Image-guided Simulation of Heterogeneous Tissue Deformation For Augmented Reality during Hepatic Surgery
International audienceThis paper presents a method for real-time augmentation of vas- cular network and tumors during minimally invasive liver surgery. Internal structures computed from pre-operative CT scans can be overlaid onto the laparoscopic view for surgery guidance. Com- pared to state-of-the-art methods, our method uses a real-time biomechanical model to compute a volumetric displacement field from partial three-dimensional liver surface motion. This permits to properly handle the motion of internal structures even in the case of anisotropic or heterogeneous tissues, as it is the case for the liver and many anatomical structures. Real-time augmentation results are presented on in vivo and ex vivo data and illustrate the benefits of such an approach for minimally invasive surgery
Impact of Soft Tissue Heterogeneity on Augmented Reality for Liver Surgery
International audienceThis paper presents a method for real-time augmented reality of internal liver structures during minimally invasive hepatic surgery. Vessels and tumors computed from pre-operative CT scans can be overlaid onto the laparoscopic view for surgery guidance. Compared to current methods, our method is able to locate the in-depth positions of the tumors based on partial three-dimensional liver tissue motion using a real-time biomechanical model. This model permits to properly handle the motion of internal structures even in the case of anisotropic or heterogeneous tissues, as it is the case for the liver and many anatomical structures. Experimentations conducted on phantom liver permits to measure the accuracy of the augmentation while real-time augmentation on in vivo human liver during real surgery shows the benefits of such an approach for minimally invasive surgery
Image-guided Simulation of Heterogeneous Tissue Deformation For Augmented Reality during Hepatic Surgery
International audienceThis paper presents a method for real-time augmentation of vas- cular network and tumors during minimally invasive liver surgery. Internal structures computed from pre-operative CT scans can be overlaid onto the laparoscopic view for surgery guidance. Com- pared to state-of-the-art methods, our method uses a real-time biomechanical model to compute a volumetric displacement field from partial three-dimensional liver surface motion. This permits to properly handle the motion of internal structures even in the case of anisotropic or heterogeneous tissues, as it is the case for the liver and many anatomical structures. Real-time augmentation results are presented on in vivo and ex vivo data and illustrate the benefits of such an approach for minimally invasive surgery
Iterative PnP and its application in 3D-2D vascular image registration for robot navigation
This paper reports on a new real-time robot-centered 3D-2D vascular image
alignment algorithm, which is robust to outliers and can align nonrigid shapes.
Few works have managed to achieve both real-time and accurate performance for
vascular intervention robots. This work bridges high-accuracy 3D-2D
registration techniques and computational efficiency requirements in
intervention robot applications. We categorize centerline-based vascular 3D-2D
image registration problems as an iterative Perspective-n-Point (PnP) problem
and propose to use the Levenberg-Marquardt solver on the Lie manifold. Then,
the recently developed Reproducing Kernel Hilbert Space (RKHS) algorithm is
introduced to overcome the ``big-to-small'' problem in typical robotic
scenarios. Finally, an iterative reweighted least squares is applied to solve
RKHS-based formulation efficiently. Experiments indicate that the proposed
algorithm processes registration over 50 Hz (rigid) and 20 Hz (nonrigid) and
obtains competing registration accuracy similar to other works. Results
indicate that our Iterative PnP is suitable for future vascular intervention
robot applications.Comment: Submitted to ICRA 202
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Locally rigid, vessel-based registration for laparoscopic liver surgery
Purpose: Laparoscopic liver resection has significant advantages over open surgery due to less patient trauma and faster recovery times, yet is difficult for most lesions due to the restricted field of view and lack of haptic feedback. Image guidance provides a potential solution but is challenging in a soft deforming organ such as the liver. In this paper, we therefore propose a laparoscopic ultrasound (LUS) image guidance system and study the feasibility of a locally rigid registration for laparoscopic liver surgery.
Methods: We developed a real-time segmentation method to extract vessel centre points from calibrated, freehand, electromagnetically tracked, 2D LUS images. Using landmark-based initial registration and an optional iterative closest point (ICP) point-to-line registration, a vessel centre-line model extracted from preoperative computed tomography (CT) is registered to the ultrasound data during surgery.
Results: Using the locally rigid ICP method, the RMS residual error when registering to a phantom was 0.7 mm, and the mean target registration error (TRE) for two in vivo porcine studies was 3.58 and 2.99 mm, respectively. Using the locally rigid landmark-based registration method gave a mean TRE of 4.23 mm using vessel centre lines derived from CT scans taken with pneumoperitoneum and 6.57 mm without pneumoperitoneum.
Conclusion: In this paper we propose a practical image-guided surgery system based on locally rigid registration of a CT-derived model to vascular structures located with LUS. In a physical phantom and during porcine laparoscopic liver resection, we demonstrate accuracy of target location commensurate with surgical requirements. We conclude that locally rigid registration could be sufficient for practically useful image guidance in the near future
Analytic description of the image to patient torso registration problem in image guided interventions
Objective: The accurate registration of virtual pre-operative information of the human body anatomy, obtained as images
with imaging devices, with real intra-operative information is one of the key aspects on which effective Image Guided
Surgery (IGS) is based. The registration of pre-operative images on the real patient, during abdominal and thoracic
interventions, is influenced by many parameters, which in many cases are influenced each other, thus making it often
difficult to define the problem and consequently to solve it for each specific kind of intervention. The objective of this
paper is to obtain an analytic description of the 3D image to patient registration problem, which can be more intuitive than
the traditional textual descriptions.
