1,057 research outputs found
A comprehensive survey of wireless body area networks on PHY, MAC, and network layers solutions
Recent advances in microelectronics and integrated circuits, system-on-chip design, wireless communication and intelligent low-power sensors have allowed the realization of a Wireless Body Area Network (WBAN). A WBAN is a collection of low-power, miniaturized, invasive/non-invasive lightweight wireless sensor nodes that monitor the human body functions and the surrounding environment. In addition, it supports a number of innovative and interesting applications such as ubiquitous healthcare, entertainment, interactive gaming, and military applications. In this paper, the fundamental mechanisms of WBAN including architecture and topology, wireless implant communication, low-power Medium Access Control (MAC) and routing protocols are reviewed. A comprehensive study of the proposed technologies for WBAN at Physical (PHY), MAC, and Network layers is presented and many useful solutions are discussed for each layer. Finally, numerous WBAN applications are highlighted
A Review of Wireless Body Area Networks for Medical Applications
Recent advances in Micro-Electro-Mechanical Systems (MEMS) technology,
integrated circuits, and wireless communication have allowed the realization of
Wireless Body Area Networks (WBANs). WBANs promise unobtrusive ambulatory
health monitoring for a long period of time and provide real-time updates of
the patient's status to the physician. They are widely used for ubiquitous
healthcare, entertainment, and military applications. This paper reviews the
key aspects of WBANs for numerous applications. We present a WBAN
infrastructure that provides solutions to on-demand, emergency, and normal
traffic. We further discuss in-body antenna design and low-power MAC protocol
for WBAN. In addition, we briefly outline some of the WBAN applications with
examples. Our discussion realizes a need for new power-efficient solutions
towards in-body and on-body sensor networks.Comment: 7 pages, 7 figures, and 3 tables. In V3, the manuscript is converted
to LaTe
THE-FAME: THreshold based Energy-efficient FAtigue MEasurment for Wireless Body Area Sensor Networks using Multiple Sinks
Wireless Body Area Sensor Network (WBASN) is a technology employed mainly for
patient health monitoring. New research is being done to take the technology to
the next level i.e. player's fatigue monitoring in sports. Muscle fatigue is
the main cause of player's performance degradation. This type of fatigue can be
measured by sensing the accumulation of lactic acid in muscles. Excess of
lactic acid makes muscles feel lethargic. Keeping this in mind we propose a
protocol \underline{TH}reshold based \underline{E}nergy-efficient
\underline{FA}tigue \underline{ME}asurement (THE-FAME) for soccer players using
WBASN. In THE-FAME protocol, a composite parameter has been used that consists
of a threshold parameter for lactic acid accumulation and a parameter for
measuring distance covered by a particular player. When any parameters's value
in this composite parameter shows an increase beyond threshold, the players is
declared to be in a fatigue state. The size of battery and sensor should be
very small for the sake of players' best performance. These sensor nodes,
implanted inside player's body, are made energy efficient by using multiple
sinks instead of a single sink. Matlab simulation results show the
effectiveness of THE-FAME.Comment: IEEE 8th International Conference on Broadband and Wireless
Computing, Communication and Applications (BWCCA'13), Compiegne, Franc
A Novel Framework for Software Defined Wireless Body Area Network
Software Defined Networking (SDN) has gained huge popularity in replacing
traditional network by offering flexible and dynamic network management. It has
drawn significant attention of the researchers from both academia and
industries. Particularly, incorporating SDN in Wireless Body Area Network
(WBAN) applications indicates promising benefits in terms of dealing with
challenges like traffic management, authentication, energy efficiency etc.
