5,528 research outputs found

    A general magnetic-energy-based torque estimator: validation via a permanent-magnet motor drive

    Get PDF
    This paper describes the use of the current–flux-linkage (ipsii{-}psi ) diagram to validate the performance of a general magnetic-energy-based torque estimator. An early step in the torque estimation is the use of controller duty cycles to reconstruct the average phase-voltage waveform during each pulsewidth-modulation (PWM) switching period. Samples over the fundamental period are recorded for the estimation of the average torque. The fundamental period may not be an exact multiple of the sample time. For low speed, the reconstructed voltage requires additional compensation for inverter-device losses. Experimental validation of this reconstructed waveform with the actual PWM phase-voltage waveform is impossible due to the fact that one is PWM in nature and the other is the average value during the PWM period. A solution to this is to determine the phase flux-linkage using each waveform and then plot the resultant ipsii{-}psi loops. The torque estimation is based on instantaneous measurements and can therefore be applied to any electrical machine. This paper includes test results for a three-phase interior permanent-magnet brushless ac motor operating with both sinusoidal and nonsinusoidal current waveforms

    Direct torque control of brushless DC drives with reduced torque ripple

    Get PDF
    The application of direct torque control (DTC) to brushless ac drives has been investigated extensively. This paper describes its application to brushless dc drives, and highlights the essential differences in its implementation, as regards torque estimation and the representation of the inverter voltage space vectors. Simulated and experimental results are presented, and it is shown that, compared with conventional current control, DTC results in reduced torque ripple and a faster dynamic response

    FPGA-based implementation of the back-EMF symmetric-threshold-tracking sensorless commutation method for brushless DC-machines

    Get PDF
    The operation of brushless DC permanent-magnet machines requires information of the rotor position to steer the semiconductor switches of the power-supply module which is commonly referred to as Brushless Commutation. Different sensorless techniques have been proposed to estimate the rotor position using current and voltage measurements of the machine. Detection of the back-electromotive force (EMF) zero-crossing moments is one of the methods most used to achieve sensorless control by predicting the commutation moments. Most of the techniques based on this phenomenon have the inherit disadvantage of an indirect detection of commutation moments. This is the result of the commutation moment occurring 30 electrical degrees after the zero-crossing of the induced back-emf in the unexcited phase. Often, the time difference between the zero crossing of the back-emf and the optimal current commutation is assumed constant. This assumption can be valid for steady-state operation, however a varying time difference should be taken into account during transient operation of the BLDC machine. This uncertainty degrades the performance of the drive during transients. To overcome this problem which improves the performance while keeping the simplicity of the back-emf zero-crossing detection method an enhancement is proposed. The proposed sensorless method operates parameterless in a way it uses none of the brushless dc-machine parameters. In this paper different aspects of experimental implementation of the new method as well as various aspects of the FPGA programming are discussed. Proposed control method is implemented within a Xilinx Spartan 3E XC3S500E board

    Assessment of torque components in brushless permanent-magnet machines through numerical analysis of the electromagnetic field

    Get PDF
    For the calculation of torque in brushless (BL) alternating current motors a local method is proposed, based on the Maxwell stress theory and the filtered contributions due to the harmonics of the magnetic vector potential in the motor air gap. By considering the space fundamental field only, the method can efficiently estimate the average synchronous torque for a variety or motor topologies, including concentrated winding designs. For BL direct current motor analysis a global method is introduced, based on the virtual work principle expressed in terms of energy components in various motor regions. The method leads to simplifications in the average torque calculation and enables the direct identification of the cogging and ripple components. The mathematical procedures have been validated against experiments and other numerical techniques

    Optimal design of switched reluctance motors

    Get PDF
    The fundamental theory of the switched reluctance motor is presented with a number of new equations. It is used to show how the practical development of a design calculation should proceed, and this leads to a discussion of physical characteristics required to achieve satisfactory performance and to reduce acoustic noise. The paper makes a few generic observations on the characteristics of successful products that use switched reluctance motors. It is written at a basic engineering level and makes no attempt to apply sophisticated optimization theory

    High-frequency issues using rotating voltage injections intended for position self-sensing

    Get PDF
    The rotor position is required in many control schemes in electrical drives. Replacing position sensors by machine self-sensing estimators increases reliability and reduces cost. Solutions based on tracking magnetic anisotropies through the monitoring of the incremental inductance variations are efficient at low-speed and standstill operations. This inductance can be estimated by measuring the response to the injection of high-frequency signals. In general however, the selection of the optimal frequency is not addressed thoroughly. In this paper, we propose discrete-time operations based on a rotating voltage injection at frequencies up to one third of the sampling frequency used by the digital controller. The impact on the rotation-drive, the computational requirement, the robustness and the effect of the resistance on the position estimation are analyzed regarding the signal frequency

