3,904 research outputs found

    UHF diagnostic monitoring techniques for power transformers

    Get PDF
    This paper initially gives an introduction to ultra-high frequency (UHF) partial discharge monitoring techniques and their application to gas insulated substations. Recent advances in the technique, covering its application to power transformers, are then discussed and illustrated by means of four site trials. Mounting and installation of the UHF sensors is described and measurements of electrical discharges inside transformers are presented in a range of formats, demonstrating the potential of the UHF method. A procedure for locating sources of electrical discharge is described and demonstrated by means of a practical example where a source of sparking on a tap changer lead was located to within 15 cm. Progress with the development of a prototype on-line monitoring and diagnostic system is reviewed and possible approaches to its utilization are discussed. New concepts for enhancing the capabilities of the UHF technique are presented, including the possibility of monitoring the internal mechanical integrity of plant. The research presented provides sufficient evidence to justify the installation of robust UHF sensors on transformer tanks to facilitate their monitoring if and when required during the service lifetime

    Development of the future generation of smart high voltage connectors and related components for substations, with energy autonomy and wireless data transmission capability

    Get PDF
    The increased dependency on electricity of modern society, makes reliability of power transmission systems a key point. This goal can be achieved by continuously monitoring power grid parameters, so possible failure modes can be predicted beforehand. It can be done using existing Information and Communication Technologies (ICT) and Internet of Things (10T) technologies that include instrumentation and wireless communication systems, thus forming a wireless sensor network (WSN). Electrical connectors are among the most critical parts of any electrical system and hence, they can act as nodes of such WSN. Therefore, the fundamental objective of this thesis is the design, development and experimental validation of a self-powered IOT solution for real-time monitoring of the health status of a high-voltage substation connector and related components of the electrical substation. This new family of power connectors is called SmartConnector and incorporates a thermal energy harvesting system powering a microcontroller that controls a transmitter and several electronic sensors to measure the temperature, current and the electrical contact resistance (ECR) of the connector. These measurements are sent remotely via a Bluetooth 5 wireless communication module to a local gateway, which further transfers the measured data to a database server for storage as well as further analysis and visualization. By this way, after suitable data processing, the health status of the connector can be available in real-time, allowing different appealing functions, such as assessing the correct installation of the connector, the current health status or its remaining useful life (RUL) in real-time. The same principal can also be used for other components of substation like spacers, insulators, conductors, etc. Hence, to prove universality of this novel approach, a similar strategy is applied to a spacer which is capable of measuring uneven current distribution in three closely placed conductors. This novel IOT device is called as SmartSpacer. Care has to be taken that this technical and scientific development has to be compatible with existing substation bus bars and conductors, and especially to be compatible with the high operating voltages, i.e., from tens to hundreds of kilo-Volts (kV), and with currents in the order of some kilo-pm peres (kA). Although some electrical utilities and manufacturers have progressed in the development of such technologies, including smart meters and smart sensors, electrical device manufacturers such as of substation connectors manufacturers have not yet undertaken the technological advancement required for the development of such a new family of smart components involved in power transmission, which are designed to meet the future needs.La mayor dependencia de la electricidad de la sociedad moderna hace que la fiabilidad de los sistemas de transmisión de energía sea un punto clave. Este objetivo se puede lograr mediante la supervisión continua de los parámetros de la red eléctrica, por lo que los posibles modos de fallo se pueden predecir de antemano. Se puede hacer utilizando las tecnologías existentes de Tecnologías de la Información y la Comunicación (1CT) e Internet de las cosas (lo T) que incluyen sistemas de instrumentación y comunicación inalámbrica, formando así una red de sensores inalámbricos (WSN). Los conectores eléctricos se encuentran entre las partes más críticas de cualquier sistema eléctrico y, por lo tanto, pueden actuar como nodos de dicho VVSN. Por lo tanto, el objetivo fundamental de esta tesis es el diseño, desarrollo y validación experimental de una solución IOT autoalimentada para la supervisión en tiempo real del estado de salud de un conector de subestación de alta tensión y componentes relacionados de la subestación eléctrica. Esta nueva familia de conectores de alimentación se llama SmartConnector e incorpora un sistema de recolección de energía térmica que alimenta un microcontrolador que controla un transmisor y varios sensores electrónicos para medir la temperatura, la corriente y la resistencia del contacto eléctrico (ECR) del conector. Esta nueva familia de conectores de alimentación se llama SmartConnector e incorpora un sistema de recolección de energía térmica que alimenta un microcontrolador que controla un transmisor y varios sensores electrónicos para medir la temperatura, la corriente y la resistencia al contacto eléctrico (ECR) del conector. De esta manera, después del procesamiento de datos adecuado, el estado de salud del conector puede estar disponible en tiempo real, permitiendo diferentes funciones atractivas, como evaluar la correcta instalación del conector, el estado de salud actual o su vida útil restante (RUL) en tiempo real. El mismo principio también se puede utilizar para otros componentes de la subestación como espaciadores, aislantes, conductores, etc. Por lo tanto, para demostrar la universalidad de este enfoque novedoso, se aplica una estrategia similar a un espaciador, que es capaz de medir la distribución de corriente desigual en tres conductores estrechamente situados. Hay que tener cuidado de que este desarrollo técnico y científico tenga que sea compatible con las barras y "busbars" de subestación existentes, y sobre todo para ser compatible con las altas tensiones de funcionamiento, es decir, de decenas a cientos de kilovoltios (kV), y con corrientes en el orden de algunos kilo-Amperes (kA). Aunque algunas empresas eléctricas y fabricantes han progresado en el desarrollo de este tipo de tecnologías, incluidos medidores inteligentes y sensores inteligentes, los fabricantes de dispositivos eléctricos, como los fabricantes de conectores de subestación, aún no han emprendido el avance tecnológico necesario para el desarrollo de una nueva familia de componentes intel

