5,332 research outputs found

    Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review

    Get PDF
    Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.Web of Science1923art. no. 519

    Computer- and robot-assisted Medical Intervention

    Full text link
    Medical robotics includes assistive devices used by the physician in order to make his/her diagnostic or therapeutic practices easier and more efficient. This chapter focuses on such systems. It introduces the general field of Computer-Assisted Medical Interventions, its aims, its different components and describes the place of robots in that context. The evolutions in terms of general design and control paradigms in the development of medical robots are presented and issues specific to that application domain are discussed. A view of existing systems, on-going developments and future trends is given. A case-study is detailed. Other types of robotic help in the medical environment (such as for assisting a handicapped person, for rehabilitation of a patient or for replacement of some damaged/suppressed limbs or organs) are out of the scope of this chapter.Comment: Handbook of Automation, Shimon Nof (Ed.) (2009) 000-00

    Non-invasive quantification of lower limb mechanical alignment in flexion

    Get PDF
    Objective: Non-invasive navigation techniques have recently been developed to determine mechanical femorotibial alignment (MFTA) in extension. The primary aim of this study was to evaluate the precision and accuracy of an image-free navigation system with new software designed to provide multiple kinematic measurements of the knee. The secondary aim was to test two types of strap material used to attach optical trackers to the lower limb. Methods: Seventy-two registrations were carried out on 6 intact embalmed cadaveric specimens (mean age: 77.8 ± 12 years). A validated fabric strap, bone screws and novel rubber strap were used to secure the passive tracker baseplate for four full experiments with each knee. The MFTA angle was measured under the conditions of no applied stress, valgus stress, and varus stress. These measurements were carried out at full extension and at 30°, 40°, 50° and 60° of flexion. Intraclass correlation coefficients, repeatability coefficients, and limits of agreement (LOA) were used to convey precision and agreement in measuring MFTA with respect to each of the independent variables, i.e., degree of flexion, applied coronal stress, and method of tracker fixation. Based on the current literature, a repeatability coefficient and LOA of ≤3° were deemed acceptable. Results: The mean fixed flexion for the 6 specimens was 12.8° (range: 6–20°). The mean repeatability coefficient measuring MFTA in extension with screws or fabric strapping of the baseplate was ≤2°, compared to 2.3° using rubber strapping. When flexing the knee, MFTA measurements taken using screws or fabric straps remained precise (repeatability coefficient ≤3°) throughout the tested range of flexion (12.8–60°); however, using rubber straps, the repeatability coefficient was >3° beyond 50° flexion. In general, applying a varus/valgus stress while measuring MFTA decreased precision beyond 40° flexion. Using fabric strapping, excellent repeatability (coefficient ≤2°) was observed until 40° flexion; however, beyond 50° flexion, the repeatability coefficient was >3°. As was the case with precision, agreement between the invasive and non-invasive systems was satisfactory in extension and worsened with flexion. Mean limits of agreement between the invasive and non-invasive system using fabric strapping to assess MFTA were 3° (range: 2.3–3.8°) with no stress applied and 3.9° (range: 2.8–5.2°) with varus and valgus stress. Using rubber strapping, the corresponding values were 4.4° (range: 2.8–8.5°) with no stress applied, 5.5° (range: 3.3–9.0°) with varus stress, and 5.6° (range: 3.3–11.9°) with valgus stress. Discussion: Acceptable precision and accuracy may be possible when measuring knee kinematics in early flexion using a non-invasive system; however, we do not believe passive trackers should be mounted with rubber strapping such as was used in this study. Flexing the knee appears to decrease the precision and accuracy of the system. The functions of this new software using image-free navigation technology have many potential clinical applications, including assessment of bony and soft tissue deformity, pre-operative planning, and post-operative evaluation, as well as in further pure research comparing kinematics of the normal and pathological knee

    Radiological Society of North America (RSNA) 3D printing Special Interest Group (SIG): Guidelines for medical 3D printing and appropriateness for clinical scenarios

    Get PDF
    Este número da revista Cadernos de Estudos Sociais estava em organização quando fomos colhidos pela morte do sociólogo Ernesto Laclau. Seu falecimento em 13 de abril de 2014 surpreendeu a todos, e particularmente ao editor Joanildo Burity, que foi seu orientando de doutorado na University of Essex, Inglaterra, e que recentemente o trouxe à Fundação Joaquim Nabuco para uma palestra, permitindo que muitos pudessem dialogar com um dos grandes intelectuais latinoamericanos contemporâneos. Assim, buscamos fazer uma homenagem ao sociólogo argentino publicando uma entrevista inédita concedida durante a sua passagem pelo Recife, em 2013, encerrando essa revista com uma sessão especial sobre a sua trajetória

    Robot Autonomy for Surgery

    Full text link
    Autonomous surgery involves having surgical tasks performed by a robot operating under its own will, with partial or no human involvement. There are several important advantages of automation in surgery, which include increasing precision of care due to sub-millimeter robot control, real-time utilization of biosignals for interventional care, improvements to surgical efficiency and execution, and computer-aided guidance under various medical imaging and sensing modalities. While these methods may displace some tasks of surgical teams and individual surgeons, they also present new capabilities in interventions that are too difficult or go beyond the skills of a human. In this chapter, we provide an overview of robot autonomy in commercial use and in research, and present some of the challenges faced in developing autonomous surgical robots

    A Review of Virtual Reality Based Training Simulators for Orthopaedic Surgery

    Get PDF
    This review presents current virtual reality based training simulators for hip, knee and other orthopaedic surgery, including elective and trauma surgical procedures. There have not been any reviews focussing on hip and knee orthopaedic simulators. A comparison of existing simulator features is provided to identify what is missing and what is required to improve upon current simulators. In total 11 total hip replacement pre-operative planning tools were analysed, plus 9 hip trauma fracture training simulators. Additionally 9 knee arthroscopy simulators and 8 other orthopaedic simulators were included for comparison. The findings are that for orthopaedic surgery simulators in general, there is increasing use of patient-specific virtual models which reduce the learning curve. Modelling is also being used for patient-specific implant design and manufacture. Simulators are being increasingly validated for assessment as well as training. There are very few training simulators available for hip replacement, yet more advanced virtual reality is being used for other procedures such as hip trauma and drilling. Training simulators for hip replacement and orthopaedic surgery in general lag behind other surgical procedures for which virtual reality has become more common. Further developments are required to bring hip replacement training simulation up to date with other procedures. This suggests there is a gap in the market for a new high fidelity hip replacement and resurfacing training simulator

    A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS). Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre.</p> <p>Methods</p> <p>A custom made neck jig device is presented as well as the results of a pilot study.</p> <p>The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned.</p> <p>Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation.</p> <p>Results</p> <p>The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife contact with femoral head, positive. There were no guide failures. The jig unique position and the number of steps required to put the guide in place were rated 1, while the complexity to put the guide into place was rated 1-2. In all five cases the guide wire was accurately positioned. Maximum angular deviation was 2.9° and maximum distance between insertion points was 2.1 mm.</p> <p>Conclusions</p> <p>Pilot testing of a custom made jig for use during SRA indicated that the device was (1) successfully applied and user friendly and (2) allowed for accurate guide wire placement according to the preoperative plan.</p
    corecore