160 research outputs found

    A Design-Led, Materials Based Approach to Human Centered Applications Using Modified Dielectric Electroactive Polymer Sensors

    Get PDF
    This paper describes a design-led exploratory scoping study into the potential use of an industry standard dielectric electroactive polymer (DEAP) sensor for applications in assistive healthcare. The focus of this activity was to explore the physical format and integration of soft materials and sensor combinations with properties that afford an opportunity for accurate and unobtrusive real time body mapping and monitoring. The work involved a series of practical investigations into the capacitance changes in the sensor brought on by deformation through different ways of stretching. The dielectric sensors were selected as a direct mapping tool against the body based on the similarity of the stretch qualities of both the sensor and human skin and muscle resulting in a prototype vest for real time breathing monitoring through sensing thoracic movement. This involved modification of the standard sensors and handcrafting bespoke sensors to map critically relevant areas of the thorax

    Dielectric Elastomer Sensors

    Get PDF
    Dielectric elastomers (DEs) represent a class of electroactive polymers (EAPs) that exhibit a significant electromechanical effect, which has made them very attractive over the last several decades for use as soft actuators, sensors and generators. Based on the principle of a plane‐parallel capacitor, dielectric elastomer sensors consist of a flexible and stretchable dielectric polymer sandwiched between two compliant electrodes. With the development of elastic polymers and stretchable conductors, flexible and sensitive dielectric elastomer tactile sensors, similar to human skin, have been used for measuring mechanical deformations, such as pressure, strain, shear and torsion. For high sensitivity and fast response, air gaps and microstructural dielectric layers are employed in pressure sensors or multiaxial force sensors. Multimodal dielectric elastomer sensors have been reported that can detect mechanical deformation but can also sense temperature, humidity, as well as chemical and biological stimulation in human‐activity monitoring and personal healthcare. Hence, dielectric elastomer sensors have great potential for applications in soft robotics, wearable devices, medical diagnostic and structural health monitoring, because of their large deformation, low cost, ease of fabrication and ease of integration into monitored structures

    Fluidic Fabric Muscle Sheets for Wearable and Soft Robotics

    Full text link
    Conformable robotic systems are attractive for applications in which they can be used to actuate structures with large surface areas, to provide forces through wearable garments, or to realize autonomous robotic systems. We present a new family of soft actuators that we refer to as Fluidic Fabric Muscle Sheets (FFMS). They are composite fabric structures that integrate fluidic transmissions based on arrays of elastic tubes. These sheet-like actuators can strain, squeeze, bend, and conform to hard or soft objects of arbitrary shapes or sizes, including the human body. We show how to design and fabricate FFMS actuators via facile apparel engineering methods, including computerized sewing techniques. Together, these determine the distributions of stresses and strains that can be generated by the FFMS. We present a simple mathematical model that proves effective for predicting their performance. FFMS can operate at frequencies of 5 Hertz or more, achieve engineering strains exceeding 100%, and exert forces greater than 115 times their own weight. They can be safely used in intimate contact with the human body even when delivering stresses exceeding 106^\text{6} Pascals. We demonstrate their versatility for actuating a variety of bodies or structures, and in configurations that perform multi-axis actuation, including bending and shape change. As we also show, FFMS can be used to exert forces on body tissues for wearable and biomedical applications. We demonstrate several potential use cases, including a miniature steerable robot, a glove for grasp assistance, garments for applying compression to the extremities, and devices for actuating small body regions or tissues via localized skin stretch.Comment: 32 pages, 10 figure

    Design and fabrication of flexible tactile sensing and feedback interface for communication by deafblind people

