142 research outputs found

    A Micro Mobile Robot with Suction Cups in the Abdominal Cavity for NOTES

    Get PDF

    Advanced Bionic Attachment Equipment Inspired by the Attachment Performance of Aquatic Organisms: A Review

    Get PDF
    In nature, aquatic organisms have evolved various attachment systems, and their attachment ability has become a specific and mysterious survival skill for them. Therefore, it is significant to study and use their unique attachment surfaces and outstanding attachment characteristics for reference and develop new attachment equipment with excellent performance. Based on this, in this review, the unique non-smooth surface morphologies of their suction cups are classified and the key roles of these special surface morphologies in the attachment process are introduced in detail. The recent research on the attachment capacity of aquatic suction cups and other related attachment studies are described. Emphatically, the research progress of advanced bionic attachment equipment and technology in recent years, including attachment robots, flexible grasping manipulators, suction cup accessories, micro-suction cup patches, etc., is summarized. Finally, the existing problems and challenges in the field of biomimetic attachment are analyzed, and the focus and direction of biomimetic attachment research in the future are pointed out

    Track-Guided Ultrasound Scanning for Tumour Margins Outlining in Robot-Assisted Partial Nephrectomy

    Get PDF
    Robot-Assisted Partial Nephrectomy (RAPN) is a medical procedure in which part of a kidney is removed, typically because of the presence of a tumour. RAPN is the second most diffused robotically assisted surgical procedure worldwide after prostatectomy [1]. The advantages of this robot-assisted procedure are detailed in [2], and in [3] it is argued that RAPN can be used in place of open surgery or total nephrectomy in some complex renal tumour cases. The RAPN procedure is thoroughly described in [4]. Methods used for the identification of the tumour include pre-operative Computer Tomography (CT) scans, Magnetic Resonance (MR) imaging and intraoperative Ultrasound (US) scans. The use of drop-in US probes for RAPN procedures is widely recognized as the golden standard for the intraoperative detection and margins outlining of the mass targeted. In [5] the authors show that the use of US dropin probes guided by robotic laparoscopic tools rather than standard laparoscopic tool is beneficial for the surgeon as it significantly increases the dexterity, hence, the field of view of the system

    Design, analysis and trajectory tracking control of underactuated mobile capsule robots.

    Get PDF
    The research on capsule robots (capsubots) has received attraction in recent years because of their compactness, simple structure and their potential use in medical diagnosis (e.g. capsule endoscopy), treatment and surgical assistance. The medical diagnostic capability of a capsule endoscope - which moves with the aid of visceral peristalsis - in the GI (gastro-intestinal) tract can be improved by adding propulsion to it e.g. legged, magnetic or capsubot-type propulsion. Driven by the above needs this thesis presents the design, analysis, trajectory tracking control and implementation of underactuated mobile capsule robots. These capsule robots can be modified and used in in-vivo medical applications. Researches on the capsubottype underactuated system focus on the stabilization of the robot and tracking the actuated configuration. However trajectory tracking control of an unactuated configuration (i.e. the robotmotion)was not considered in the literature though it is the primary requirement of any mobile robot and also crucial for many applications such as in-vivo inspection. Trajectory tracking control for this class of underactuated mechanical systems is still an open issue. This thesis presents a strategy to solve this issue. This thesis presents three robots namely a one-dimensional (1D) capsule robot, a 2D capsule robot and a 2D hybrid capsule robot with incremental capability. Two new acceleration profiles (utroque and contrarium) for the inner mass (IM) - internal moving part of the capsule robot - are proposed, analysed and implemented for the motion generation of the capsule robots. This thesis proposes a two-stage control strategy for the motion control of an underactuated capsule robot. A segment-wise trajectory tracking algorithm is developed for the 1D capsule robot. Theoretical analysis of the algorithm is presented and simulation is performed in the Matlab/Simulink environment based on the theoretical analysis. The algorithm is implemented in the developed capsule robot, the experimentation is performed and the results are critically analyzed. A trajectory tracking control algorithm combining segment-wise and behaviour-based control is proposed for the 2D capsule robot. Detailed theoretical analysis is presented and the simulation is performed to investigate the robustness of the trajectory tracking algorithm to friction uncertainties. A 2D capsule robot prototype is developed and the experimentation is performed. A novel 2D hybrid robot with four modes of operation - legless motion mode, legged motion mode, hybrid motion mode and anchoring mode - is also designed which uses one set of actuators in all operating modes. The theoretical analysis, modelling and simulation is performed. This thesis demonstrates effective ways of propulsion for in-vivo applications. The outer-shape of the 1D and 2D capsule robots can be customized according to the requirement of the applications, as the propulsion mechanisms are completely internal. These robots are also hermetically sealable (enclosed) which is a safety feature for the in-vivo robots. This thesis addresses the trajectory tracking control of the capsubot-type robot for the first time. During the experimentation the 1D robot prototype tracks the desired position trajectory with some error (relative mean absolute error: 16%). The trajectory tracking performance for the 2D capsubot improves as the segment time decreases whereas tracking performance declines as the friction uncertainty increases. The theoretical analysis, simulation and experimental results validate the proposed acceleration profiles and trajectory tracking control algorithms. The designed hybrid robot combines the best aspects of the legless and legged motions. The hybrid robot is capable of stopping in a suspected region and remain stationary for a prolonged observation for the in-vivo applications while withstanding the visceral peristalsis

    An overview of robotics and autonomous systems for harsh environments

    Get PDF
    Across a wide range of industries and applications, robotics and autonomous systems can fulfil the crucial and challenging tasks such as inspection, exploration, monitoring, drilling, sampling and mapping in areas of scientific discovery, disaster prevention, human rescue and infrastructure management, etc. However, in many situations, the associated environment is either too dangerous or inaccessible to humans. Hence, a wide range of robots have been developed and deployed to replace or aid humans in these activities. A look at these harsh environment applications of robotics demonstrate the diversity of technologies developed. This paper reviews some key application areas of robotics that involve interactions with harsh environments (such as search and rescue, space exploration, and deep-sea operations), gives an overview of the developed technologies and provides a discussion of the key trends and future directions common to many of these areas
    • …
    corecore