113 research outputs found

    Stability of Mina v2 for Robot-Assisted Balance and Locomotion

    Get PDF
    The assessment of the risk of falling during robot-assisted locomotion is critical for gait control and operator safety, but has not yet been addressed through a systematic and quantitative approach. In this study, the balance stability of Mina v2, a recently developed powered lower-limb robotic exoskeleton, is evaluated using an algorithmic framework based on center of mass (COM)- and joint-space dynamics. The equivalent mechanical model of the combined human-exoskeleton system in the sagittal plane is established and used for balance stability analysis. The properties of the Linear Linkage Actuator, which is custom-designed for Mina v2, are analyzed to obtain mathematical models of torque-velocity limits, and are implemented as constraint functions in the optimization formulation. For given feet configurations of the robotic exoskeleton during flat ground walking, the algorithm evaluates the maximum allowable COM velocity perturbations along the fore-aft directions at each COM position of the system. The resulting velocity extrema form the contact-specific balance stability boundaries (BSBs) of the combined system in the COM state space, which represent the thresholds between balanced and unbalanced states for given contact configurations. The BSBs are obtained for the operation of Mina v2 without crutches, thus quantifying Mina v2's capability of maintaining balance through the support of the leg(s). Stability boundaries in single and double leg supports are used to analyze the robot's stability performance during flat ground walking experiments, and provide design and control implications for future development of crutch-less robotic exoskeletons

    Assistive mobility devices focusing on smart walkers : classification and review

    Get PDF
    In an aging society it is extremely important to develop devices, which can support and aid the elderly in their daily life. This demands means and tools that extend independent living and promote improved health. Thus, the goal of this article is to review the state of the art in the robotic technology for mobility assistive devices for people with mobility disabilities. The important role that robotics can play in mobility assistive devices is presented, as well as the identification and survey of mobility assistive devices subsystems with a particular focus on the walkers technology. The advances in the walkers’ field have been enormous and have shown a great potential on helping people with mobility disabilities. Thus it is presented a review of the available literature of walkers and are discussed major advances that have been made and limitations to be overcome

    Automatic Setting Procedure for Exoskeleton-Assisted Overground Gait: Proof of Concept on Stroke Population

    Get PDF
    Stroke-related locomotor impairments are often associated with abnormal timing and intensity of recruitment of the affected and non-affected lower limb muscles. Restoring the proper lower limbs muscles activation is a key factor to facilitate recovery of gait capacity and performance, and to reduce maladaptive plasticity. Ekso is a wearable powered exoskeleton robot able to support over-ground gait training. The user controls the exoskeleton by triggering each single step during the gait cycle. The fine-tuning of the exoskeleton control system is crucial-it is set according to the residual functional abilities of the patient, and it needs to ensure lower limbs powered gait to be the most physiological as possible. This work focuses on the definition of an automatic calibration procedure able to detect the best Ekso setting for each patient. EMG activity has been recorded from Tibialis Anterior, Soleus, Rectus Femoris, and Semitendinosus muscles in a group of 7 healthy controls and 13 neurological patients. EMG signals have been processed so to obtain muscles activation patterns. The mean muscular activation pattern derived from the controls cohort has been set as reference. The developed automatic calibration procedure requires the patient to perform overground walking trials supported by the exoskeleton while changing parameters setting. The Gait Metric index is calculated for each trial, where the closer the performance is to the normative muscular activation pattern, in terms of both relative amplitude and timing, the higher the Gait Metric index is. The trial with the best Gait Metric index corresponds to the best parameters set. It has to be noted that the automatic computational calibration procedure is based on the same number of overground walking trials, and the same experimental set-up as in the current manual calibration procedure. The proposed approach allows supporting the rehabilitation team in the setting procedure. It has been demonstrated to be robust, and to be in agreement with the current gold standard (i.e., manual calibration performed by an expert engineer). The use of a graphical user interface is a promising tool for the effective use of an automatic procedure in a clinical context

    Instrumentation and validation of a robotic cane for transportation and fall prevention in patients with affected mobility

