6 research outputs found

    Intra-Patient Supine-Prone Colon Registration in CT Colonography Using Shape Spectrum

    Full text link

    External Clinical Validation of Prone and Supine CT Colonography Registration

    Get PDF
    This paper provides an external validation of a prone-supine registration algorithm for CT colonography (CTC). A validation sample of 49 patient cases with 66 polyps (6 to 30 mm) was selected from a publicly available, anonymized CTC archive. To enhance generalizability, no case was excluded due to poor preparation or inadequate distension. Corresponding prone and supine polyp coordinates were recorded and the endoluminal surfaces registered: a Markov Random Field technique was used to find feature matches between prone/supine acquisitions and following mapping of the endoluminal surface to a cylinder, dense surface correspondence was achieved via cylindrical non-rigid registration. The polyp registration error was determined and a subjective assessment of registration made for 2D slice-based and 3D endoluminal data display using a pre-specified scoring system. Results were compared to using “normalized distance along the colon centerline” (NDACC) which approximates to the method currently employed to match colonic positions using proprietary CT colonography interpretation software. Registration was possible in all 49 cases. Overall mean 3D polyp registration error was significantly smaller with 19.9 mm in comparison to 27.7 mm using NDACC (p=0.001). 82.7% of polyp matches were defined as “successful” in comparison to 37.1% using NDACC according to the pre-specified criteria. Similarly, using 2D visualization, 62.1% registrations were “successful” and only 22.7% using NDACC. Full surface-based prone-to-supine registration can successfully map the location of a polyp identified on one acquisition to the corresponding endoluminal surface in the opposing acquisition, greatly facilitating polyp matching and aiding interpretation. Our method compares favorably to using NDACC

    Feature extraction to aid disease detection and assessment of disease progression in CT and MR colonography

    Get PDF
    Computed tomographic colonography (CTC) is a technique employed to examine the whole colon for cancers and premalignant adenomas (polyps). Oral preparation is taken to fully cleanse the colon, and gas insufflation maximises the attenuation contrast between the enoluminal colon surface and the lumen. The procedure is performed routinely with the patient both prone and supine to redistribute gas and residue. This helps to differentiate fixed colonic pathology from mobile faecal residue and also helps discover pathology occluded by retained fluid or luminal collapse. Matching corresponding endoluminal surface locations with the patient in the prone and supine positions is therefore an essential aspect of interpretation by radiologists; however, interpretation can be difficult and time consuming due to the considerable colonic deformations that occur during repositioning. Hence, a method for automated registration has the potential to improve efficiency and diagnostic accuracy. I propose a novel method to establish correspondence between prone and supine CT colonography acquisitions automatically. The problem is first simplified by detecting haustral folds which are elongated ridgelike endoluminal structures and can be identified by curvature based measurements. These are subsequently matched using appearance based features, and their relative geometric relationships. It is shown that these matches can be used to find correspondence along the full length of the colon, but may also be used in conjunction with other registration methods to achieve a more robust and accurate result, explicitly addressing the problem of colonic collapse. The potential clinical value of this method has been assessed in an external clinical validation, and the application to follow-up CTC surveillance has been investigated. MRI has recently been applied as a tool to quantitatively evaluate the therapeutic response to therapy in patients with Crohn's disease, and is the preferred choice for repeated imaging. A primary biomarker for this evaluation is the measurement of variations of bowel wall thickness on changing from the active phase of the disease to remission; however, a poor level of interobserver agreement of measured thickness is reported and therefore a system for accurate, robust and reproducible measurements is desirable. I propose a novel method which will automatically track sections of colon, by estimating the positions of elliptical cross sections. Subsequently, estimation of the positions of the inner and outer bowel walls are made based on image gradient information and therefore a thickness measurement value can be extracted

    Enhanced computer assisted detection of polyps in CT colonography

    Get PDF
    This thesis presents a novel technique for automatically detecting colorectal polyps in computed tomography colonography (CTC). The objective of the documented computer assisted diagnosis (CAD) technique is to deal with the issue of false positive detections without adversely affecting polyp detection sensitivity. The thesis begins with an overview of CTC and a review of the associated research areas, with particular attention given to CAD-CTC. This review identifies excessive false positive detections as a common problem associated with current CAD-CTC techniques. Addressing this problem constitutes the major contribution of this thesis. The documented CAD-CTC technique is trained with, and evaluated using, a series of clinical CTC data sets These data sets contain polyps with a range of different sizes and morphologies. The results presented m this thesis indicate the validity of the developed CAD-CTC technique and demonstrate its effectiveness m accurately detecting colorectal polyps while significantly reducing the number of false positive detections

    Facilitating Colorectal Cancer Diagnosis with Computed Tomographic Colonography

    Get PDF
    Computed tomographic colonography (CTC) is a diagnostic technique involving helical volume acquisition of the cleansed, distended colorectum to detect colorectal cancer or potentially premalignant polyps. This Thesis summarises the evidence base, identifies areas in need of further research, quantifies sources of bias and presents novel techniques to facilitate colorectal cancer diagnosis using CTC. CTC literature is reviewed to justify the rationale for current implementation and to identify fruitful areas for research. This confirms excellent diagnostic performance can be attained providing CTC is interpreted by trained, experienced observers employing state-of-the-art implementation. The technique is superior to barium enema and consequently, it has been embraced by radiologists, clinicians and health policy-makers. Factors influencing generalisability of CTC research are investigated, firstly with a survey of European educational workshop participants which revealed limited CTC experience and training, followed by a systematic review exploring bias in research studies of diagnostic test accuracy which established that studies focussing on these aspects were lacking. Experiments to address these sources of bias are presented, using novel methodology: Conjoint analysis is used to ascertain patients‘ and clinicians’ attitudes to false-positive screening diagnoses, showing that both groups overwhelmingly value sensitivity over specificity. The results inform a weighted statistical analysis for CAD which is applied to the results of two previous studies showing the incremental benefit is significantly higher for novices than experienced readers. We have employed eye-tracking technology to establish the visual search patterns of observers reading CTC, demonstrated feasibility and developed metrics for analysis. We also describe development and validation of computer software to register prone and supine endoluminal surface locations demonstrating accurate matching of corresponding points when applied to a phantom and a generalisable, publically available, CTC database. Finally, areas in need of future development are suggested
    corecore