697 research outputs found

    Development of a Real-Time Single-Lead Single-Beat Frequency-Independent Myocardial Infarction Detector

    Get PDF
    The central aim of this research is the development and deployment of a novel multilayer machine learning design with unique application for the diagnosis of myocardial infarctions (MIs) from individual heartbeats of single-lead electrocardiograms (EKGs) irrespective of their sampling frequencies over a given range. To the best of our knowledge, this design is the first to attempt inter-patient myocardial infarction detection from individual heartbeats of single-lead (lead II) electrocardiograms that achieves high accuracy and near real-time diagnosis. The processing time of 300 milliseconds to a diagnosis is just at the time range in between extremely fast heartbeats of around 300 milliseconds, or 200 beats per minute. The design achieves stable performance metrics over the frequency range of 202Hz to 2.8kHz with an accuracy of 77.12%, positive predictive value (PPV) of 75.85%, and a negative predictive value (NPV) of 83.02% over the entire PTB database; 85.07%, 81.54%, 87.31% over the PTB-XL (the largest EKG database available for research) validation set, and 84.17%, 78.37%, 87.55% over the PTB-XL test set. Major design contributions and findings of this work reveal (1) a method for the realtime detection of ventricular depolarization events in the PQRST complex from 12-lead electrocardiograms using Independent Component Analysis (ICA), with a slightly different use of ICA proposed for electrocardiogram analysis and R-peak detection/localization; (2) a multilayer Long-Short Term Memory (LSTM) neural network design that identifies infarcted patients from a single heartbeat of a single-lead (lead II) electrocardiogram; (3) and integrated LSTM neural network with an algorithm that detects the R-peaks in real time for instantaneous detection of myocardial infarctions and for effective monitoring of patients under cardiac stress and/or at risk of myocardial infarction; (4) a fully integrated 12-lead real-time classifier with even higher detection metrics and a deeper neural architecture, which could serve as a near real-time monitoring tool that could gauge disease progression and evaluate benefits gained from early intervention and treatment planning; (5) a real-time frequency-independent design based on a single-lead single-beat MI detector, which is of pivotal importance to deployment as there is no standard sampling frequency for EKGs, making them span a wider frequency spectrum. vi

    Detection and analysis of heartbeats in seismocardiogram signals

    Get PDF
    This paper presents an unsupervised methodology to analyze SeismoCardioGram (SCG) signals. Starting from raw accelerometric data, heartbeat complexes are extracted and annotated, using a two-step procedure. An unsupervised calibration procedure is added to better adapt to different user patterns. Results show that the performance scores achieved by the proposed methodology improve over related literature: on average, 98.5% sensitivity and 98.6% precision are achieved in beat detection, whereas RMS (Root Mean Square) error in heartbeat interval estimation is as low as 4.6 ms. This allows SCG heartbeat complexes to be reliably extracted. Then, the morphological information of such waveforms is further processed by means of a modular Convolutional Variational AutoEncoder network, aiming at extracting compressed, meaningful representation. After unsupervised training, the VAE network is able to recognize different signal morphologies, associating each user to its specific patterns with high accuracy, as indicated by specific performance metrics (including adjusted random and mutual information score, completeness, and homogeneity). Finally, a Linear Model is used to interpret the results of clustering in the learned latent space, highlighting the impact of different VAE architectural parameters (i.e., number of stacked convolutional units and dimension of latent space)

    Signal processing methodologies for an acoustic fetal heart rate monitor

    Get PDF
    Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use

    Biomedical Applications of the Discrete Wavelet Transform

    Get PDF

    Advanced Biometrics with Deep Learning

    Get PDF
    Biometrics, such as fingerprint, iris, face, hand print, hand vein, speech and gait recognition, etc., as a means of identity management have become commonplace nowadays for various applications. Biometric systems follow a typical pipeline, that is composed of separate preprocessing, feature extraction and classification. Deep learning as a data-driven representation learning approach has been shown to be a promising alternative to conventional data-agnostic and handcrafted pre-processing and feature extraction for biometric systems. Furthermore, deep learning offers an end-to-end learning paradigm to unify preprocessing, feature extraction, and recognition, based solely on biometric data. This Special Issue has collected 12 high-quality, state-of-the-art research papers that deal with challenging issues in advanced biometric systems based on deep learning. The 12 papers can be divided into 4 categories according to biometric modality; namely, face biometrics, medical electronic signals (EEG and ECG), voice print, and others
    corecore