284 research outputs found

    Fluidic Fabric Muscle Sheets for Wearable and Soft Robotics

    Full text link
    Conformable robotic systems are attractive for applications in which they can be used to actuate structures with large surface areas, to provide forces through wearable garments, or to realize autonomous robotic systems. We present a new family of soft actuators that we refer to as Fluidic Fabric Muscle Sheets (FFMS). They are composite fabric structures that integrate fluidic transmissions based on arrays of elastic tubes. These sheet-like actuators can strain, squeeze, bend, and conform to hard or soft objects of arbitrary shapes or sizes, including the human body. We show how to design and fabricate FFMS actuators via facile apparel engineering methods, including computerized sewing techniques. Together, these determine the distributions of stresses and strains that can be generated by the FFMS. We present a simple mathematical model that proves effective for predicting their performance. FFMS can operate at frequencies of 5 Hertz or more, achieve engineering strains exceeding 100%, and exert forces greater than 115 times their own weight. They can be safely used in intimate contact with the human body even when delivering stresses exceeding 106^\text{6} Pascals. We demonstrate their versatility for actuating a variety of bodies or structures, and in configurations that perform multi-axis actuation, including bending and shape change. As we also show, FFMS can be used to exert forces on body tissues for wearable and biomedical applications. We demonstrate several potential use cases, including a miniature steerable robot, a glove for grasp assistance, garments for applying compression to the extremities, and devices for actuating small body regions or tissues via localized skin stretch.Comment: 32 pages, 10 figure

    A review on design of upper limb exoskeletons

    Get PDF

    Soft Gloves: A Review on Recent Developments in Actuation, Sensing, Control and Applications

    Get PDF
    Interest in soft gloves, both robotic and haptic, has enormously grown over the past decade, due to their inherent compliance, which makes them particularly suitable for direct interaction with the human hand. Robotic soft gloves have been developed for hand rehabilitation, for ADLs assistance, or sometimes for both. Haptic soft gloves may be applied in virtual reality (VR) applications or to give sensory feedback in combination with prostheses or to control robots. This paper presents an updated review of the state of the art of soft gloves, with a particular focus on actuation, sensing, and control, combined with a detailed analysis of the devices according to their application field. The review is organized on two levels: a prospective review allows the highlighting of the main trends in soft gloves development and applications, and an analytical review performs an in-depth analysis of the technical solutions developed and implemented in the revised scientific research. Additional minor evaluations integrate the analysis, such as a synthetic investigation of the main results in the clinical studies and trials referred in literature which involve soft gloves

    Design Criteria of Soft Exogloves for Hand Rehabilitation- Assistance Tasks

    Get PDF
    This paper establishes design criteria for soft exogloves (SEG) to be used as rehabilitation or assistance devices. This research consists in identifying, selecting, and grouping SEG features based on the analysis of 91 systems that have been proposed during the last decade. Thus, function, mobility, and usability criteria are defined and explicitly discussed to highlight SEG design guidelines. Additionally, this study provides a detailed description of each system that was analysed including application, functional task, palm design, actuation type, assistance mode, degrees of freedom (DOF), target fingers, motions, material, weight, force, pressure (only for fluids), control strategy, and assessment. Such characteristics have been reported according to specific design methodologies and operating principles. Technological trends are contemplated in this contribution with emphasis on SEG design opportunity areas. In this review, suggestions, limitations, and implications are also discussed in order to enhance future SEG developments aimed at stroke survivors or people with hand disabilities

