302 research outputs found

    The Use of Artificial Intelligence in the Management of Intracranial Aneurysms

    Get PDF
    The use of artificial intelligence (AI) has potential benefits in the management of intracranial aneurysms. Early detection of intracranial aneurysms is critical due to their high risk of complications such as rupture, vasospasm, and ischemia with highly impact on morbidity and mortality. The main findings suggest that AI can improve the accuracy of aneurysm detection, rupture risk prediction, and assist neurointervention in planning and performing procedures. This chapter discusses the potential for AI to improve patient care by enabling earlier diagnosis and timely treatment, reducing medical errors, costs, morbidity, and mortality. However, further validation of AI-based applications is necessary in a real-world clinical setting

    A framework for intracranial saccular aneurysm detection and quantification using morphological analysis of cerebral angiograms

    Get PDF
    Reliable early prediction of aneurysm rupture can greatly help neurosurgeons to treat aneurysms at the right time, thus saving lives as well as providing significant cost reduction. Most of the research efforts in this respect involve statistical analysis of collected data or simulation of hemodynamic factors to predict the risk of aneurysmal rupture. Whereas, morphological analysis of cerebral angiogram images for locating and estimating unruptured aneurysms is rarely considered. Since digital subtraction angiography (DSA) is regarded as a standard test by the American Stroke Association and American College of Radiology for identification of aneurysm, this paper aims to perform morphological analysis of DSA to accurately detect saccular aneurysms, precisely determine their sizes, and estimate the probability of their ruptures. The proposed diagnostic framework, intracranial saccular aneurysm detection and quantification, first extracts cerebrovascular structures by denoising angiogram images and delineates regions of interest (ROIs) by using watershed segmentation and distance transformation. Then, it identifies saccular aneurysms among segmented ROIs using multilayer perceptron neural network trained upon robust Haralick texture features, and finally quantifies aneurysm rupture by geometrical analysis of identified aneurysmic ROI. De-identified data set of 59 angiograms is used to evaluate the performance of algorithms for aneurysm detection and risk of rupture quantification. The proposed framework achieves high accuracy of 98% and 86% for aneurysm classification and quantification, respectively

    A novel computer-aided diagnosis system for the early detection of hypertension based on cerebrovascular alterations

    Get PDF
    © 2019 The Authors Hypertension is a leading cause of mortality in the USA. While simple tools such as the sphygmomanometer are widely used to diagnose hypertension, they could not predict the disease before its onset. Clinical studies suggest that alterations in the structure of human brains’ cerebrovasculature start to develop years before the onset of hypertension. In this research, we present a novel computer-aided diagnosis (CAD) system for the early detection of hypertension. The proposed CAD system analyzes magnetic resonance angiography (MRA) data of human brains to detect and track the cerebral vascular alterations and this is achieved using the following steps: i) MRA data are preprocessed to eliminate noise effects, correct the bias field effect, reduce the contrast inhomogeneity using the generalized Gauss-Markov random field (GGMRF) model, and normalize the MRA data, ii) the cerebral vascular tree of each MRA volume is segmented using a 3-D convolutional neural network (3D-CNN), iii) cerebral features in terms of diameters and tortuosity of blood vessels are estimated and used to construct feature vectors, iv) feature vectors are then used to train and test various artificial neural networks to classify data into two classes; normal and hypertensive. A balanced data set of 66 subjects were used to test the CAD system. Experimental results reported a classification accuracy of 90.9% which supports the efficacy of the CAD system components to accurately model and discriminate between normal and hypertensive subjects. Clinicians would benefit from the proposed CAD system to detect and track cerebral vascular alterations over time for people with high potential of developing hypertension and to prepare appropriate treatment plans to mitigate adverse events

    Automated Segmentation of Cerebral Aneurysm Using a Novel Statistical Multiresolution Approach

    Get PDF
    Cerebral Aneurysm (CA) is a vascular disease that threatens the lives of many adults. It a ects almost 1:5 - 5% of the general population. Sub- Arachnoid Hemorrhage (SAH), resulted by a ruptured CA, has high rates of morbidity and mortality. Therefore, radiologists aim to detect it and diagnose it at an early stage, by analyzing the medical images, to prevent or reduce its damages. The analysis process is traditionally done manually. However, with the emerging of the technology, Computer-Aided Diagnosis (CAD) algorithms are adopted in the clinics to overcome the traditional process disadvantages, as the dependency of the radiologist's experience, the inter and intra observation variability, the increase in the probability of error which increases consequently with the growing number of medical images to be analyzed, and the artifacts added by the medical images' acquisition methods (i.e., MRA, CTA, PET, RA, etc.) which impedes the radiologist' s work. Due to the aforementioned reasons, many research works propose di erent segmentation approaches to automate the analysis process of detecting a CA using complementary segmentation techniques; but due to the challenging task of developing a robust reproducible reliable algorithm to detect CA regardless of its shape, size, and location from a variety of the acquisition methods, a diversity of proposed and developed approaches exist which still su er from some limitations. This thesis aims to contribute in this research area by adopting two promising techniques based on the multiresolution and statistical approaches in the Two-Dimensional (2D) domain. The rst technique is the Contourlet Transform (CT), which empowers the segmentation by extracting features not apparent in the normal image scale. While the second technique is the Hidden Markov Random Field model with Expectation Maximization (HMRF-EM), which segments the image based on the relationship of the neighboring pixels in the contourlet domain. The developed algorithm reveals promising results on the four tested Three- Dimensional Rotational Angiography (3D RA) datasets, where an objective and a subjective evaluation are carried out. For the objective evaluation, six performance metrics are adopted which are: accuracy, Dice Similarity Index (DSI), False Positive Ratio (FPR), False Negative Ratio (FNR), speci city, and sensitivity. As for the subjective evaluation, one expert and four observers with some medical background are involved to assess the segmentation visually. Both evaluations compare the segmented volumes against the ground truth data

    The 5th International Conference on Biomedical Engineering and Biotechnology (ICBEB 2016)

    Get PDF

    Computer simulations in stroke prevention : design tools and strategies towards virtual procedure planning

    Get PDF

    Scientific poster session

    Get PDF
    corecore