9,027 research outputs found
Generating Diffusion MRI scalar maps from T1 weighted images using generative adversarial networks
Diffusion magnetic resonance imaging (diffusion MRI) is a non-invasive
microstructure assessment technique. Scalar measures, such as FA (fractional
anisotropy) and MD (mean diffusivity), quantifying micro-structural tissue
properties can be obtained using diffusion models and data processing
pipelines. However, it is costly and time consuming to collect high quality
diffusion data. Here, we therefore demonstrate how Generative Adversarial
Networks (GANs) can be used to generate synthetic diffusion scalar measures
from structural T1-weighted images in a single optimized step. Specifically, we
train the popular CycleGAN model to learn to map a T1 image to FA or MD, and
vice versa. As an application, we show that synthetic FA images can be used as
a target for non-linear registration, to correct for geometric distortions
common in diffusion MRI
Automatic Spatial Calibration of Ultra-Low-Field MRI for High-Accuracy Hybrid MEG--MRI
With a hybrid MEG--MRI device that uses the same sensors for both modalities,
the co-registration of MRI and MEG data can be replaced by an automatic
calibration step. Based on the highly accurate signal model of ultra-low-field
(ULF) MRI, we introduce a calibration method that eliminates the error sources
of traditional co-registration. The signal model includes complex sensitivity
profiles of the superconducting pickup coils. In ULF MRI, the profiles are
independent of the sample and therefore well-defined. In the most basic form,
the spatial information of the profiles, captured in parallel ULF-MR
acquisitions, is used to find the exact coordinate transformation required. We
assessed our calibration method by simulations assuming a helmet-shaped
pickup-coil-array geometry. Using a carefully constructed objective function
and sufficient approximations, even with low-SNR images, sub-voxel and
sub-millimeter calibration accuracy was achieved. After the calibration,
distortion-free MRI and high spatial accuracy for MEG source localization can
be achieved. For an accurate sensor-array geometry, the co-registration and
associated errors are eliminated, and the positional error can be reduced to a
negligible level.Comment: 11 pages, 8 figures. This work is part of the BREAKBEN project and
has received funding from the European Union's Horizon 2020 research and
innovation programme under grant agreement No 68686
Intersubject Regularity in the Intrinsic Shape of Human V1
Previous studies have reported considerable intersubject variability in the three-dimensional geometry of the human primary visual cortex (V1). Here we demonstrate that much of this variability is due to extrinsic geometric features of the cortical folds, and that the intrinsic shape of V1 is similar across individuals. V1 was imaged in ten ex vivo human hemispheres using high-resolution (200 μm) structural magnetic resonance imaging at high field strength (7 T). Manual tracings of the stria of Gennari were used to construct a surface representation, which was computationally flattened into the plane with minimal metric distortion. The instrinsic shape of V1 was determined from the boundary of the planar representation of the stria. An ellipse provided a simple parametric shape model that was a good approximation to the boundary of flattened V1. The aspect ration of the best-fitting ellipse was found to be consistent across subject, with a mean of 1.85 and standard deviation of 0.12. Optimal rigid alignment of size-normalized V1 produced greater overlap than that achieved by previous studies using different registration methods. A shape analysis of published macaque data indicated that the intrinsic shape of macaque V1 is also stereotyped, and similar to the human V1 shape. Previoud measurements of the functional boundary of V1 in human and macaque are in close agreement with these results
A mask-based approach for the geometric calibration of thermal-infrared cameras
Accurate and efficient thermal-infrared (IR) camera calibration is important for advancing computer vision research within the thermal modality. This paper presents an approach for geometrically calibrating individual and multiple cameras in both the thermal and visible modalities. The proposed technique can be used to correct for lens distortion and to simultaneously reference both visible and thermal-IR cameras to a single coordinate frame. The most popular existing approach for the geometric calibration of thermal cameras uses a printed chessboard heated by a flood lamp and is comparatively inaccurate and difficult to execute. Additionally, software toolkits provided for calibration either are unsuitable for this task or require substantial manual intervention. A new geometric mask with high thermal contrast and not requiring a flood lamp is presented as an alternative calibration pattern. Calibration points on the pattern are then accurately located using a clustering-based algorithm which utilizes the maximally stable extremal region detector. This algorithm is integrated into an automatic end-to-end system for calibrating single or multiple cameras. The evaluation shows that using the proposed mask achieves a mean reprojection error up to 78% lower than that using a heated chessboard. The effectiveness of the approach is further demonstrated by using it to calibrate two multiple-camera multiple-modality setups. Source code and binaries for the developed software are provided on the project Web site
Recommended from our members
A new phantom and gradient isocenter estimation for magnetic resonance imaging distortion correction
The purpose of this study was to develop and implement a numerical software based method that can accurately correct the distortion of MR images generated by 3T MRI scanner. To accomplish this, a new phantom has been designed from scratch to capture the distortions inside 3T MRI scanner. An algorithm has been developed, based on the unique geometric feature of the new phantom, to estimate the location of gradient isocenter of the magnetic field inside 3T MRI scanner for the first time
Towards development of automatic path planning system in image-guided neurosurgery
With the advent of advanced computer technology, many computer-aided systems have evolved to assist in medical related work including treatment, diagnosis, and even surgery. In modern neurosurgery, Magnetic Resonance Image guided stereotactic surgery exactly complies with this trend. It is a minimally invasive operation being much safer than the traditional open-skull surgery, and offers higher precision and more effective operating procedures compared to conventional craniotomy. However, such operations still face significant challenges of planning the optimal neurosurgical path in order to reach the ideal position without damage to important internal structures. This research aims to address this major challenge. The work begins with an investigation of the problem of distortion induced by MR images. It then goes on to build a template of the Circle of Wills brain vessels, realized from a collection of Magnetic Resonance Angiography images, which is needed to maintain operating standards when, as in many cases, Magnetic Resonance Angiography images are not available for patients. Demographic data of brain tumours are also studied to obtain further understanding of diseased human brains through the development of an effect classifier. The developed system allows the internal brain structure to be ‘seen’ clearly before the surgery, giving surgeons a clear picture and thereby makes a significant contribution to the eventual development of a fully automatic path planning system
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
- …