38 research outputs found

    Design and implementation of a multi-octave-band audio camera for realtime diagnosis

    Full text link
    Noise pollution investigation takes advantage of two common methods of diagnosis: measurement using a Sound Level Meter and acoustical imaging. The former enables a detailed analysis of the surrounding noise spectrum whereas the latter is rather used for source localization. Both approaches complete each other, and merging them into a unique system, working in realtime, would offer new possibilities of dynamic diagnosis. This paper describes the design of a complete system for this purpose: imaging in realtime the acoustic field at different octave bands, with a convenient device. The acoustic field is sampled in time and space using an array of MEMS microphones. This recent technology enables a compact and fully digital design of the system. However, performing realtime imaging with resource-intensive algorithm on a large amount of measured data confronts with a technical challenge. This is overcome by executing the whole process on a Graphic Processing Unit, which has recently become an attractive device for parallel computing

    Ultrasound Beamforming on a FPGA

    Get PDF

    Ultrasound Open Platforms for Next-Generation Imaging Technique Development

    Get PDF
    Open platform (OP) ultrasound systems are aimed primarily at the research community. They have been at the forefront of the development of synthetic aperture, plane wave, shear wave elastography, and vector flow imaging. Such platforms are driven by a need for broad flexibility of parameters that are normally preset or fixed within clinical scanners. OP ultrasound scanners are defined to have three key features including customization of the transmit waveform, access to the prebeamformed receive data, and the ability to implement real-time imaging. In this paper, a formative discussion is given on the development of OPs from both the research community and the commercial sector. Both software- and hardware-based architectures are considered, and their specifications are compared in terms of resources and programmability. Software-based platforms capable of real-time beamforming generally make use of scalable graphics processing unit architectures, whereas a common feature of hardware-based platforms is the use of field-programmable gate array and digital signal processor devices to provide additional on-board processing capacity. OPs with extended number of channels (>256) are also discussed in relation to their role in supporting 3-D imaging technique development. With the increasing maturity of OP ultrasound scanners, the pace of advancement in ultrasound imaging algorithms is poised to be accelerated

    Portable Ultrasound Imaging

    Get PDF
    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs of the ultrasound system and, consequently, to allow for a wide-scale utilization of diagnostic ultrasound in any medical specialties and out of the radiology department. The first part of the contribution deals with the study of hardware solutions for the reduction of the system complexity. Analog and digital beamforming strategies are simulated from a system-level perspective. The quality of the B-mode image is evaluated and the minimum specifications are derived for the design of a portable probe with integrated electronics in-handle. The system is based on a synthetic aperture sequential beamforming approach that allows to significantly reduce the data rate between the probe and processing unit. The second part investigates the feasibility of vector flow imaging in a hand-held ultrasound system. Vector flow imaging overcomes the limitations of conventional imaging methods in terms of flow angle compensation. Furthermore, high frame rate can be obtained by using synthetic aperture focusing techniques. A method is developed combining synthetic aperture sequential beamforming and directional transverse oscillation to achieve the wireless transmission of the data along with a relatively inexpensive 2-D velocity estimation. The performance of the method is thoroughly assessed through simulations and measurements, and in vivo investigations are carried out to show its potential in presence of complex flow dynamics. A sufficient frame rate is achieved to allow for the visualization of vortices in the carotid bifurcation. Furthermore, the method is implemented on a commercially available tablet to evaluate the real-time processing performance in the built-in GPU with concurrent wireless transmission of the data. Based on the demonstrations in this thesis, a flexible framework can be implemented with performance that can be scaled to the needs of the user and according to the computing resources available. The integration of high-frame-rate vector flow imaging in a hand-held ultrasound scanner, in addition, has the potential to improve the operator’s workflow and opens the way to new possibilities in the clinical practice

    Efficient architectures of heterogeneous fpga-gpu for 3-d medical image compression

    Get PDF
    The advent of development in three-dimensional (3-D) imaging modalities have generated a massive amount of volumetric data in 3-D images such as magnetic resonance imaging (MRI), computed tomography (CT), positron emission tomography (PET), and ultrasound (US). Existing survey reveals the presence of a huge gap for further research in exploiting reconfigurable computing for 3-D medical image compression. This research proposes an FPGA based co-processing solution to accelerate the mentioned medical imaging system. The HWT block implemented on the sbRIO-9632 FPGA board is Spartan 3 (XC3S2000) chip prototyping board. Analysis and performance evaluation of the 3-D images were been conducted. Furthermore, a novel architecture of context-based adaptive binary arithmetic coder (CABAC) is the advanced entropy coding tool employed by main and higher profiles of H.264/AVC. This research focuses on GPU implementation of CABAC and comparative study of discrete wavelet transform (DWT) and without DWT for 3-D medical image compression systems. Implementation results on MRI and CT images, showing GPU significantly outperforming single-threaded CPU implementation. Overall, CT and MRI modalities with DWT outperform in term of compression ratio, peak signal to noise ratio (PSNR) and latency compared with images without DWT process. For heterogeneous computing, MRI images with various sizes and format, such as JPEG and DICOM was implemented. Evaluation results are shown for each memory iteration, transfer sizes from GPU to CPU consuming more bandwidth or throughput. For size 786, 486 bytes JPEG format, both directions consumed bandwidth tend to balance. Bandwidth is relative to the transfer size, the larger sizing will take more latency and throughput. Next, OpenCL implementation for concurrent task via dedicated FPGA. Finding from implementation reveals, OpenCL on batch procession mode with AOC techniques offers substantial results where the amount of logic, area, register and memory increased proportionally to the number of batch. It is because of the kernel will copy the kernel block refer to batch number. Therefore memory bank increased periodically related to kernel block. It was found through comparative study that the tree balance and unroll loop architecture provides better achievement, in term of local memory, latency and throughput