    Non-linear actuators and simulation tools for rehabilitation devices

    Get PDF
    Mención Internacional en el título de doctorRehabilitation robotics is a field of research that investigates the applications of robotics in motor function therapy for recovering the motor control and motor capability. In general, this type of rehabilitation has been found effective in therapy for persons suffering motor disorders, especially due to stroke or spinal cord injuries. This type of devices generally are well tolerated by the patients also being a motivation in rehabilitation therapy. In the last years the rehabilitation robotics has become more popular, capturing the attention at various research centers. They focused on the development more effective devices in rehabilitation therapy, with a higher acceptance factor of patients tacking into account: the financial cost, weight and comfort of the device. Among the rehabilitation devices, an important category is represented by the rehabilitation exoskeletons, which in addition to the human skeletons help to protect and support the external human body. This became more popular between the rehabilitation devices due to the easily adapting with the dynamics of human body, possibility to use them such as wearable devices and low weight and dimensions which permit easy transportation. Nowadays, in the development of any robotic device the simulation tools play an important role due to their capacity to analyse the expected performance of the system designed prior to manufacture. In the development of the rehabilitation devices, the biomechanical software which is capable to simulate the behaviour interaction between the human body and the robotics devices, play an important role. This helps to choose suitable actuators for the rehabilitation device, to evaluate possible mechanical designs, and to analyse the necessary controls algorithms before being tested in real systems. This thesis presents a research proposing an alternative solution for the current systems of actuation on the exoskeletons for robotic rehabilitation. The proposed solution, has a direct impact, improving issues like device weight, noise, fabrication costs, size an patient comfort. In order to reach the desired results, a biomechanical software based on Biomechanics of Bodies (BoB) simulator where the behaviour of the human body and the rehabilitation device with his actuators can be analysed, was developed. In the context of the main objective of this research, a series of actuators have been analysed, including solutions between the non-linear actuation systems. Between these systems, two solutions have been analysed in detail: ultrasonic motors and Shape Memory Alloy material. Due to the force - weight characteristics of each device (in simulation with the human body), the Shape Memory Alloy material was chosen as principal actuator candidate for rehabilitation devices. The proposed control algorithm for the actuators based on Shape Memory Alloy, was tested over various configurations of actuators design and analysed in terms of energy eficiency, cooling deformation and movement. For the bioinspirated movements, such as the muscular group's biceps-triceps, a control algorithm capable to control two Shape Memory Alloy based actuators in antagonistic movement, has been developed. A segmented exoskeleton based on Shape Memory Alloy actuators for the upper limb evaluation and rehabilitation therapy was proposed to demosntrate the eligibility of the actuation system. This is divided in individual rehabilitation devices for the shoulder, elbow and wrist. The results of this research was tested and validated in the real elbow exoskeleton with two degrees of freedom developed during this thesis.Programa Oficial de Doctorado en Ingeniería Eléctrica, Electrónica y AutomáticaPresidente: Eduardo Rocón de Lima.- Secretario: Concepción Alicia Monje Micharet.- Vocal: Martin Stoele

    A Linear Actuator/Spring Steel-Driven Glove for Assisting Individuals with Activities of Daily Living

    Get PDF
    Over three million people in the U.S. suffer from forearm and hand disabilities. This can result from aging, neurological disorders (e.g., stroke), chronic disease (e.g., arthritis), and injuries. Injuries to hands comprise one-third of all work-related injuries worldwide. This can lead to difficulties with activities of daily living (ADL), where one needs to grasp, lift, and release objects in the household. There is a rise in demand for assistive orthoses and gloves that can allow many people to regain their grasping/releasing ability and, thereby, their independence. The main contribution of this thesis is developing an assistive glove with the actuating mechanism comprised of linear actuators and strips of spring steel to enable bidirectional motion of users\u27 fingers during ADL. The target group of people to use this proposed actuation system was chosen to those who had only diminished hand grasping capabilities. There are already many different gloves in the market. Each one uses different methods of actuation and force transmission, as well as different control methods. These gloves were analyzed by looking at their actuation mechanisms, control systems, and the benefits and downfalls of each one. Vigorous testing was conducted to choose the most effective components for the actuating mechanism. Then, an assistive glove was fabricated which included a control system box that could be easily worn on the forearm of the user. Tests were conducted on the glove to test its effectiveness when the user’s hand was completely passive using four to six participants. Motion capture, force, and electromyography (EMG) data were collected and from those, range of finger motion, maximum grasping capabilities, maximum force generation, and muscle activity were analyzed. The glove was shown to actuate the fingers enough to grasp objects with different sizes ranging in diameter from 40mm to 80mm, with maximum possible weight able to be picked up being around 1000g for the larger sizes. The glove could generate 4N-5N to the index and middle fingers and 10N to the thumb. EMG analysis showed that using the glove to pick up heavy objects caused a decrease in muscle activity of up to 80%. From this analysis, it was shown that the glove has potential to assist with ADL and would provide greater independence for those with diminished hand grasping abilities