    Experimental study of visual corona under aeronautic pressure conditions using low-cost imaging sensors

    Get PDF
    Visual corona tests have been broadly applied for identifying the critical corona points of diverse high-voltage devices, although other approaches based on partial discharge or radio interference voltage measurements are also widely applied to detect corona activity. Nevertheless, these two techniques must be applied in screened laboratories, which are scarce and expensive, require sophisticated instrumentation, and typically do not allow location of the discharge points. This paper describes the detection of the visual corona and location of the critical corona points of a sphere-plane gap configurations under different pressure conditions ranging from 100 to 20 kPa, covering the pressures typically found in aeronautic environments. The corona detection is made with a low-cost CMOS imaging sensor from both the visible and ultraviolet (UV) spectrum, which allows detection of the discharge points and their locations, thus significantly reducing the complexity and costs of the instrumentation required while preserving the sensitivity and accuracy of the measurements. The approach proposed in this paper can be applied in aerospace applications to prevent the arc tracking phenomenon, which can lead to catastrophic consequences since there is not a clear protection solution, due to the low levels of leakage current involved in the pre-arc phenomenon.Peer ReviewedPostprint (published version

    Time domain analysis of switching transient fields in high voltage substations

    Get PDF
    Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within the substations. The radiated fields may interfere and disrupt normal operations of electronic equipment used within the substation for measurement, control and communication purposes. Hence there is the need to fully characterise the substation electromagnetic environment as early as the design stage of substation planning and operation to ensure safe operations of the electronic equipment. This paper deals with the computation of transient electromagnetic fields due to switching within a high voltage air-insulated substation (AIS) using the finite difference time domain (FDTD) metho

    Power system applications of fiber optics

    Get PDF
    Power system applications of optical systems, primarily using fiber optics, are reviewed. The first section reviews fibers as components of communication systems. The second section deals with fiber sensors for power systems, reviewing the many ways light sources and fibers can be combined to make measurements. Methods of measuring electric field gradient are discussed. Optical data processing is the subject of the third section, which begins by reviewing some widely different examples and concludes by outlining some potential applications in power systems: fault location in transformers, optical switching for light fired thyristors and fault detection based on the inherent symmetry of most power apparatus. The fourth and final section is concerned with using optical fibers to transmit power to electric equipment in a high voltage situation, potentially replacing expensive high voltage low power transformers. JPL has designed small photodiodes specifically for this purpose, and fabricated and tested several samples. This work is described

    Arc tracking control in insulation systems for aeronautic applications: challenges, opportunities, and research needs