    Get PDF
    Dissertação de mestrado integrado em Engenharia Física, (especialização em Dispositivos, Microssistemas e Nanotecnologias)O ato de andar é conhecido por ser a forma primitiva de locomoção do ser humano, sendo que este traz muitos benefícios que motivam um estilo de vida saudável e ativo. No entanto, há condições de saúde que dificultam a realização da marcha, o que por consequência pode resultar num agravamento da saúde, e adicionalmente, levar a um maior risco de quedas. Nesse sentido, o desenvolvimento de um sistema de deteção e prevenção de quedas, integrado num dispositivo auxiliar de marcha, seria essencial para reduzir estes eventos de quedas e melhorar a qualidade de vida das pessoas. Para ultrapassar estas necessidades e limitações, esta dissertação tem como objetivo validar e instrumentar uma bengala robótica, denominada Anti-fall Robotic Cane (ARCane), concebida para incorporar um sistema de deteção de quedas e um mecanismo de atuação que possibilite a prevenção de quedas, ao mesmo tempo que assiste a marcha. Para esse fim, foi realizada uma revisão do estado da arte em bengalas robóticas para adquirir um conhecimento amplo e aprofundado dos componentes, mecanismos e estratégias utilizadas, bem como os protocolos experimentais, principais resultados, limitações e desafios em dispositivos existentes. Numa primeira fase, foi estipulado o objetivo de: (i) adaptar a missão do produto; (ii) estudar as necessidades do consumidor; e (iii) atualizar as especificações alvo da ARCane, continuação do trabalho de equipa, para obter um produto com design e engenharia compatível com o mercado. Foi depois estabelecida a arquitetura de hardware e discutidos os componentes a ser instrumentados na ARCane. Em seguida foram realizados testes de interoperabilidade a fim de validar o funcionamento singular e coletivo dos componentes. Relativamente ao controlo de movimento, foi desenvolvido um sistema inovador, de baixo custo e intuitivo, capaz de detetar a intenção do movimento e de reconhecer as fases da marcha do utilizador. Esta implementação foi validada com seis voluntários saudáveis que realizaram testes de marcha com a ARCane para testar sua operabilidade num ambiente de contexto real. Obteve-se uma precisão de 97% e de 90% em relação à deteção da intenção de movimento e ao reconhecimento da fase da marcha do utilizador. Por fim, foi projetado um método de deteção de quedas e mecanismo de prevenção de quedas para futura implementação na ARCane. Foi ainda proposta uma melhoria do método de deteção de quedas, de modo a superar as limitações associadas, bem como a proposta de dispositivos de deteção a serem implementados na ARCane para obter um sistema completo de deteção de quedas.The act of walking is known to be the primitive form of the human being, and it brings many benefits that motivate a healthy and active lifestyle. However, there are health conditions that make walking difficult, which, consequently, can result in worse health and, in addition, lead to a greater risk of falls. Thus, the development of a fall detection and prevention system integrated with a walking aid would be essential to reduce these fall events and improve people quality of life. To overcome these needs and limitations, this dissertation aims to validate and instrument a cane-type robot, called Anti-fall Robotic Cane (ARCane), designed to incorporate a fall detection system and an actuation mechanism that allow the prevention of falls, while assisting the gait. Therefore, a State-of-the-Art review concerning robotic canes was carried out to acquire a broad and in-depth knowledge of the used components, mechanisms and strategies, as well as the experimental protocols, main results, limitations and challenges on existing devices. On a first stage, it was set an objective to (i) enhance the product's mission statement; (ii) study the consumer needs; and (iii) update the target specifications of the ARCane, extending teamwork, to obtain a product with a market-compatible design and engineering that meets the needs and desires of the ARCane users. It was then established the hardware architecture of the ARCane and discussed the electronic components that will instrument the control, sensory, actuator and power units, being afterwards subjected to interoperability tests to validate the singular and collective functioning of cane components altogether. Regarding the motion control of robotic canes, an innovative, cost-effective and intuitive motion control system was developed, providing user movement intention recognition, and identification of the user's gait phases. This implementation was validated with six healthy volunteers who carried out gait trials with the ARCane, in order to test its operability in a real context environment. An accuracy of 97% was achieved for user motion intention recognition and 90% for user gait phase recognition, using the proposed motion control system. Finally, it was idealized a fall detection method and fall prevention mechanism for a future implementation in the ARCane, based on methods applied to robotic canes in the literature. It was also proposed an improvement of the fall detection method in order to overcome its associated limitations, as well as detection devices to be implemented into the ARCane to achieve a complete fall detection system

    Safe Haptics-enabled Patient-Robot Interaction for Robotic and Telerobotic Rehabilitation of Neuromuscular Disorders: Control Design and Analysis

