1,985 research outputs found

    Virtual prototyping of a semi-active transfemoral prosthetic leg

    Get PDF
    This article presents a virtual prototyping study of a semi-active lower limb prosthesis to improve the functionality of an amputee during prosthesis–environment interaction for level ground walking. Articulated ankle–foot prosthesis and a single-axis semi-active prosthetic knee with active and passive operating modes were considered. Data for level ground walking were collected using a photogrammetric method in order to develop a base-line simulation model and with the hip kinematics input to verify the proposed design. The simulated results show that the semi-active lower limb prosthesis is able to move efficiently in passive mode, and the activation time of the knee actuator can be reduced by approximately 50%. Therefore, this semi-active system has the potential to reduce the energy consumption of the actuators required during level ground walking and requires less compensation from the amputee due to lower deviation of the vertical excursion of body centre of mass

    Towards a Smart Semi-Active Prosthetic Leg: Preliminary Assessment and Testing

    Get PDF
    This paper presents a development of a semi-active prosthetic knee, which can work in both active and passive modes based on the energy required during the gait cycle of various activities of daily livings (ADLs). The prosthetic limb is equipped with various sensors to measure the kinematic and kinetic parameters of both prosthetic limbs. This prosthetic knee is designed to be back-drivable in passive mode to provide a potential use in energy regeneration when there negative energy across the knee joint. Preliminary test has been performed on transfemoral amputee in passive mode to provide some insight to the amputee/prosthesis interaction and performance with the designed prosthetic knee

    Transverse rotation and longitudinal translation during prosthetic gait - a literature review

    Get PDF
    Improved technology allows for more accurate gait analysis to increase awareness of nonoptimized prosthetic gait patterns and for the manufacture of sophisticated prosthetic components to improve nonoptimized gait patterns. However, prescriptions are often based on intuition rather than rigorous research findings for evidence-based practice. The number of studies found in the literature that are based on prosthetic research regarding transverse rotation and longitudinal translation is small when compared to topics regarding other types of movements. Some design criteria for prosthetic components described in those studies that permit transverse rotation and longitudinal translation can be found in current designs. However, little research has been conducted to establish their effectiveness on the gait parameters and residual limb. This literature review is an investigation into these motions between the socket and the prosthetic foot, with particular reference to gait characteristics and prosthetic design criteria

    Design, Control, and Optimization of Robots with Advanced Energy Regenerative Drive Systems

    Get PDF
    We investigate the control and optimization of robots with ultracapacitor based regenerative drive systems. A subset of the robot joints are conventional, in the sense that external power is used for actuation. Other joints are energetically self-contained passive systems that use ultracapacitors for energy storage. An electrical interconnection known as the star configuration is considered for the regenerative drives that allows for direct electric energy redistribution among joints, and enables higher energy utilization efficiencies. A semi-active virtual control strategy is used to achieve control objectives. We find closed-form expressions for the optimal robot and actuator parameters (link lengths, gear ratios, etc.) that maximize energy regeneration between any two times, given motion trajectories. In addition, we solve several trajectory optimization problems for maximizing energy regeneration that admit closed-form solutions, given system parameters. Optimal solutions are shown to be global and unique. In addition, closed-form expressions are provided for the maximum attainable energy. This theoretical maximum places limits on the amount of energy that can be recovered. Numerical examples are provided in each case to demonstrate the results. For problems that don\u27t admit analytical solutions, we formulate the general nonlinear optimal control problem, and solve it numerically, based on the direct collocation method. The optimization problem, its numerical solution and an experimental evaluation are demonstrated using a PUMA manipulator with custom regenerative drives. Power flows, stored regenerative energy and efficiency are evaluated. Experimental results show that when following optimal trajectories, a reduction of about 10-22% in energy consumption can be achieved. Furthermore, we present the design, control, and experimental evaluation of an energy regenerative powered transfemoral prosthesis. Our prosthesis prototype is comprised of a passive ankle, and an active regenerative knee joint. A novel varying impedance control approach controls the prosthesis in both the stance and swing phase of the gait cycle, while explicitly considering energy regeneration. Experimental evaluation is done with an amputee test subject walking at different speeds on a treadmill. The results validate the effectiveness of the control method. In addition, net energy regeneration is achieved while walking with near-natural gait across all speeds

    Optimal Mixed Tracking/Impedance Control With Application to Transfemoral Prostheses With Energy Regeneration

