220 research outputs found

    Magnetohydrodynamics in microchannels and adhesion properties of nanoporous alumina films

    Full text link
    In the first part of this dissertation, RedOx-based magnetohydrodynamic (MHD) flows in three-dimensional (3D) microfluidic channels are investigated theoretically with a coupled mathematical model consisting of the Nernst-Planck equations for the concentrations of ionic species, the local electroneutrality condition of the electric potential, and the Navier-Stokes equations for the flow field. The induced currents and flow rates in 3D planar channels are compared with the experimental data obtained from the literature and those obtained from the previous two-dimensional mathematical model. Then a new approximate closed form solution for the velocity profile of steady incompressible MHD flows in a rectangular micro-channel is proposed. It can be used to optimize the dimensions of the channel and to determine the magnitudes and polarities of the prescribed currents in MHD networks so as to achieve the desired flow patterns and flow rates; In the second part of the dissertation, the adhesive properties of thin nanoporous alumina templates are investigated. Such templates are important in fabricating an array of nanopores that will be used in the Lab on a Chip technology

    A Customer Programmable Microfluidic System

    Get PDF
    Microfluidics is both a science and a technology offering great and perhaps even revolutionary capabilities to impact the society in the future. However, due to the scaling effects there are unknown phenomena and technology barriers about fluidics in microchannel, material properties in microscale and interactions with fluids are still missing. A systematic investigation has been performed aiming to develop A Customer Programmable Microfluidic System . This innovative Polydimethylsiloxane (PDMS)-based microfluidic system provides a bio-compatible platform for bio-analysis systems such as Lab-on-a-chip, micro-total-analysis system and biosensors as well as the applications such as micromirrors. The system consists of an array of microfluidic devices and each device containing a multilayer microvalve. The microvalve uses a thermal pneumatic actuation method to switch and/or control the fluid flow in the integrated microchannels. It provides a means to isolate samples of interest and channel them from one location of the system to another based on needs of realizing the customers\u27 desired functions. Along with the fluid flow control properties, the system was developed and tested as an array of micromirrors. An aluminum layer is embedded into the PDMS membrane. The metal was patterned as a network to increase the reflectivity of the membrane, which inherits the deformation of the membrane as a mirror. The deformable mirror is a key element in the adaptive optics. The proposed system utilizes the extraordinary flexibility of PDMS and the addressable control to manipulate the phase of a propagating optical wave front, which in turn can increase the performance of the adaptive optics. Polydimethylsiloxane (PDMS) has been widely used in microfabrication for microfluidic systems. However, few attentions were paid in the past to mechanical properties of PDMS. Importantly there is no report on influences of microfabrication processes which normally involve chemical reactors and biologically reaction processes. A comprehensive study was made in this work to study fundamental issues such as scaling law effects on PDMS properties, chemical emersion and temperature effects on mechanical properties of PDMS, PDMS compositions and resultant properties, as well as bonding strength, etc. Results achieved from this work will provide foundation of future developments of microfluidics utilizing PDMS

    Microfluidic DNA amplification - a review

    Get PDF
    The application of microfluidic devices for DNA amplification has recently been extensively studied. Here, we review the important development of microfluidic polymerase chain reaction (PCR) devices and discuss the underlying physical principles for the optimal design and operation of the device. In particular, we focus on continuous-flow microfluidic PCR on-chip, which can be readily implemented as an integrated function of a micro-total-analysis system. To overcome sample carryover contamination and surface adsorption associated with microfluidic PCR, microdroplet technology has recently been utilized to perform PCR in droplets, which can eliminate the synthesis of short chimeric products, shorten thermal-cycling time, and offers great potential for single DNA molecule and single-cell amplification. The work on chip-based PCR in droplets is highlighted

    Iris segmentation

    Get PDF
    The quality of eye image data become degraded particularly when the image is taken in the non-cooperative acquisition environment such as under visible wavelength illumination. Consequently, this environmental condition may lead to noisy eye images, incorrect localization of limbic and pupillary boundaries and eventually degrade the performance of iris recognition system. Hence, this study has compared several segmentation methods to address the abovementioned issues. The results show that Circular Hough transform method is the best segmentation method with the best overall accuracy, error rate and decidability index that more tolerant to β€˜noise’ such as reflection

