3,257 research outputs found

    Total Hip Joint Replacement Biotelemetry System

    Get PDF
    The development of a biotelemetry system that is hermetically sealed within a total hip replacement implant is reported. The telemetry system transmits six channels of stress data to reconstruct the major forces acting on the neck of the prosthesis and uses an induction power coupling technique to eliminate the need for internal batteries. The activities associated with the telemetry microminiaturization, data recovery console, hardware fabrications, power induction systems, electrical and mechanical testing and hermetic sealing test results are discussed

    Secure Mutual Self-Authenticable Mechanism for Wearable Devices

    Get PDF
    YesDue to the limited communication range of wearable devices, there is the need for wearable devices to communicate amongst themselves, supporting devices and the internet or to the internet. Most wearable devices are not internet enabled and most often need an internet enabled broker device or intermediate device in order to reach the internet. For a secure end to end communication between these devices security measures like authentication must be put in place in other to prevent unauthorised access to information given the sensitivity of the information collected and transmitted. Therefore, there are other existing authentication solutions for wearable devices but these solutions actively involve from time to time the user of the device which is prone to a lot of challenges. As a solution to these challenges, this paper proposes a secure point-to-point Self-authentication mechanism that involves device to device interaction. This work exploits existing standards and framework like NFC, PPP, EAP etc. in other to achieve a device compatible secure authentication protocol amongst wearable device and supporting devices.

    A Real-Time Health Monitoring System for Remote Cardiac Patients Using Smartphone and Wearable Sensors

    Get PDF
    Online telemedicine systems are useful due to the possibility of timely and efficient healthcare services. These systems are based on advanced wireless and wearable sensor technologies. The rapid growth in technology has remarkably enhanced the scope of remote health monitoring systems. In this paper, a real-time heart monitoring system is developed considering the cost, ease of application, accuracy, and data security. The system is conceptualized to provide an interface between the doctor and the patients for two-way communication. The main purpose of this study is to facilitate the remote cardiac patients in getting latest healthcare services which might not be possible otherwise due to low doctor-to-patient ratio. The developed monitoring system is then evaluated for 40 individuals (aged between 18 and 66 years) using wearable sensors while holding an Android device (i.e., smartphone under supervision of the experts). The performance analysis shows that the proposed system is reliable and helpful due to high speed. The analyses showed that the proposed system is convenient and reliable and ensures data security at low cost. In addition, the developed system is equipped to generate warning messages to the doctor and patient under critical circumstances

    Distributed Computing and Monitoring Technologies for Older Patients

    Get PDF
    This book summarizes various approaches for the automatic detection of health threats to older patients at home living alone. The text begins by briefly describing those who would most benefit from healthcare supervision. The book then summarizes possible scenarios for monitoring an older patient at home, deriving the common functional requirements for monitoring technology. Next, the work identifies the state of the art of technological monitoring approaches that are practically applicable to geriatric patients. A survey is presented on a range of such interdisciplinary fields as smart homes, telemonitoring, ambient intelligence, ambient assisted living, gerontechnology, and aging-in-place technology. The book discusses relevant experimental studies, highlighting the application of sensor fusion, signal processing and machine learning techniques. Finally, the text discusses future challenges, offering a number of suggestions for further research directions

    Infection prevention and control audit-feedback instrument for oral health care in South Africa

    Get PDF
    Thesis (D. Tech. (Biomedical Technology)) -- Central University of Technology, Free State, 2015This study reviewed national and international literature to develop an audit-feedback instrument (AFI) to monitor adherence of South African oral health care facilities with compliance to infection prevention and control precautions. In a multi-phased literature search, existing infection prevention and control recommendations, guidelines and audit-feedback instruments were reviewed and broadened to include “dental audit tools”, as well as audit tools from other health care disciplines. Audit-feedback instruments were scrutinised for user friendliness, the use of simple language, electronic calculations and feedback possibilities. A new South African AFI was proposed, considering the differences between public and private oral health care facilities and also the diversity of training levels of oral health care personnel employed. Eleven focus areas supporting all aspects of infection prevention and control in oral health care facilities, including administrative controls; personnel protection controls; environmental- and work controls; surface contamination management; equipment maintenance, service or repair; air- and waterline management; personal protective equipment usage; personal and hand hygiene practices; sterilisation practices; safe sharps handling and waste management were included. The AFI was tested in a sample of 50 oral health care facilities. None of the participating facilities demonstrated 100% compliance. Personal- and hand hygiene practices and waste management performed the best, at respectively 75% and 63%, while administrative controls and air- and waterline management scored the lowest mean values; 31% and 36% respectively The general lack of compliance with infection prevention and control precautions in the participating oral health care facilities clearly poses a safety hazard to both patients and oral health care workers. Results indicate that adherence of South African oral health care facilities with compliance to infection prevention and control precautions need to be improved. The AFI should go a long way towards improving safety and the high expectations about providing quality infection prevention and control outcomes in oral health care