    Get PDF
    Next generation aircrafts will use more electrical power to reduce weight, fuel consumption, system complexity and greenhouse gas emissions. However, new failure modes and challenges arise related to the required voltage increase and consequent rise of electrical stress on wiring insulation materials, thus increasing the risk of electrical arc appearance. This work performs a critical and comprehensive review concerning arc tracking effects in wiring insulation systems, underlying mechanisms, role of materials and possible mitigation strategies, with a special focus on aircraft applications. To this end an evaluation of the scientific and technological state of the art is carried out from the analysis of theses, research articles, technical reports, international standards and white papers. This review paper also reports the limitations of existing insulation materials, standard test methods and mitigation approaches, while identifying the research needs to comply with the future demands of the aircraft industryPeer ReviewedPostprint (published version

    Aerometry instrumentation study Final report

    Get PDF
    Techniques and instruments for meteorological measurements in Mars and Venus atmosphere

    Energy harvesting methods for transmission lines: a comprehensive review

    Get PDF
    Humanity faces important challenges concerning the optimal use, security, and availability of energy systems, particularly electrical power systems and transmission lines. In this context, data-driven predictive maintenance plans make it possible to increase the safety, stability, reliability, and availability of electrical power systems. In contrast, strategies such as dynamic line rating (DLR) make it possible to optimize the use of power lines. However, these approaches require developing monitoring plans based on acquiring electrical data in real-time using different types of wireless sensors placed in strategic locations. Due to the specific conditions of the transmission lines, e.g., high electric and magnetic fields, this a challenging problem, aggravated by the harsh outdoor environments where power lines are built. Such sensors must also incorporate an energy harvesting (EH) unit that supplies the necessary electronics. Therefore, the EH unit plays a key role, so when designing such electronic systems, care must be taken to select the most suitable EH technology, which is currently evolving rapidly. This work reviews and analyzes the state-of-the-art technology for EH focused on transmission lines, as it is an area with enormous potential for expansion. In addition to recent advances, it also discusses the research needs and challenges that need to be addressed. Despite the importance of this topic, there is still much to investigate, as this area is still in its infancy. Although EH systems for transmission lines are reviewed, many other applications could potentially benefit from introducing wireless sensors with EH capabilities, such as power transformers, distribution switches, or low- and medium-voltage power lines, among others.This research was funded by Ministerio de Ciencia e Innovación de España, grant number PID2020-114240RB-I00 and by the Generalitat de Catalunya, grant number 2017 SGR 967.Peer ReviewedPostprint (author's final draft

    Partial Discharge Testing and Detection under PWM Voltage

    Get PDF
    Partial Discharge detection and measurement is an important part of electric insulation design. However, in PWM (pulse width modulation) voltage source converter environments, the noise resulting from switching voltage (rise and fall times of tens of nanoseconds) makes detection and extraction of partial discharge difficult. Unique methods of partial discharge detection are needed to address and decouple the noise from partial discharge measurements. PWM voltage can feature high switching speeds and high dv/dt during voltage switching. These PWM voltage behaviors are not found in traditional utility high voltage applications, and the effects that this type of voltage has on insulation and associated partial discharge behavior are not well understood. A good understanding of partial discharge behavior is vital to effective insulation design in high voltage power electronic systems. \\ To better understand the behavior of partial discharge in a PWM voltage source environment, a partial discharge testing platform is designed. This testing platform features a 3kV Si half-bridge converter to apply PWM voltage at varying switching frequency (5-60kHz) and dv/dt (11-16V/ns). An additional full-bridge 10kV SiC converter provides extra voltage capability for partial discharge testing. Converters with wide bandgap semiconductors can feature high switching frequency and dv/dt not currently possible with Si converters. The effect that switching frequency and dv/dt has on partial discharge behavior will become more of an issue as wide bandgap semiconductors are operated at full potential. The output voltage from this converter will be applied to test subjects chosen to model types of partial discharge: surface, internal, and corona discharge. This testing platform requires an effective method of partial discharge detection that is not interfered by voltage switching transient noise. Three electrically isolated methods of detection are explored to determine the most effective methods of partial discharge detection in the presence of PWM voltage switching transient noise: optical detection, electromagnetic detection, and acoustic detection. Post-processing wavelet denoising techniques are applied to remove any remaining noise from partial discharge signals. With effective partial discharge detection and a testing platform with test subjects chosen to model types of discharge, the effects of PWM voltage on partial discharge behavior are demonstrated. Methods of partial discharge classification and identification are demonstrated as well to show methods to effectively identify defects in insulation caused by partial discharge due to PWM voltage
    corecore