while enhancing administrative control. This paper presents a novel framework
for Software Defined WBAN (SDWBAN), which brings the concept of SDN technology
into WBAN applications. By decoupling the control plane from data plane and
having more programmatic control would assist to overcome the current lacking
and challenges of WBAN. Therefore, we provide a conceptual framework for SDWBAN
with packet flow model and a future direction of research pertaining to SDWBAN.Comment: Presented on 8th International Conference on Intelligent Systems,
Modelling and Simulatio
New intelligent network approach for monitoring physiological parameters : the case of Benin
Benin health system is facing many challenges as: (i) affordable high-quality health care to a growing population providing need, (ii) patients’ hospitalization time reduction, (iii) and presence time of the nursing staff optimization. Such challenges can be solved by remote monitoring of patients. To achieve this, five steps were followed. 1) Identification of the Wireless Body Area Network (WBAN) systems’ characteristics and the patient physiological parameters’ monitoring. 2) The national Integrated Patient Monitoring Network (RIMP) architecture modeling in a cloud of Technocenters. 3) Cross-analysis between the characteristics and the functional requirements identified. 4) Each Technocenter’s functionality simulation through: a) the design approach choice inspired by the life cycle of V systems; b) functional modeling through SysML Language; c) the communication technology and different architectures of sensor networks choice studying. 5) An estimate of the material resources of the national RIMP according to physiological parameters. A National Integrated Network for Patient Monitoring (RNIMP) remotely, ambulatory or not, was designed for Beninese health system. The implementation of the RNIMP will contribute to improve patients’ care in Benin. The proposed network is supported by a repository that can be used for its implementation, monitoring and evaluation. It is a table of 36 characteristic elements each of which must satisfy 5 requirements relating to: medical application, design factors, safety, performance indicators and materiovigilance
Characterization of the on-body path Loss at 2.45 GHz and energy efficient WBAN design for dairy cows
Wireless body area networks (WBANs) provide promising applications in the healthcare monitoring of dairy cows. The characterization of the path loss (PL) between on-body nodes constitutes an important step in the deployment of a WBAN. In this paper, the PL between nodes placed on the body of a dairy cow was determined at 2.45 GHz. Finite-difference time domain simulations with two half-wavelength dipoles placed 20 mm above a cow model were performed using a 3-D electromagnetic solver. Measurements were conducted on a live cow to validate the simulation results. Excellent agreement between measurements and simulations was achieved and the obtained PL values as a function of the transmitter-receiver separation were well fitted by a lognormal PL model with a PL exponent of 3.1 and a PL at reference distance ( 10 cm) of 44 dB. As an application, the packet error rate ( PER) and the energy efficiency of different WBAN topologies for dairy cows (i.e., single-hop, multihop, and cooperative networks) were investigated. The analysis results revealed that exploiting multihop and cooperative communication schemes decrease the PER and increase the optimal payload packet size. The analysis results revealed that exploiting multihop and cooperative communication schemes increase the optimal payload packet size and improve the energy efficiency by 30%
A Study of Medium Access Control Protocols for Wireless Body Area Networks
The seamless integration of low-power, miniaturised, invasive/non-invasive
lightweight sensor nodes have contributed to the development of a proactive and
unobtrusive Wireless Body Area Network (WBAN). A WBAN provides long-term health
monitoring of a patient without any constraint on his/her normal dailylife
activities. This monitoring requires low-power operation of
invasive/non-invasive sensor nodes. In other words, a power-efficient Medium
Access Control (MAC) protocol is required to satisfy the stringent WBAN
requirements including low-power consumption. In this paper, we first outline
the WBAN requirements that are important for the design of a low-power MAC
protocol. Then we study low-power MAC protocols proposed/investigated for WBAN
with emphasis on their strengths and weaknesses. We also review different
power-efficient mechanisms for WBAN. In addition, useful suggestions are given
to help the MAC designers to develop a low-power MAC protocol that will satisfy
the stringent WBAN requirements.Comment: 13 pages, 8 figures, 7 table
SIMPLE: Stable Increased-throughput Multi-hop Protocol for Link Efficiency in Wireless Body Area Networks
In this work, we propose a reliable, power efficient and high throughput
routing protocol for Wireless Body Area Networks (WBANs). We use multi-hop
topology to achieve minimum energy consumption and longer network lifetime. We
propose a cost function to select parent node or forwarder. Proposed cost
function selects a parent node which has high residual energy and minimum
distance to sink. Residual energy parameter balances the energy consumption
among the sensor nodes while distance parameter ensures successful packet
delivery to sink. Simulation results show that our proposed protocol maximize
the network stability period and nodes stay alive for longer period. Longer
stability period contributes high packet delivery to sink which is major
interest for continuous patient monitoring.Comment: IEEE 8th International Conference on Broadband and Wireless
Computing, Communication and Applications (BWCCA'13), Compiegne, Franc
Transmission Delay of Multi-hop Heterogeneous Networks for Medical Applications
Nowadays, with increase in ageing population, Health care market keeps
growing. There is a need for monitoring of Health issues. Body Area Network
consists of wireless sensors attached on or inside human body for monitoring
vital Health related problems e.g, Electro Cardiogram (ECG),
ElectroEncephalogram (EEG), ElectronyStagmography(ENG) etc. Data is recorded by
sensors and is sent towards Health care center. Due to life threatening
situations, timely sending of data is essential. For data to reach Health care
center, there must be a proper way of sending data through reliable connection
and with minimum delay. In this paper transmission delay of different paths,
through which data is sent from sensor to Health care center over heterogeneous
multi-hop wireless channel is analyzed. Data of medical related diseases is
sent through three different paths. In all three paths, data from sensors first
reaches ZigBee, which is the common link in all three paths. After ZigBee there
are three available networks, through which data is sent. Wireless Local Area
Network (WLAN), Worldwide Interoperability for Microwave Access (WiMAX),
Universal Mobile Telecommunication System (UMTS) are connected with ZigBee.
Each network (WLAN, WiMAX, UMTS) is setup according to environmental
conditions, suitability of device and availability of structure for that
device. Data from these networks is sent to IP-Cloud, which is further
connected to Health care center. Main aim of this paper is to calculate delay
of each link in each path over multihop wireless channel.Comment: BioSPAN with 7th IEEE International Conference on Broadband and
Wireless Computing, Communication and Applications (BWCCA 2012), Victoria,
Canada, 201
- …