimizes the power of all the signals at the output of the filter except those that come from the locations of interest. In the proposed method, using two more constraints than in the classical BF formulation, the output noise powers are minimized and the interference activities are stopped
    corecore