402 research outputs found

    Three Dimensional Bistatic Tomography Using HDTV

    Get PDF
    The thesis begins with a review of the principles of diffraction and reflection tomography; starting with the analytic solution to the inhomogeneous Helmholtz equation, after linearization by the Born approximation (the weak scatterer solution), and arriving at the Filtered Back Projection (Propagation) method of reconstruction. This is followed by a heuristic derivation more directly couched in the radar imaging context, without the rigor of the general inverse problem solution and more closely resembling an imaging turntable or inverse synthetic aperture radar. The heuristic derivation leads into the concept of the line integral and projections (the Radon Transform), followed by more general geometries where the plane wave approximation is invalid. We proceed next to study of the dependency of reconstruction on the space-frequency trajectory, combining the spatial aperture and waveform. Two and three dimensional apertures, monostatic and bistatic, fully and sparsely sampled and including partial apertures, with controlled waveforms (CW and pulsed, with and without modulation) define the filling of k-space and concomitant reconstruction performance. Theoretical developments in the first half of the thesis are applied to the specific example of bistatic tomographic imaging using High Definition Television (HDTV); the United States version of DVB-T. Modeling of the HDTV waveform using pseudonoise modulation to represent the hybrid 8VSB HDTV scheme and the move-stop-move approximation established the imaging potential, employing an idealized, isotropic 18 scatterer. As the move-stop-move approximation places a limitation on integration time (in cross correlation/pulse compression) due to transmitter/receiver motion, an exact solution for compensation of Doppler distortion is derived. The concept is tested with the assembly and flight test of a bistatic radar system employing software-defined radios (SDR). A three dimensional, bistatic collection aperture, exploiting an elevated commercial HDTV transmitter, is focused to demonstrate the principle. This work, to the best of our knowledge, represents a first in the formation of three dimensional images using bistatically-exploited television transmitters

    Modeling the Anisotropic Resolution and Noise Properties of Digital Breast Tomosynthesis

    Get PDF
    Digital breast tomosynthesis (DBT) is a 3D imaging modality in which a reconstruction of the breast is generated from various x-ray projections. Due to the newness of this technology, the development of an analytical model of image quality has been on-going. In this thesis, a more complete model is developed by addressing the limitations found in the previous linear systems (LS) model [Zhao, Med. Phys. 2008, 35(12): 5219-32]. A central assumption of the LS model is that the angle of x-ray incidence is approximately normal to the detector in each projection. To model the effect of oblique x-ray incidence, this thesis generalizes Swank\u27s calculations of the transfer functions of x-ray fluorescent screens to arbitrary incident angles. In the LS model, it is also assumed that the pixelation in the reconstruction grid is the same as the detector; hence, the highest frequency that can be resolved is the detector alias frequency. This thesis considers reconstruction grids with smaller pixelation to investigate super-resolution, or visibility of higher frequencies. A sine plate is introduced as a conceptual test object to analyze super-resolution. By orienting the long axis of the sine plate at various angles, the feasibility of oblique reconstruction planes is also investigated. This formulation differs from the LS model in which reconstruction planes are parallel to the breast support. It is shown that the transfer functions for arbitrary angles of x-ray incidence can be modeled in closed form. The high frequency modulation transfer function (MTF) and detective quantum efficiency (DQE) are degraded due to oblique x-ray incidence. In addition, using the sine plate, it is demonstrated that a reconstruction can resolve frequencies exceeding the detector alias frequency. Experimental images of bar patterns verified the existence of super-resolution. Anecdotal clinical examples showed that super-resolution improves the visibility of microcalcifications. The feasibility of oblique reconstructions was established theoretically with the sine plate and was validated experimentally with bar patterns. This thesis develops a more complete model of image quality in DBT by addressing the limitations of the LS model. In future studies, this model can be used as a tool for optimizing DBT