    PICT-DPA: A Quality-Compliance Data Processing Architecture to Improve the Performance of Integrated Emergency Care Clinical Decision Support System

    Get PDF
    Emergency Care System (ECS) is a critical component of health care systems by providing acute resuscitation and life-saving care. As a time-sensitive care operation system, any delay and mistake in the decision-making of these EC functions can create additional risks of adverse events and clinical incidents. The Emergency Care Clinical Decision Support System (EC-CDSS) has proven to improve the quality of the aforementioned EC functions. However, the literature is scarce on how to implement and evaluate the EC-CDSS with regard to the improvement of PHOs, which is the ultimate goal of ECS. The reasons are twofold: 1) lack of clear connections between the implementation of EC-CDSS and PHOs because of unknown quality attributes; and 2) lack of clear identification of stakeholders and their decision processes. Both lead to the lack of a data processing architecture for an integrated EC-CDSS that can fulfill all quality attributes while satisfying all stakeholders’ information needs with the goal of improving PHOs. This dissertation identified quality attributes (PICT: Performance of the decision support, Interoperability, Cost, and Timeliness) and stakeholders through a systematic literature review and designed a new data processing architecture of EC-CDSS, called PICT-DPA, through design science research. The PICT-DPA was evaluated by a prototype of integrated PICT-DPA EC-CDSS, called PICTEDS, and a semi-structured user interview. The evaluation results demonstrated that the PICT-DPA is able to improve the quality attributes of EC-CDSS while satisfying stakeholders’ information needs. This dissertation made theoretical contributions to the identification of quality attributes (with related metrics) and stakeholders of EC-CDSS and the PICT Quality Attribute model that explains how EC-CDSSs may improve PHOs through the relationships between each quality attribute and PHOs. This dissertation also made practical contributions on how quality attributes with metrics and variable stakeholders could be able to guide the design, implementation, and evaluation of any EC-CDSS and how the data processing architecture is general enough to guide the design of other decision support systems with requirements of the similar quality attributes

    Adopting Modern Fitness Sensors to Improve Patient Care

    Get PDF
    Technology found in modern fitness sensor devices advances at a very fast pace and current smartwatches are on the verge of closing the gap between being an everyday object and a medically reliable monitoring device. In this thesis, the possibility of adopting fitness sensor devices in medical environments is explored and use cases in which sensor devices can be deployed are examined. Their successful transfer from the area of sports to medical analyses and treatments may help patients to deal with their illnesses and to improve the level of patient care found today. Privacy and security issues as well as social concerns associated with such a disruptive evolution are discussed and practical tests of a pulse oximeter in various activities of daily living are conducted. The collected health data depicts a close representation of the performed activities. Furthermore, three types of fitness sensor devices were used in different real-life scenarios and the resulting data is compared. The results show that the recorded vital signs may differ significantly, depending on the scenario. ii