    A new fiber braided soft bending actuator for singer exoskeleton

    Get PDF
    This thesis presents a design, development and analysis of a novel bending-type pneumatic soft actuator as a drive source for a finger exoskeleton. Soft actuators are gaining momentum in robotic applications due to their simple structure, high compliance, high power-to-weight ratio and low production cost. Smaller and lighter soft actuator that can provide higher power transmission at lower operating air pressure will benefit finger actuation mechanism compared to motorized cable and pulley-driven finger rehabilitation devices. In this study, a soft actuator with new bending method is proposed. It is based on fibre reinforcement of two fibre braided angles of contraction and extension characteristics combined in a single-chamber cylindrical actuator. Another four design parameters identified that affect the bending motion and the actuating force were the air chamber diameter, position of fibre layer reinforcement, fibre reinforcement coverage angle, and silicone rubber materials. Geometrical and material parameters were varied in Finite Element Method (FEM) simulation for design optimization and some parameters were tested experimentally to validate the FEM models. The effects of fibre angles (contraction and extension) on the bending motion and force were analyzed. The optimized actuator can generate bending motion up to 131° bending angle and the end tip of the actuator can make contact with the other base tip at only 240 kPa given input pressure. Both displacement simulation and experimental testing results matched closely. Maximum bending force of 5.42 N was generated at 350 kPa. A wearable finger soft exoskeleton prototype with five optimized bending actuators was tested to drive finger flexion motion of eight healthy subjects with simulated paralysis conditions. The finger soft exoskeleton demonstrated the ability to provide gripping force of 3.61 ± 0.22 N, gained at 200 kPa given air pressure. The device can successfully provide assistance to weak fingers in gripping at least 240 g object. It shows potential in helping people with weakened finger muscle to be more independent in their finger rehabilitation exercise

    Bio-Inspired Soft Artificial Muscles for Robotic and Healthcare Applications

    Full text link
    Soft robotics and soft artificial muscles have emerged as prolific research areas and have gained substantial traction over the last two decades. There is a large paradigm shift of research interests in soft artificial muscles for robotic and medical applications due to their soft, flexible and compliant characteristics compared to rigid actuators. Soft artificial muscles provide safe human-machine interaction, thus promoting their implementation in medical fields such as wearable assistive devices, haptic devices, soft surgical instruments and cardiac compression devices. Depending on the structure and material composition, soft artificial muscles can be controlled with various excitation sources, including electricity, magnetic fields, temperature and pressure. Pressure-driven artificial muscles are among the most popular soft actuators due to their fast response, high exertion force and energy efficiency. Although significant progress has been made, challenges remain for a new type of artificial muscle that is easy to manufacture, flexible, multifunctional and has a high length-to-diameter ratio. Inspired by human muscles, this thesis proposes a soft, scalable, flexible, multifunctional, responsive, and high aspect ratio hydraulic filament artificial muscle (HFAM) for robotic and medical applications. The HFAM consists of a silicone tube inserted inside a coil spring, which expands longitudinally when receiving positive hydraulic pressure. This simple fabrication method enables low-cost and mass production of a wide range of product sizes and materials. This thesis investigates the characteristics of the proposed HFAM and two implementations, as a wearable soft robotic glove to aid in grasping objects, and as a smart surgical suture for perforation closure. Multiple HFAMs are also combined by twisting and braiding techniques to enhance their performance. In addition, smart textiles are created from HFAMs using traditional knitting and weaving techniques for shape-programmable structures, shape-morphing soft robots and smart compression devices for massage therapy. Finally, a proof-of-concept robotic cardiac compression device is developed by arranging HFAMs in a special configuration to assist in heart failure treatment. Overall this fundamental work contributes to the development of soft artificial muscle technologies and paves the way for future comprehensive studies to develop HFAMs for specific medical and robotic requirements
    corecore