    Nonreciprocity Applications in Acoustics and Microfluidic Systems

    Get PDF
    Breaking reciprocity in linear acoustic systems and designing a novel actuator for the nonreciprocal valveless pumps are studied in this dissertation. The first part was started by deriving the acoustic governing equations in a moving wave propagation medium. It was shown thatthe Coriolis acceleration term appears ina cross-product term with the wave vector. It means the main reason for breaking reciprocity in the circular fluid flow is the Coriolis acceleration term. Finally, the governing equations were solved numerically by COMSOL Multiphysics software. Moreover, Green`s second identity was used as a complimentary method to prove breaking reciprocityin such a system with moving medium. It is concluded that the non-reciprocity is magnified by increasing the angular velocity of the fluid system. The second part of this thesis is about achieving non-reciprocity utilizing the arrangement of a nozzle and diffuser as the inlet and outlet ports. This part’s goal is to design a novel flexible actuator design for a valveless pump. The actuation mechanism which is novel in its own term, uses liquid metal called galinstan, a non-magnetic but electrically conducting alloy. In the designed device, an alternating current (AC) is applied onto a microchannel filled with galinstan. This device is placed between two permanent magnets with opposing poles. Due to the Lorentz force law, there will be radial in-plane forces on the polymeric flexible substrate. These in-plane forces radially contract and expand the circular diaphragm to provide an upward and downward out of plane bending moment, which causes an oscillatory reciprocating movement similar to a piezoelectric actuator`s movement. Compared to the traditional piezo electric materials such as Lead Zirconate Titanate (PZT), this actuator has numerous advantages such as being flexible, having the ability to be scaled down, being formed as an integrated structure, and being fabricated by a considerably simple process. The prototype of the pump could be fabricated easily with Platinum Silicone rubber and some low-cost 3D printed elements. Although the prototype has been fabricated in a relatively large size, it is considered as a proper conceptual model representing the performance of the pump

    Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications

    Get PDF
    Micro Electromechanical Systems (MEMS) based microfluidic devices have gained popularity in biomedicine field over the last few years. In this paper, a comprehensive overview of microfluidic devices such as micropumps and microneedles has been presented for biomedical applications. The aim of this paper is to present the major features and issues related to micropumps and microneedles, e.g., working principles, actuation methods, fabrication techniques, construction, performance parameters, failure analysis, testing, safety issues, applications, commercialization issues and future prospects. Based on the actuation mechanisms, the micropumps are classified into two main types, i.e., mechanical and non-mechanical micropumps. Microneedles can be categorized according to their structure, fabrication process, material, overall shape, tip shape, size, array density and application. The presented literature review on micropumps and microneedles will provide comprehensive information for researchers working on design and development of microfluidic devices for biomedical applications

    Electroosmosis modulated peristaltic biorheological flow through an asymmetric microchannel : mathematical model

    Get PDF
    A theoretical study is presented of peristaltic hydrodynamics of an aqueous electrolytic nonNewtonian Jeffrey bio-rheological fluid through an asymmetric microchannel under an applied axial electric field. An analytical approach is adopted to obtain the closed form solution for velocity, volumetric flow, pressure difference and stream function. The analysis is also restricted under the low Reynolds number assumption and lubrication theory approximations. Debye-HΓΌckel linearization (i.e. wall zeta potential ≀ 25mV) is also considered. Streamline plots are also presented for the different electro-osmotic parameter, varying magnitudes of the electric field (both aiding and opposing cases) and for different values of the ratio of relaxation to retardation time parameter. Comparisons are also included between the Newtonian and general non-Newtonian Jeffrey fluid cases. The results presented here may be of fundamental interest towards designing lab-on-a-chip devices for flow mixing, cell manipulation, micro-scale pumps etc. Trapping is shown to be more sensitive to an electric field (aiding, opposing and neutral) rather than the electro-osmotic parameter and viscoelastic relaxation to retardation ratio parameter. The results may also help towards the design of organ-on-a-chip like devices for better drug design

    Transverse magnetic field driven modification in unsteady peristaltic transport with electrical double layer effects

    Get PDF
    The influence of transverse magnetic field on time-dependent peristaltic transport of electrically-conducting fluids through a microchannel under an applied external electric field with induced electric field effect is considered, based on lubrication theory approximations. The electrohydrodynamic (EHD) problem is also simplified under the Debye linearization. Closed-form solutions for the linearized dimensionless boundary value problem are derived. With increasing Hartmann number, the formation of bolus in the regime (associated with trapping) is inhibited up to a critical value of magnetic field. Flow rate, axial velocity and local wall shear stress are strongly decreased with greater Hartmann number whereas pressure difference is enhanced with higher Hartmann number at low time values but reduced with greater elapse in time. With greater electro-osmotic parameter (i.e. smaller Debye length), maximum time-averaged flow rate is enhanced, whereas the axial velocity is reduced. An increase in electrical field parameter (i.e. maximum electro-osmotic velocity) causes an increase in maximum time-averaged flow rate. The simulations find applications in electromagnetic peristaltic micro-pumps in medical engineering and also β€œsmart” fluid pumping systems in nuclear and aerospace industries

    Experimental study of helical milling on CFRP (carbon fibre reinforced polymer) for the hole making process

    Get PDF
    Generate borehole by helical milling process may be used effectively since accurate location of the hole may be secured by means of the feed screw graduations. Fiber delamination which is the main defect occurred during hole making process on carbon fiber reinforced polymer (CFRP) were investigate throughout an experimental study. Effects of thrust force (Fz), delamination factor (Fd) and surface roughness are evaluated. Objective of the experiment are to find best cutting parameter and tool design suitable to performed helical milling operation on CFRP. Two types of end mill with 4 flutes were used and results are evaluated. It was found that tool design 2-1 has higher performance on CFRP
    • …
    corecore