    Improved transistor-controlled and commutated brushless DC motors for electric vehicle propulsion

    Get PDF
    The development, design, construction, and testing processes of two electronically (transistor) controlled and commutated permanent magnet brushless dc machine systems, for propulsion of electric vehicles are detailed. One machine system was designed and constructed using samarium cobalt for permanent magnets, which supply the rotor (field) excitation. Meanwhile, the other machine system was designed and constructed with strontium ferrite permanent magnets as the source of rotor (field) excitation. These machine systems were designed for continuous rated power output of 15 hp (11.2 kw), and a peak one minute rated power output of 35 hp (26.1 kw). Both power ratings are for a rated voltage of 115 volts dc, assuming a voltage drop in the source (battery) of about 5 volts. That is, an internal source voltage of 120 volts dc. Machine-power conditioner system computer-aided simulations were used extensively in the design process. These simulations relied heavily on the magnetic field analysis in these machines using the method of finite elements, as well as methods of modeling of the machine power conditioner system dynamic interaction. These simulation processes are detailed. Testing revealed that typical machine system efficiencies at 15 hp (11.2 kw) were about 88% and 84% for the samarium cobalt and strontium ferrite based machine systems, respectively. Both systems met the peak one minute rating of 35 hp

    Fault-Tolerant Capability and Torque-Speed Measurements of Permanent Magnet Brushless AC Machines

    Get PDF
    In this paper, the fault-tolerant capability in terms of inductance profile of a dual-stator permanent magnet brushless AC machine is presented. Similarly, its power-speed and torque-speed characteristics are also predicted. Special reference is made to the impact of different rotor pole numbers. A 2D-finite element analysis (FEA) procedure is adopted in this work, and the cross-coupling effect of the machine inductances owing to the influence of direct-axis and quadrature-axis currents is also taken into consideration. The results show that, the investigated machine having odd number of rotor poles would exhibit better fault-tolerant capability compared to their counterparts with even number of rotor poles. Further, the machine having 6-stator slots and 13-rotor poles i.e. 6Slots-13P machine has the greatest field-weakening potential owing to its high full-speed to rated speed relation. The studies also show that, the investigated machines have negligible reluctance torque due to their basically unity saliency ratios obtained from the machines’ almost similar quadrature-axis inductance, Lq, and direct-axis inductance, Ld, values.Keywords: Direct-axis, Quadrature-axis, Inductance, Power, Speed, Torque, AC machines, Permanent magnet

    The integration of input filters in electrical drives

    Get PDF
    PhD ThesisThe integration of passive components such as inductors and capacitors has gained significant popularity in integrated drive research, and future power electronics systems will require more integrated and standardised packages. These give rise to better power density and improved performance. However, packaging techniques and passive components have been considered a technological barrier which is limiting advances in power electronics. The focus on size reduction should be turned towards the passive components, such as converter chokes, DC-link capacitors and electromagnetic interference (EMI) filters, and achieving greater power density depends on innovative integration concepts, flexibility in structures and extended operating temperature ranges while system integration and modularity are not mutually exclusive. This research considers the possibility of integrating input power filter components into electric machines. Particular attention is paid to the integration of electromagnetic line filter inductors to give better utilisation of the motor volume and envelope. This can be achieved by sharing the machine’s magnetic circuit. An LCL line filter has been chosen to be integrated with a gridconnected permanent magnet synchronous machine. Machines have been proposed in this study for low speed (3000 RPM) and high speed (25000 RPM) operation. The two machines have similar dimensions, but the low-speed machine is less challenging in terms of losses and filter integration, so attention is directed more to the high-speed machine. Both are supplied with low- and high-power drives at power ratings of 4.5 kW and 38 kW respectively. Several novel techniques have been investigated to integrate filter inductors into the electrical machines to produce a single mechanically packaged unit without significant increases in size and losses. Different approaches have been simulated using finite element analysis (FEA) to assess the effectiveness of the integration of passives within the machine structure. Each design has been iteratively optimised to determine the best mass of copper and core for the integrated filter inductors, targeting parity in power density when compared to traditional separate packages. The research demonstrates that an approach utilising a double-slot stator machine (named the integrated double slot (IDS) machine) with input filters wound into the outermost slots is the most appropriate choice in terms of achieving higher power density. The integrated filter inductors mimic the electromagnetic behaviour of the discrete industrially packaged inductors but with a volume reduction of 87.6%. A prototype of the IDS machine design of a 38 kW, 25000 RPM, including filter inductors was manufactured and testedthe General Electricity Company of Libya (GECOL), the Engineering and Physical Sciences Research Council (EPSRC), and the Engineering Doctorate scheme at Newcastle University

    Hybrid modeling techniques embracing permanent-magnet-biased salient machines

    Get PDF
    corecore