    Get PDF
    Motivation: Current statistics show that the population of seniors and the incidence rate of age-related neuromuscular disorders are rapidly increasing worldwide. Improving medical care is likely to increase the survival rate but will result in even more patients in need of Assistive, Rehabilitation and Assessment (ARA) services for extended periods which will place a significant burden on the world\u27s healthcare systems. In many cases, the only alternative is limited and often delayed outpatient therapy. The situation will be worse for patients in remote areas. One potential solution is to develop technologies that provide efficient and safe means of in-hospital and in-home kinesthetic rehabilitation. In this regard, Haptics-enabled Interactive Robotic Neurorehabilitation (HIRN) systems have been developed. Existing Challenges: Although there are specific advantages with the use of HIRN technologies, there still exist several technical and control challenges, e.g., (a) absence of direct interactive physical interaction between therapists and patients; (b) questionable adaptability and flexibility considering the sensorimotor needs of patients; (c) limited accessibility in remote areas; and (d) guaranteeing patient-robot interaction safety while maximizing system transparency, especially when high control effort is needed for severely disabled patients, when the robot is to be used in a patient\u27s home or when the patient experiences involuntary movements. These challenges have provided the motivation for this research. Research Statement: In this project, a novel haptics-enabled telerobotic rehabilitation framework is designed, analyzed and implemented that can be used as a new paradigm for delivering motor therapy which gives therapists direct kinesthetic supervision over the robotic rehabilitation procedure. The system also allows for kinesthetic remote and ultimately in-home rehabilitation. To guarantee interaction safety while maximizing the performance of the system, a new framework for designing stabilizing controllers is developed initially based on small-gain theory and then completed using strong passivity theory. The proposed control framework takes into account knowledge about the variable biomechanical capabilities of the patient\u27s limb(s) in absorbing interaction forces and mechanical energy. The technique is generalized for use for classical rehabilitation robotic systems to realize patient-robot interaction safety while enhancing performance. In the next step, the proposed telerobotic system is studied as a modality of training for classical HIRN systems. The goal is to first model and then regenerate the prescribed kinesthetic supervision of an expert therapist. To broaden the population of patients who can use the technology and HIRN systems, a new control strategy is designed for patients experiencing involuntary movements. As the last step, the outcomes of the proposed theoretical and technological developments are translated to designing assistive mechatronic tools for patients with force and motion control deficits. This study shows that proper augmentation of haptic inputs can not only enhance the transparency and safety of robotic and telerobotic rehabilitation systems, but it can also assist patients with force and motion control deficiencies

    Engineering a robotic exoskeleton for space suit simulation

    Get PDF
    Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, 2013.Cataloged from PDF version of thesis.Includes bibliographical references (pages 177-181).Novel methods for assessing space suit designs and human performance capabilities are needed as NASA prepares for manned missions beyond low Earth orbit. Current human performance tests and training are conducted in space suits that are heavy and expensive, characteristics that constrain possible testing environments and reduce suit availability to researchers. Space suit mock-ups used in planetary exploration simulations are light and relatively inexpensive but do not accurately simulate the joint stiffness inherent to space suits, a key factor impacting extravehicular activity performance. The MIT Man-Vehicle Laboratory and Aurora Flight Sciences designed and built an actively controlled exoskeleton for space suit simulation called the Extravehicular Activity Space Suit Simulator (EVA S3), which can be programmed to simulate the joint torques recorded from various space suits. The goal of this research is to create a simulator that is lighter and cheaper than a traditional space suit so that it can be used in a variety of testing and training environments. The EVA S3 employs pneumatic actuators to vary joint stiffness and a pre-programmed controller to allow the experimenter to apply torque profiles to mimic various space suit designs in the field. The focus of this thesis is the design, construction, integration, and testing of the hip joint and backpack for the EVA S3. The final designs of the other joints are also described. Results from robotic testing to validate the mechanical design and control system are discussed along with the planned improvements for the next iteration of the EVA S3. The fianl EVA S3 consists of a metal and composite exoskeleton frame with pneumatic actuators that control the resistance of motion in the ankle, knee, and hip joints, and an upper body brace that resists shoulder and elbow motions with passive spring elements. The EVA S3 is lighter (26 kg excluding the tethered components) and less expensive (under $600,000 including research, design, and personnel) than a modem space suit. Design adjustments and control system improvements are still needed to achieve a desired space suit torque simulation fidelity within 10% root-mean-square error.by Forrest Edward Meyen.S.M

    Rehabilitation prototype to improves mobility of acute rotator cuff injury

    Get PDF
    The deterioration of the components of the rotator cuff is one of the most frequent causes of musculoskeletal pain and disability in the world. The conditions of the rotator cuff increase with the passage of time, since they have a direct relationship with a process of deterioration rather than with a traumatic event. In order to decrease pain and recover shoulder movement, patients are usually treated by regular sessions with a physiotherapist. However, more sessions are required than those stipulated to fully obtain recover mobility. This paper present the development of portable prototype to rehabilitate acute rotator cuff injure, designed from biomechanical analysis and ranges the kinematics and dynamics articulated in the present design determine important requirements in obtaining greater functionality of the prototype and with it, allows the identification of sensors and actuators for executing two types of specific movements: flexion / extension and external / internal rotation by means of a soft rehabilitation robot

    Analysis and Characterization of Embroidered Textile Strain Sensors for Use in Wearable Mechatronic Devices