    Wave tomography

    Get PDF

    Object recognition using multi-view imaging

    No full text
    Single view imaging data has been used in most previous research in computer vision and image understanding and lots of techniques have been developed. Recently with the fast development and dropping cost of multiple cameras, it has become possible to have many more views to achieve image processing tasks. This thesis will consider how to use the obtained multiple images in the application of target object recognition. In this context, we present two algorithms for object recognition based on scale- invariant feature points. The first is single view object recognition method (SOR), which operates on single images and uses a chirality constraint to reduce the recognition errors that arise when only a small number of feature points are matched. The procedure is extended in the second multi-view object recognition algorithm (MOR) which operates on a multi-view image sequence and, by tracking feature points using a dynamic programming method in the plenoptic domain subject to the epipolar constraint, is able to fuse feature point matches from all the available images, resulting in more robust recognition. We evaluated these algorithms using a number of data sets of real images capturing both indoor and outdoor scenes. We demonstrate that MOR is better than SOR particularly for noisy and low resolution images, and it is also able to recognize objects that are partially occluded by combining it with some segmentation techniques

    The quantitative analysis of transonic flows by holographic interferometry

    Get PDF
    This thesis explores the feasibility of routine transonic flow analysis by holographic interferometry. Holography is potentially an important quantitative flow diagnostic, because whole-field data is acquired non-intrusively without the use of particle seeding. Holographic recording geometries are assessed and an image plane specular illumination configuration is shown to reduce speckle noise and maximise the depth-of-field of the reconstructed images. Initially, a NACA 0012 aerofoil is wind tunnel tested to investigate the analysis of two-dimensional flows. A method is developed for extracting whole-field density data from the reconstructed interferograms. Fringe analysis errors axe quantified using a combination of experimental and computer generated imagery. The results are compared quantitatively with a laminar boundary layer Navier-Stokes computational fluid dynamics (CFD) prediction. Agreement of the data is excellent, except in the separated wake where the experimental boundary layer has undergone turbulent transition. A second wind tunnel test, on a cone-cylinder model, demonstrates the feasibility of recording multi-directional interferometric projections using holographic optical elements (HOE’s). The prototype system is highly compact and combines the versatility of diffractive elements with the efficiency of refractive components. The processed interferograms are compared to an integrated Euler CFD prediction and it is shown that the experimental shock cone is elliptical due to flow confinement. Tomographic reconstruction algorithms are reviewed for analysing density projections of a three-dimensional flow. Algebraic reconstruction methods are studied in greater detail, because they produce accurate results when the data is ill-posed. The performance of these algorithms is assessed using CFD input data and it is shown that a reconstruction accuracy of approximately 1% may be obtained when sixteen projections are recorded over a viewing angle of ±58°. The effect of noise on the data is also quantified and methods are suggested for visualising and reconstructing obstructed flow regions

    Imaging using volume holograms

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.Includes bibliographical references (p. 185-196).Volume holograms can be thought of as self-aligned 3D stacks of diffractive elements that operate coherently on incident fields as they propagate through the structure. In this thesis, we propose, design and implement imaging systems that incorporate a volume hologram as one of the elements that operate on the optical field incident on the imaging system. We show that a volume hologram acts like a "smart" lens that can perform several useful functions in an imaging system and demonstrate the same experimentally. To this end, we first develop the theory of volume holographic imaging and calculate the imaging properties of the field diffracted by a volume hologram for the special cases of coherent and incoherent monochromatic illumination. We concentrate on two simple imaging system configurations, viz. volume holograms recorded using a planar signal and either a spherical or a planar reference beam. We pay particular attention to the depth resolution of each system and discuss how appropriately designed objective optics placed before the volume hologram can enhance the depth resolution. We also derive the imaging properties of the volume holographic "smart" lens under conditions of incoherent broadband illumination. We show that multiple volume holographic sensors can be configured to acquire different perspectives of an object with enhanced resolution. We experimentally verify the developed theories and implement several volume holographic imaging systems for a wide range of imaging applications. We compare volume holographic imaging with some commonly used 3D imaging systems and discuss the merits of each system. We find that volume holograms with low diffraction efficiencies result in lower photon counts(cont.) and information loss and hence poorer imaging performance. We present an optical method to solve this problem by resonating the volume hologram inside an optical cavity. Finally, we conclude with some directions for future work in this emerging field.by Arnab Sinha.Ph.D
    corecore