    Ultrafast Ultrasound Imaging

    Get PDF
    Among medical imaging modalities, such as computed tomography (CT) and magnetic resonance imaging (MRI), ultrasound imaging stands out due to its temporal resolution. Owing to the nature of medical ultrasound imaging, it has been used for not only observation of the morphology of living organs but also functional imaging, such as blood flow imaging and evaluation of the cardiac function. Ultrafast ultrasound imaging, which has recently become widely available, significantly increases the opportunities for medical functional imaging. Ultrafast ultrasound imaging typically enables imaging frame-rates of up to ten thousand frames per second (fps). Due to the extremely high temporal resolution, this enables visualization of rapid dynamic responses of biological tissues, which cannot be observed and analyzed by conventional ultrasound imaging. This Special Issue includes various studies of improvements to the performance of ultrafast ultrasoun

    Autoenfoque en imagen ultrasónica

    Get PDF
    La inspección de componentes por ultrasonidos se realiza, actualmente, con sistemas de imagen phased array, versión industrial de los ecógrafos médicos. En ambos casos se utiliza un array con decenas o centenares de pequeños transductores piezoeléctricos que se controlan individualmente para enfocar y deflectar el haz ultrasónico en emisión y recepción. Pero, mientras que en medicina el array está en contacto con el cuerpo, que es flexible, en la industria se suele interponer un medio acoplante entre el array y el componente a inspeccionar. Cuando la geometría de la pieza no es plana se utiliza agua como medio acoplante, que se adapta a la forma de la pieza y proporciona un medio continuo y de baja atenuación para la transmisión del sonido. En estas condiciones existen dos medios de propagación, lo que dificulta la determinación de los retardos de enfoque por efectos de la refracción. Como en estas condiciones no existen fórmulas cerradas que faciliten su cálculo, hasta la fecha se han venido utilizando procesos iterativos computacionalmente costosos que impiden la modificación rápida del enfoque cuando varía la geometría de la pieza (por ejemplo, durante la realización de un barrido). Estas razones han impedido el desarrollo de técnicas de autoenfoque efectivas. Esta Tesis aporta tres técnicas que, junto al cálculo en tiempo real de los parámetros de enfoque y un soporte arquitectural de imagen a ultra-alta velocidad, están entre las primeras aproximaciones reales para solucionar el problema del autoenfoque en imagen ultrasónica. De hecho, una de ellas (AUTOFOCUS) ha sido patentada y transferida a la industria, que la comercializa en equipos phased array con esta capacidad. La memoria describe las motivaciones, fundamentos, aproximaciones conocidas al problema así como las dificultades y las soluciones investigadas. Una segunda parte incluye las publicaciones más relevantes donde se han comunicado los resultados, contrastando los teóricamente esperados con los experimentalmente obtenidos

    Real-Time Narrowband and Wideband Beamforming Techniques for Fully-Digital RF Arrays

    Get PDF
    Elemental digital beamforming offers increased flexibility for multi-function radio frequency (RF) systems supporting radar and communications applications. As fully digital arrays, components, and subsystems are becoming more affordable in the military and commercial industries, analog components such as phase shifters, filters, and mixers have begun to be replaced by digital circuits which presents efficiency challenges in power constrained scenarios. Furthermore, multi-function radar and communications systems are exploiting the multiple simultaneous beam capability provided by digital at every element beamforming. Along with further increasing data samples rates and increasing instantaneous bandwidths (IBW), real time processing in the digital domain has become a challenge due to the amount of data produced and processed in current systems. These arrays generate hundreds of gigabits per second of data throughput or more which is costly to send off-chip to an adjunct processor fundamentally limiting the overall performance of an RF array system. In this dissertation, digital filtering techniques and architectures are described which calibrate and beamform both narrowband and wideband RF arrays on receive. The techniques are shown to optimize one or many parameters of the digital transceiver system to improve the overall system efficiency. Digitally beamforming in the beamspace is shown to further increase the processing efficiency of an adaptive system compared to state of the art frequency domain approaches by minimizing major processing bottlenecks of generating adaptive filter coefficients. The techniques discussed are compared and contrasted across different hardware processor modules including field-programmable gate arrays (FPGAs), graphical processing units (GPUs), and central processing units (CPUs)

    Ultrasound Imaging

    Get PDF
    In this book, we present a dozen state of the art developments for ultrasound imaging, for example, hardware implementation, transducer, beamforming, signal processing, measurement of elasticity and diagnosis. The editors would like to thank all the chapter authors, who focused on the publication of this book
    corecore