860 research outputs found

    Accelerated Cardiac Diffusion Tensor Imaging Using Joint Low-Rank and Sparsity Constraints

    Full text link
    Objective: The purpose of this manuscript is to accelerate cardiac diffusion tensor imaging (CDTI) by integrating low-rankness and compressed sensing. Methods: Diffusion-weighted images exhibit both transform sparsity and low-rankness. These properties can jointly be exploited to accelerate CDTI, especially when a phase map is applied to correct for the phase inconsistency across diffusion directions, thereby enhancing low-rankness. The proposed method is evaluated both ex vivo and in vivo, and is compared to methods using either a low-rank or sparsity constraint alone. Results: Compared to using a low-rank or sparsity constraint alone, the proposed method preserves more accurate helix angle features, the transmural continuum across the myocardium wall, and mean diffusivity at higher acceleration, while yielding significantly lower bias and higher intraclass correlation coefficient. Conclusion: Low-rankness and compressed sensing together facilitate acceleration for both ex vivo and in vivo CDTI, improving reconstruction accuracy compared to employing either constraint alone. Significance: Compared to previous methods for accelerating CDTI, the proposed method has the potential to reach higher acceleration while preserving myofiber architecture features which may allow more spatial coverage, higher spatial resolution and shorter temporal footprint in the future.Comment: 11 pages, 16 figures, published on IEEE Transactions on Biomedical Engineerin

    Superresolution imaging: A survey of current techniques

    Full text link
    Cristóbal, G., Gil, E., Šroubek, F., Flusser, J., Miravet, C., Rodríguez, F. B., “Superresolution imaging: A survey of current techniques”, Proceedings of SPIE - The International Society for Optical Engineering, 7074, 2008. Copyright 2008. Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.Imaging plays a key role in many diverse areas of application, such as astronomy, remote sensing, microscopy, and tomography. Owing to imperfections of measuring devices (e.g., optical degradations, limited size of sensors) and instability of the observed scene (e.g., object motion, media turbulence), acquired images can be indistinct, noisy, and may exhibit insufficient spatial and temporal resolution. In particular, several external effects blur images. Techniques for recovering the original image include blind deconvolution (to remove blur) and superresolution (SR). The stability of these methods depends on having more than one image of the same frame. Differences between images are necessary to provide new information, but they can be almost unperceivable. State-of-the-art SR techniques achieve remarkable results in resolution enhancement by estimating the subpixel shifts between images, but they lack any apparatus for calculating the blurs. In this paper, after introducing a review of current SR techniques we describe two recently developed SR methods by the authors. First, we introduce a variational method that minimizes a regularized energy function with respect to the high resolution image and blurs. In this way we establish a unifying way to simultaneously estimate the blurs and the high resolution image. By estimating blurs we automatically estimate shifts with subpixel accuracy, which is inherent for good SR performance. Second, an innovative learning-based algorithm using a neural architecture for SR is described. Comparative experiments on real data illustrate the robustness and utilization of both methods.This research has been partially supported by the following grants: TEC2007-67025/TCM, TEC2006-28009-E, BFI-2003-07276, TIN-2004-04363-C03-03 by the Spanish Ministry of Science and Innovation, and by PROFIT projects FIT-070000-2003-475 and FIT-330100-2004-91. Also, this work has been partially supported by the Czech Ministry of Education under the project No. 1M0572 (Research Center DAR) and by the Czech Science Foundation under the project No. GACR 102/08/1593 and the CSIC-CAS bilateral project 2006CZ002

    Simultaneous estimation of super-resolved scene and depth map from low resolution defocused observations

    Get PDF
    This paper presents a novel technique to simultaneously estimate the depth map and the focused image of a scene, both at a super-resolution, from its defocused observations. Super-resolution refers to the generation of high spatial resolution images from a sequence of low resolution images. Hitherto, the super-resolution technique has been restricted mostly to the intensity domain. In this paper, we extend the scope of super-resolution imaging to acquire depth estimates at high spatial resolution simultaneously. Given a sequence of low resolution, blurred, and noisy observations of a static scene, the problem is to generate a dense depth map at a resolution higher than one that can be generated from the observations as well as to estimate the true high resolution focused image. Both the depth and the image are modeled as separate Markov random fields (MRF) and a maximum a posteriori estimation method is used to recover the high resolution fields. Since there is no relative motion between the scene and the camera, as is the case with most of the super-resolution and structure recovery techniques, we do away with the correspondence problem
    corecore