    Get PDF
    Stroke and musculoskeletal disorders affect hundreds of millions of people around the world. To aid in the recovery process of people affected by these conditions, the use of wearable mechatronic devices has been proposed during traditional rehabilitation therapies. However, factor such as rigidity, increased weight, and overall bulkiness have hindered the adoption of these devices in a clinical setting. Therefore, alternative solutions in the form of soft wearable mechatronic devices have been proposed recently. This is due to these devices being lightweight and comfortable, and compliant, which makes them easier to conform to the human body. To achieve such compliance, high emphasis has been placed on the development of soft sensing mechanisms, as they are in charge of collecting information from the device, the environment and user. Among these sensing mechanisms, force and motion sensors have been extensively studied, as they are the simplest to integrate in wearable mechatronic devices. However, the majority of these sensors have been developed using soft materials that are not breathable and can cause skin irritations due to the materials used to fabricate them. For these reasons, textile sensors have been proposed as an alternative. Among these textile solutions, embroidered sensors have shown great potential, as they are relatively simple to manufacture and have high scalability characteristics. Unfortunately, embroidered sensors have the disadvantage of not being stretchable, which is one of the many characteristics of motion and force sensors. To address these issues, this thesis focuses on the design, development, characterization, and performance assessment of embroidered textile strain sensors. To this end, a framework for the development of embroidered textile strain sensors was proposed. This framework included all the necessary steps to design and fabricate these sensors. To achieve the required stretchability of embroidered sensors, a set of customizable parameters were included within this framework. Then, following the guidelines of the proposed framework, a novel embroidered strain sensor was created using a honeycomb pattern. This pattern had two main purposes: a distribution of the axial forces across the walls of the honeycomb design to protect the conductive thread; and the addition of stretchiness to the embroidered sensor. Sensors created using this pattern were embroidered onto an elastic band and then attached to a strain compensation system to increase the stretchability of the sensor further. After 50 stretching cycles, sensors showed good linearity, an average gauge factor of 0.24, an average hysteresis of 36.85% and up to 55.56% working range. This demonstrated the ability of the embroidered sensor to work as a strain sensor, without showing signs of damage and without showing signs of deformation. Lastly, a series of embroidered sensors were fabricated using a Kirigami design. These sensors were created to measure forces under dynamic conditions. Before testing, these sensors were attached to a strain compensation mechanism, which in turn was attached to a force sensing device that served as ground truth for the data collected by the embroidered sensors. The embroidered sensors were tested under three different speed profiles: slow speed, medium speed, and high speed. On each speed profile, each sensor showed high linearity, a low hysteretic behaviour, and relatively good repeatability. These results established the capabilities of the embroidered strain sensors as force sensors that could be used inside soft wearable mechatronic devices

    Robust Impedance Control of a Four Degree of Freedom Exercise Robot

    Get PDF
    The CSU 4OptimX exercise robot provides a platform for future research into advanced exercise and rehabilitation. The robot and its control system will autonomously modify reference trajectories and impedances on the basis of an optimization criterion and physiological feedback. To achieve this goal, a robust impedance control system with trajectory tracking must be implemented as the foundational control scheme. Two control laws will be compared, sliding mode and H-infinity control. The above robust control laws are combined with underlying impedance control laws to overcome uncertain plant model parameters and disturbance anomalies affecting the input signal. The sliding mode control law is synthesized based on a nominal plant model due to its inherent nature of overcoming unspecified, un-modeled dynamics and disturbances. Implementation of the H-infinity control law uses weights as well as the nominal plant, a structured parametric uncertainty model of the plant, and a model with multiplicative uncertainty. The performance and practicality of each controller is discussed as well as the challenges associated with attempts to implement controllers successfully onto the robot. The findings of this thesis indicate that the closed loop controller with sliding mode is the superior control scheme due to its abilities to counter non-linearities. It is chosen as the platform control scheme. The 2 out of 3 H-infinity controllers performed well in simulation but only one was able to successfully control the robot. Challenges associated with H-infinity control implementation toward impedance control include determining proper weight shapes that balance performance and practicality. This challenge is a starting point for future research into general weight shape determination for H-infinity robust impedance control

    Applications of EMG in Clinical and Sports Medicine

    Get PDF
    This second of two volumes on EMG (Electromyography) covers a wide range of clinical applications, as a complement to the methods discussed in volume 1. Topics range from gait and vibration analysis, through posture and falls prevention, to biofeedback in the treatment of neurologic swallowing impairment. The volume includes sections on back care, sports and performance medicine, gynecology/urology and orofacial function. Authors describe the procedures for their experimental studies with detailed and clear illustrations and references to the literature. The limitations of SEMG measures and methods for careful analysis are discussed. This broad compilation of articles discussing the use of EMG in both clinical and research applications demonstrates the utility of the method as a tool in a wide variety of disciplines and clinical fields