8,227 research outputs found

    Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    Get PDF
    The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping

    A statistical shape model for deformable surface

    Get PDF
    This short paper presents a deformable surface registration scheme which is based on the statistical shape modelling technique. The method consists of two major processing stages, model building and model fitting. A statistical shape model is first built using a set of training data. Then the model is deformed and matched to the new data by a modified iterative closest point (ICP) registration process. The proposed method is tested on real 3-D facial data from BU-3DFE database. It is shown that proposed method can achieve a reasonable result on surface registration, and can be used for patient position monitoring in radiation therapy and potentially can be used for monitoring of the radiation therapy progress for head and neck patients by analysis of facial articulation

    Towards 3D printed multifunctional immobilization for proton therapy: initial materials characterization

    Get PDF
    Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-speci c structure. In this rst step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes. Methods: Using four di erent 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominal dimension of 20×20×80 mm3 were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young’s modulus. To investigate the e ect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρe, the e ective atomic number Ze , and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coe cients, while proton irradiations were performed to measure the proton range shift of the samples. The direc- tional dependence of these properties was investigated by performing the irradiations for di erent orientations of the samples. Results: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young’s moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT-based characterization yielded Ze ranging from 5.91 to 10.43. The SPR and ρe both ranged from 0.6 to 1.22. The measured photon attenuation coe cients at clinical energies scaled linearly with ρe. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Ze . As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials. Conclusions: In this study, the rst step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical work ow for the rst time: from the material printing to DECT characterization with a veri cation through beam measurements. Besides a proof of concept for beam modi cation, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in-house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy

    On voxel-by-voxel accumulated dose for prostate radiation therapy using deformable image registration.

    Get PDF
    Since delivered dose is rarely the same with planned, we calculated the delivered total dose to ten prostate radiotherapy patients treated with rectal balloons using deformable dose accumulation (DDA) and compared it with the planned dose. The patients were treated with TomoTherapy using two rectal balloon designs: five patients had the Radiadyne balloon (balloon A), and five patients had the EZ-EM balloon (balloon B). Prostate and rectal wall contours were outlined on each pre-treatment MVCT for all patients. Delivered fractional doses were calculated using the MVCT taken immediately prior to delivery. Dose grids were accumulated to the last MVCT using DDA tools in Pinnacle3 TM (v9.100, Philips Radiation Oncology Systems, Fitchburg, USA). Delivered total doses were compared with planned doses using prostate and rectal wall DVHs. The rectal NTCP was calculated based on total delivered and planned doses for all patients using the Lyman model. For 8/10 patients, the rectal wall NTCP calculated using the delivered total dose was less than planned, with seven patients showing a decrease of more than 5% in NTCP. For 2/10 patients studied, the rectal wall NTCP calculated using total delivered dose was 2% higher than planned. This study indicates that for patients receiving hypofractionated radiotherapy for prostate cancer with a rectal balloon, total delivered doses to prostate is similar with planned while delivered dose to rectal walls may be significantly different from planned doses. 8/10 patients show significant correlation between rectal balloon anterior-posterior positions and some VD values

    Optimization of Decision Making in Personalized Radiation Therapy using Deformable Image Registration

    Get PDF
    Cancer has become one of the dominant diseases worldwide, especially in western countries, and radiation therapy is one of the primary treatment options for 50% of all patients diagnosed. Radiation therapy involves the radiation delivery and planning based on radiobiological models derived primarily from clinical trials. Since 2015 improvements in information technologies and data storage allowed new models to be created using the large volumes of treatment data already available and correlate the actually delivered treatment with outcomes. The goals of this thesis are to 1) construct models of patient outcomes after receiving radiation therapy using available treatment and patient parameters and 2) provide a method to determine real accumulated radiation dose including the impact of registration uncertainties. In Chapter 2, a model was developed predicting overall survival for patients with hepatocellular carcinoma or liver metastasis receiving radiation therapy. These models show which patients benefit from curative radiation therapy based on liver function, and the survival benefit of increased radiation dose on survival. In Chapter 3, a method was developed to routinely evaluate deformable image registration (DIR) with computer-generated landmark pairs using the scale-invariant feature transform. The method presented in this chapter created landmark sets for comparing lung 4DCT images and provided the same evaluation of DIR as manual landmark sets. In Chapter 4, an investigation was performed on the impact of DIR error on dose accumulation using landmarked 4DCT images as the ground truth. The study demonstrated the relationship between dose gradient, DIR error and dose accumulation error, and presented a method to determine error bars on the dose accumulation process. In Chapter 5, a method was presented to determine quantitatively when to update a treatment plan during the course of a multi-fraction radiation treatment of head and neck cancer. This method investigated the ability to use only the planned dose with deformable image registration to predict dose changes caused by anatomical deformations. This thesis presents the fundamental elements of a decision support system including patient pre-treatment parameters and the actual delivered dose using DIR while considering registration uncertainties

    A review of segmentation and deformable registration methods applied to adaptive cervical cancer radiation therapy treatment planning

    Get PDF
    Objective: Manual contouring and registration for radiotherapy treatment planning and online adaptation for cervical cancer radiation therapy in computed tomography (CT) and magnetic resonance images (MRI) are often necessary. However manual intervention is time consuming and may suffer from inter or intra-rater variability. In recent years a number of computer-guided automatic or semi-automatic segmentation and registration methods have been proposed. Segmentation and registration in CT and MRI for this purpose is a challenging task due to soft tissue deformation, inter-patient shape and appearance variation and anatomical changes over the course of treatment. The objective of this work is to provide a state-of-the-art review of computer-aided methods developed for adaptive treatment planning and radiation therapy planning for cervical cancer radiation therapy. Methods: Segmentation and registration methods published with the goal of cervical cancer treatment planning and adaptation have been identified from the literature (PubMed and Google Scholar). A comprehensive description of each method is provided. Similarities and differences of these methods are highlighted and the strengths and weaknesses of these methods are discussed. A discussion about choice of an appropriate method for a given modality is provided. Results: In the reviewed papers a Dice similarity coefficient of around 0.85 along with mean absolute surface distance of 2-4. mm for the clinically treated volume were reported for transfer of contours from planning day to the treatment day. Conclusions: Most segmentation and non-rigid registration methods have been primarily designed for adaptive re-planning for the transfer of contours from planning day to the treatment day. The use of shape priors significantly improved segmentation and registration accuracy compared to other models
    • 

    corecore