    2016 Laura and John Arnold Foundation Annual Report

    Get PDF
    2016 Annual Repor

    Sensing human activity to improve sedentary lifestyle

    Get PDF
    Recent public health campaigns often communicate the alarming phrase: “Sitting is the new smoking”. Sitting is related to all-cause mortality, cardiovascular disease, type 2 diabetes, and metabolic syndrome. Sedentary behavior is generally understood as “sitting or reclining while expending ≀1.5 metabolic equivalents” and the interesting aspect of sedentary behavior is that it is a modifiable health risk. The health risk can be reduced if a person changes his or her behavior towards a healthier one; to sit less and to become more physically active. Research focusing on patterns of sedentary behavior has taken off since the rise of both wearable technologies and activity sensors. They provide opportunities for uncovering sedentary patterns within the context of daily life. As a consequence, the sedentary research field moved forward towards fine-grained, objective monitoring of sedentary behavior in free-living conditions for substantial time frames. Current wearable activity sensors are, however, not flawless in measuring sedentary behavior. It is therefore important to understand the effects of possible measurement bias, in order to deal with it in the best way. People are often unaware of their sedentary behavior, making it difficult to change the behavior. mHealth interventions can improve awareness and trigger behavior change by tailoring the intervention to the user’s needs by providing direct feedback and coaching on physical activity and sedentary behavior together with real-time information on the context. Context information can be gathered by integrating relevant data sources or by posing questions about the here-and-now. Further increase of acceptance of mHealth interventions can be achieved by tailoring to individual values, and barriers and facilitators to these values. The aim of this thesis is to determine how wearable activity sensors can be applied successfully in health interventions focused on sedentary behavior. This thesis follows an expanding scope: starting from the level of the activity sensor up to the level of public health. The first part of this thesis focuses on the measurement of sedentary behavior and its patterns by means of wearable activity sensors (Chapter 2, 3 and 4). The second part of this thesis focuses on the development and evaluation of mHealth interventions that utilize these wearable activity sensors (Chapter 5 and 6). The pattern of sedentary behavior during the day is an independent health risk. Prolonged sedentary time affects cardio-metabolic and inflammatory biomarkers, independent of the total sedentary time. Since the rise of both wearable technologies and activity sensors, there is however, no consensus among researchers on the best outcome measures for representing the sedentary pattern during the day, based on wearable activity sensors. Chapter 2 provides an overview of current pattern measures of sedentary behavior in adults, by means of a literature review. Simple measures of sedentary behavior were most often reported, like the number of bouts, the medium or median bout length. More complex pattern measures, such as the GINI index or the W50 were reported sparsely. Due to the differences among measurement devices, data analysis protocols and a lack of basic outcome parameters such as total wear-time and total sedentary time, the sedentary patterns, reported in the various studies, were difficult to compare. The simple and complex measures of sedentary time accumulation serve different goals, varying from a quick overview to in-depth analysis and prediction of behavior. The answer to which measures are most suitable to report, is therefore strongly dependent on the research question. From this overview in Chapter 2 we conclude that the reported measures were dependent on 1) the sensing method, 2) the classification method, 3) the experimental and data cleaning protocol, and 4) the applied definitions of bouts and breaks. Based on these findings, we recommend to always report total wear-time, total sedentary time, number of bouts and at least one measure describing the diversity of bout lengths in the sedentary behavior such as the W50. Additionally, we recommend to report the measurement conditions and data processing steps. One of the factors influencing the output of activity sensors mentioned above is the experimental protocol (Chapter 2). This was studied in more depth in Chapter 3 in which we focused on optimal sensor placement for measuring physical activity. Subjects walked at various speeds on a treadmill, performed a deskwork protocol, and walked on level ground, while simultaneously wearing five activity sensors with a snug fit on an elastic waist belt. We found that sensor location, type of activity, and their interaction-effect affected sensor output. The most lateral positions on the waist belt were the least sensitive for interference. Additionally, the effect of mounting was explored by repeating the experimental protocol with sensors more loosely fitted to the elastic belt. The loose fit resulted in lower sensor output, except for the deskwork protocol, where output was higher. We conclude that, in order to increase the reliability and to reduce the variability of sensor output, researchers should place activity sensors on the most lateral position of a participant‘s waist belt. If the sensor hampers free movement, it may be positioned slightly more forward on the belt. Finally, we recommend to wear sensors tightly fitted to the body. Another factor influencing the output of activity sensors mentioned above (Chapter 2) is the classification method. Currently, the most applied method to distinguish sedentary from active time is by applying a cut-point to accelerometry-based data. This means that the intensity of the measured behavior is classified as being sedentary when below this cut-point. The effect of the classification method on sedentary pattern measures was studied in detail in laboratory and free-living conditions with office workers (Chapter 4). In this study we found that the outcome measures