    Get PDF
    Humans generally interact and communicate using five basic sensory modalities and mainly through vision, touch and audio. However, this does not work for deafblind people as they have both impaired hearing and vision modalities, and hence rely on touch-sensing. This necessitates the development of alternative means that allows them to independently interact and communicate. To do this requires a solution which has the capability for tactile sensing and feedback. Therefore, tactile interface becomes a critical component of any assistive device usable by deafblind people for interaction and communication. Given that existing solutions mainly use rigid and commercial components, there is a need to tap into the advancements in flexible electronics in order develop more effective and conformable solutions. This research involves the development of flexible tactile communication interface usable in assistive communication devices for deafblind people. First, commercial sensors and actuators were utilised as a proof-of-concept and then four novel tactile interfaces were explored which include two similar touch-sensitive electromagnetic actuators, one capacitive tactile sensing array, and a facile flexible inductance-based pressure sensor. The two fabricated touch-sensitive electromagnetic actuators (Type 1 and 2) are both based on electromagnetic principle and capable of simultaneous tactile sensing and feedback. Each comprises of a tandem combination of two main modules - the touch-sensing and the actuation module, with both modules integrated as a single device in each case. The actuation module employs a flexible planar spiral coil and a Neodymium magnet assembled in a soft Polydimethylsiloxane (PDMS) structure, while the touch-sensing module is a planar capacitive metal- insulator-metal structure of copper. The flexible coil (~17”m thick and with 45 turns) was fabricated on a Polyimide sheet using Lithographie Galvanoformung Abformung (LIGA) process. The results of characterisation of these actuators at frequencies ranging from 10Hz to 200Hz, shows a maximum displacement (~ 190”m) around 40Hz. Evaluation of this by 40 (20 deafblind and 20 sighted and hearing) participants show that they can feel vibration at this range. Another tactile interface fabricated is an 8 x 8 capacitive tactile sensing array. The sensor was developed on a flexible Polyvinyl Chloride (PVC) sheet with column electrodes deposited on one side and row electrodes on the reverse side. It is intended for use as an assistive tactile communication interface for deafblind people who communicate using deafblind manual alphabets as well as the English block letters. An inductance-based pressure sensor was also designed, fabricated and characterised for use as an input interface for finger Braille as well as other tactile communication methods for deafblind people. It was realised with a soft ferromagnetic elastomer and a 17”m-thick coil fabricated on a flexible 50 ”m-thick polyimide sheet. The ferromagnetic elastomer acts as the core of the coil, which when pressed, sees the metal particles moving closer to each other, leading to changes in the inductance. The coil, with 75”m conductor and 25”m pitch, was also realised using LIGA micromolding technique. Seven different sensors were fabricated using different ratios (1:1, 1:2, 1:3, 1:5, 2:1, 3:1, and 5:1) of Ecoflex to Iron particles. The performance of each sensor was investigated and generally, sensors with higher Iron particles gave better sensitivity, linear as well as dynamic range. In comparison with all other fabricated sensors, the sensor made with 1:5DD was recommended for application as a tactile interface

    The-state-of-the-art of soft robotics to assist mobility: a review of physiotherapist and patient identified limitations of current lower-limb exoskeletons and the potential soft-robotic solutions

    Get PDF
    Background: Soft, wearable, powered exoskeletons are novel devices that may assist rehabilitation, allowing users to walk further or carry out activities of daily living. However, soft robotic exoskeletons, and the more commonly used rigid exoskeletons, are not widely adopted clinically. The available evidence highlights a disconnect between the needs of exoskeleton users and the engineers designing devices. This review aimed to explore the literature on physiotherapist and patient perspectives of the longer-standing, and therefore greater evidenced, rigid exoskeleton limitations. It then offered potential solutions to these limitations, including soft robotics, from an engineering standpoint. Methods: A state-of-the-art review was carried out which included both qualitative and quantitative research papers regarding patient and/or physiotherapist perspectives of rigid exoskeletons. Papers were themed and themes formed the review’s framework. Results: Six main themes regarding the limitations of soft exoskeletons were important to physiotherapists and patients: safety; a one-size-fits approach; ease of device use; weight and placement of device; cost of device; and, specific to patients only, appearance of the device. Potential soft-robotics solutions to address these limitations were offered, including compliant actuators, sensors, suit attachments fitting to user’s body, and the use of control algorithms. Conclusions: It is evident that current exoskeletons are not meeting the needs of their users. Solutions to the limitations offered may inform device development. However, the solutions are not infallible and thus further research and development is required

    Comparison of DC Motors and Dielectric Elastomer Actuators For Wearable Wrist Exoskeletons