    Get PDF
    We design an optimal passivitybased tracking/impedance control system for a robotic manipulator with energy regenerative electronics, where the manipulator has both actively and semi-actively controlled joints. The semi-active joints are driven by a regenerative actuator that includes an energy-storing element. Method: External forces can have a large influence on energy regeneration characteristics. Impedance control is used to impose a desired relationship between external forces and deviation from reference trajectories. Multi-objective optimization (MOO) is used to obtain optimal impedance parameters and control gains to compromise between the two conflicting objectives of trajectory tracking and energy regeneration. We solve the MOO problem under two different scenarios: 1) constant impedance; and 2) timevarying impedance. Results: The methods are applied to a transfemoral prosthesis simulation with a semi-active knee joint. Normalized hypervolume and relative coverage are used to compare Pareto fronts, and these two metrics show that time-varying impedance provides better performance than constant impedance. The solution with time-varying impedance with minimum tracking error (0.0008 rad) fails to regenerate energy (loses 9.53 J), while a solution with degradation in tracking (0.0452 rad) regenerates energy (gains 270.3 J). A tradeoff solution results in fair tracking (0.0178 rad) and fair energy regeneration (131.2 J). Conclusion: Our experimental results support the possibility of net energy regeneration at the semi-active knee joint with human-like tracking performance. Significance: The results indicate that advanced control and optimization of ultracapacitor-based systems can significantly reduce power requirements in transfemoral prostheses

    Conceptual Design of a Fully Passive Transfemoral Prosthesis to Facilitate Energy-Efficient Gait

    Get PDF
    In this study, we present the working principle and conceptual design towards the realization of a fully-passive transfemoral prosthesis that mimics the energetics of the natural human gait. The fundamental property of the conceptual design consists of realizing an energetic coupling between the knee and ankle joints of the mechanism. Simulation results show that the power flow of the working principle is comparable to that in human gait and a considerable amount of energy is delivered to the ankle joint for the push-off generation. An initial prototype in half scale is realized to validate the working principle. The construction of the prototype is explained together with the test setup that has been built for the evaluation. Finally, experimental results of the prosthesis prototype during walking on a treadmill show the validity of the working principle

    Human-activity-centered measurement system:challenges from laboratory to the real environment in assistive gait wearable robotics

    Get PDF
    Assistive gait wearable robots (AGWR) have shown a great advancement in developing intelligent devices to assist human in their activities of daily living (ADLs). The rapid technological advancement in sensory technology, actuators, materials and computational intelligence has sped up this development process towards more practical and smart AGWR. However, most assistive gait wearable robots are still confined to be controlled, assessed indoor and within laboratory environments, limiting any potential to provide a real assistance and rehabilitation required to humans in the real environments. The gait assessment parameters play an important role not only in evaluating the patient progress and assistive device performance but also in controlling smart self-adaptable AGWR in real-time. The self-adaptable wearable robots must interactively conform to the changing environments and between users to provide optimal functionality and comfort. This paper discusses the performance parameters, such as comfortability, safety, adaptability, and energy consumption, which are required for the development of an intelligent AGWR for outdoor environments. The challenges to measuring the parameters using current systems for data collection and analysis using vision capture and wearable sensors are presented and discussed

    Sci Robot

    Get PDF
    Robotic leg prostheses promise to improve the mobility and quality of life of millions of individuals with lower-limb amputations by imitating the biomechanics of the missing biological leg. Unfortunately, existing powered prostheses are much heavier and bigger and have shorter battery life than conventional passive prostheses, severely limiting their clinical viability and utility in the daily life of amputees. Here, we present a robotic leg prosthesis that replicates the key biomechanical functions of the biological knee, ankle, and toe in the sagittal plane while matching the weight, size, and battery life of conventional microprocessor-controlled prostheses. The powered knee joint uses a unique torque-sensitive mechanism combining the benefits of elastic actuators with that of variable transmissions. A single actuator powers the ankle and toe joints through a compliant, underactuated mechanism. Because the biological toe dissipates energy while the biological ankle injects energy into the gait cycle, this underactuated system regenerates substantial mechanical energy and replicates the key biomechanical functions of the ankle/foot complex during walking. A compact prosthesis frame encloses all mechanical and electrical components for increased robustness and efficiency. Preclinical tests with three individuals with above-knee amputation show that the proposed robotic leg prosthesis allows for common ambulation activities with close to normative kinematics and kinetics. Using an optional passive mode, users can walk on level ground indefinitely without charging the battery, which has not been shown with any other powered or microprocessor-controlled prostheses. A prosthesis with these characteristics has the potential to improve real-world mobility in individuals with above-knee amputation.R01 HD098154/HD/NICHD NIH HHSUnited States/T42 OH008414/OH/NIOSH CDC HHSUnited States
    • …
    corecore