are robust – meaning that the outcome measures do not change –, when cut-points for classifying sedentary behavior are within the boundaries of ±10-20% of the optimal cut-point. This conclusion implies that results from studies analyzing sedentary patterns based on different cut-points, can only be compared if the cut-points are within these boundaries. In Chapter 5, we combined the knowledge on sensor use, data processing steps and outcome measures with context-aware technology in an intervention for older office workers towards sitting less and breaking up sitting time. Office workers spend a high percentage of their time sitting, often in long periods of time. Research suggests that it is healthier to break these long bouts into shorter periods by being physically active. In order to promote breaking up long sedentary bouts, we developed an innovative, context-aware activity coach for older office workers. This coach provides activity suggestions, based on a physical activity prediction model, consisting of past and current physical activity (measured by a wearable activity sensor) and digital agendas. The total sedentary time in the intervention week, was not reduced compared to the baseline week. However, the pattern of the sedentary behaviour did change – the office workers reduced their total time spent in long sitting bouts (≄45 minutes). Additionally, the office workers indicated that the main added value of the intervention resided in creating awareness about their personal sedentary behaviour pattern. Finally, the participants were compliant to 53% of the suggestions; a number that could be increased by improving the timing of suggestions. We conclude that the mobile intervention (using an activity sensor, smartphone application and context information) has the potential to improve the sedentary behaviour of older office workers. The gain can especially be found in breaking up long sedentary periods by being physically active. Older office workers value that it makes them aware of their sedentary behaviour. We also found that focusing on total sedentary time as an outcome of a public health intervention, aimed at reducing sedentary behaviour, is too simplistic. Rather, one should take into account both the duration and the number of bouts when determining the effect of the intervention. We conclude this article by summarizing our design recommendations for eHealth interventions that aim to improve sedentary behaviour. In Chapter 6 we focused on a design approach to further increase acceptance of mHealth interventions – by tailoring to individual values, and barriers and facilitators to these values. In this study, we demonstrated how value-based design can contribute to the design of a product or service that addresses real needs and thus, lead to high acceptance. We described the methods and application of value-based design. We elicited values, facilitators and barriers of their reduced mobility – meaning difficulty with walking, biking, and/or activities of daily living – of older adults via in-depth interviews. These interviews resulted in a myriad of key values, such as ‘independence from family’ and ‘doing their own groceries’. Co-creation design sessions resulted in innovative mobility aids from which three designs for a wheeled walker were selected for evaluation on acceptance, again via in-depth interviews. Their acceptance was rather low. Current mobility device users were more eager to accept the designs than non-users. The value-based approach offered designers a close look into the lives of the elderly, thereby opening up a wide range of innovation possibilities that better fit the actual needs. However, mobility is related to physical capacity and not being sedentary. In-depth understanding of the values of life to be mobile, can therefore directly inspire designers focused on mobility aids. Nevertheless, this understanding can as well tap into the context and personal goals needed to tailor health interventions on sedentary behavior. In Chapter 7, the general discussion, we discuss the rapid development of sensors and analysis methods, as well as gathering rich context information by means Experience Sampling. Cut-point-based analyses make only very limited use of the wealth of data that can be measured by activity sensors and has various challenges which hinders generalization of the current body of knowledge (Chapter 2, 3 and 4). It seems to make more sense to express the measured behavior in terms of the actual behavior, such as bicycling and climbing stairs, rather than expressing physical activity in counts or metric units representing its intensity. Machine learning techniques are very capable of this with higher accuracy, and their application seems to be a logical step forwards. And when expressed as behavior, machine learning output will be easier to adopt in interventions, as total sitting time and active breaks are better understandable than for example counts – matching the real-world knowledge of users. The Experience Sampling Method (ESM) incorporated in the developed intervention (Chapter 5) provided in-depth understanding of the context of sedentary behavior – the where, when, why, with whom and experienced emotions. Future interventions should incorporate this type of context-awareness in real-time tailored coaching strategies to increase awareness and behavior change. The studies in this thesis have shown that activity sensors can provide valuable information on the pattern of sedentary behavior, and that these can be useful for health interventions. We have shown the strengths of current practice and opportunities for improvement, by applying a broad scope with a focus on measuring sedentary behavior and developing and evaluating mHealth interventions. Based on the study we conclude that: The combination of the bottom-up approach (from sensor, to data to information levels) and the top-down approach (from user values related to public health to interventions and its specific feedback and coaching strategies), contribute to diverse, strongly connected and interdependent domains of applying wearable activity sensors in health interventions focused on sedentary behavior
    • 

    corecore