    Get PDF
    Paralysis or loss of strength resulting from stroke requires patients to undergo extensive rehabilitation therapy. It is known that intensive therapy contributes significantly to recovery, but as the number of surviving stroke patients increases, it is difficult for clinics to provide patients with the optimal level of therapy. Robotic devices for wrist rehabilitation have been developed to lessen these problems, but at the moment they are physically large and must be used within a clinical setting. More benefit could be obtained if the devices were portable, so that they could be used by the patients on a daily basis. To reduce the size of these devices, other means of actuation need to be considered, as currently DC motors and the required transmission are too large and heavy. Dielectric elastomer actuators (DEAs) may provide a solution to the actuation problem. The focus of this thesis was to compare DC motors with DEAs for use in a wearable wrist exoskeleton to assist with stroke rehabilitation. A simple setup of the forearm, wrist, and hand was developed for testing DC motors and DEAs. For testing the DC motors, kinematic and dynamic models of the arm were created to develop an inverse dynamics controller used to control the movement of the hand. DEAs were fabricated and tested to determine their capabilities in terms of force and range of motion. Based on the data collected, an electromechanical model was optimized to characterize the behavior of the DEAs. The results show that a single DEA strip is not capable of providing the force or range of motion required for a wearable wrist exoskeleton. Future work can be done to improve DEA design so that they may actuate a wearable wrist exoskeleton or could also be considered for use in other wearable rehabilitation devices

    A Review of Cooperative Actuator and Sensor Systems Based on Dielectric Elastomer Transducers

    Get PDF
    This paper presents an overview of cooperative actuator and sensor systems based on dielectric elastomer (DE) transducers. A DE consists of a flexible capacitor made of a thin layer of soft dielectric material (e.g., acrylic, silicone) surrounded with a compliant electrode, which is able to work as an actuator or as a sensor. Features such as large deformation, high compliance, flexibility, energy efficiency, lightweight, self-sensing, and low cost make DE technology particularly attractive for the realization of mechatronic systems that are capable of performance not achievable with alternative technologies. If several DEs are arranged in an array-like configuration, new concepts of cooperative actuator/sensor systems can be enabled, in which novel applications and features are made possible by the synergistic operations among nearby elements. The goal of this paper is to review recent advances in the area of cooperative DE systems technology. After summarizing the basic operating principle of DE transducers, several applications of cooperative DE actuators and sensors from the recent literature are discussed, ranging from haptic interfaces and bio-inspired robots to micro-scale devices and tactile sensors. Finally, challenges and perspectives for the future development of cooperative DE systems are discussed

    Wearable exoskeleton systems based-on pneumatic soft actuators and controlled by parallel processing

    Get PDF
    Human assistance innovation is essential in an increasingly aging society and one technology that may be applicable is exoskeletons. However, traditional rigid exoskeletons have many drawbacks. This research includes the design and implementation of upper-limb power assist and rehabilitation exoskeletons based on pneumatic soft actuators. A novel extensor-contractor pneumatic muscle has been designed and constructed. This new actuator has bidirectional action, allowing it to both extend and contract, as well as create force in both directions. A mathematical model has been developed for the new novel actuator which depicts the output force of the actuator. Another new design has been used to create a novel bending pneumatic muscle, based on an extending McKibben muscle and modelled mathematically according to its geometric parameters. This novel bending muscle design has been used to create two versions of power augmentation gloves. These exoskeletons are controlled by adaptive controllers using human intention. For finger rehabilitation a glove has been developed to bend the fingers (full bending) by using our novel bending muscles. Inspired by the zero position (straight fingers) problem for post-stroke patients, a new controllable stiffness bending actuator has been developed with a novel prototype. To control this new rehabilitation exoskeleton, online and offline controller systems have been designed for the hand exoskeleton and the results have been assessed experimentally. Another new design of variable stiffness actuator, which controls the bending segment, has been developed to create a new version of hand exoskeletons in order to achieve more rehabilitation movements in the same single glove. For Forearm rehabilitation, a rehabilitation exoskeleton has been developed for pronation and supination movements by using the novel extensor-contractor pneumatic muscle. For the Elbow rehabilitation an elbow rehabilitation exoskeleton was designed which relies on novel two-directional bending actuators with online and offline feedback controllers. Lastly for upper-limb joint is the wrist, we designed a novel all-directional bending actuator by using the moulding bladder to develop the wrist rehabilitation exoskeleton by a single all-directional bending muscle. Finally, a totally portable, power assistive and rehabilitative prototype has been developed using a parallel processing intelligent control chip
    • 

    corecore