Methods: The problem is formalized and various parameters affecting the registration are macro-classified in function of
their nature.
Results: The problem is analytically described discussing for each macro-category of parameters potential solutions to
avoid or to reduce their contribution to the registration error.
Conclusions: The availability of an analytic description of the image to patient torso registration problem can be
beneficial for teaching IGS, to describe existing registration strategies, and to search new ones for each kind of surgery
using a systematic approach
Registration of ultrasound and computed tomography for guidance of laparoscopic liver surgery
Laparoscopic Ultrasound (LUS) imaging is a standard tool used for image-guidance during laparoscopic liver resection, as it provides real-time information on the internal structure of the liver. However, LUS probes are di cult to handle and their resulting images hard to interpret. Additionally, some anatomical targets such as tumours are not always visible, making the LUS guidance less e ective. To solve this problem, registration between the LUS images and a pre-operative Computed Tomography (CT) scan using information from blood vessels has been previously proposed. By merging these two modalities, the relative position between the LUS images and the anatomy of CT is obtained and both can be used to guide the surgeon. The problem of LUS to CT registration is specially challenging, as besides being a multi-modal registration, the eld of view of LUS is signi cantly smaller than that of CT. Therefore, this problem becomes poorly constrained and typically an accurate initialisation is needed. Also, the liver is highly deformed during laparoscopy, complicating the problem further. So far, the methods presented in the literature are not clinically feasible as they depend on manually set correspondences between both images. In this thesis, a solution for this registration problem that may be more transferable to the clinic is proposed. Firstly, traditional registration approaches comprised of manual initialisation and optimisation of a cost function are studied. Secondly, it is demonstrated that a globally optimal registration without a manual initialisation is possible. Finally, a new globally optimal solution that does not require commonly used tracking technologies is proposed and validated. The resulting approach provides clinical value as it does not require manual interaction in the operating room or tracking devices. Furthermore, the proposed method could potentially be applied to other image-guidance problems that require registration between ultrasound and a pre-operative scan
Development of an Atlas-Based Segmentation of Cranial Nerves Using Shape-Aware Discrete Deformable Models for Neurosurgical Planning and Simulation
Twelve pairs of cranial nerves arise from the brain or brainstem and control our sensory functions such as vision, hearing, smell and taste as well as several motor functions to the head and neck including facial expressions and eye movement. Often, these cranial nerves are difficult to detect in MRI data, and thus represent problems in neurosurgery planning and simulation, due to their thin anatomical structure, in the face of low imaging resolution as well as image artifacts. As a result, they may be at risk in neurosurgical procedures around the skull base, which might have dire consequences such as the loss of eyesight or hearing and facial paralysis. Consequently, it is of great importance to clearly delineate cranial nerves in medical images for avoidance in the planning of neurosurgical procedures and for targeting in the treatment of cranial nerve disorders. In this research, we propose to develop a digital atlas methodology that will be used to segment the cranial nerves from patient image data. The atlas will be created from high-resolution MRI data based on a discrete deformable contour model called 1-Simplex mesh. Each of the cranial nerves will be modeled using its centerline and radius information where the centerline is estimated in a semi-automatic approach by finding a shortest path between two user-defined end points. The cranial nerve atlas is then made more robust by integrating a Statistical Shape Model so that the atlas can identify and segment nerves from images characterized by artifacts or low resolution. To the best of our knowledge, no such digital atlas methodology exists for segmenting nerves cranial nerves from MRI data. Therefore, our proposed system has important benefits to the neurosurgical community
Coronary Artery Segmentation and Motion Modelling
Conventional coronary artery bypass surgery requires invasive sternotomy and the
use of a cardiopulmonary bypass, which leads to long recovery period and has high
infectious potential. Totally endoscopic coronary artery bypass (TECAB) surgery
based on image guided robotic surgical approaches have been developed to allow the
clinicians to conduct the bypass surgery off-pump with only three pin holes incisions
in the chest cavity, through which two robotic arms and one stereo endoscopic camera
are inserted. However, the restricted field of view of the stereo endoscopic images leads
to possible vessel misidentification and coronary artery mis-localization. This results
in 20-30% conversion rates from TECAB surgery to the conventional approach.
We have constructed patient-specific 3D + time coronary artery and left ventricle
motion models from preoperative 4D Computed Tomography Angiography (CTA)
scans. Through temporally and spatially aligning this model with the intraoperative
endoscopic views of the patient's beating heart, this work assists the surgeon to identify
and locate the correct coronaries during the TECAB precedures. Thus this work has
the prospect of reducing the conversion rate from TECAB to conventional coronary
bypass procedures.
This thesis mainly focus on designing segmentation and motion tracking methods
of the coronary arteries in order to build pre-operative patient-specific motion models.
Various vessel centreline extraction and lumen segmentation algorithms are presented,
including intensity based approaches, geometric model matching method and
morphology-based method. A probabilistic atlas of the coronary arteries is formed
from a group of subjects to facilitate the vascular segmentation and registration procedures.
Non-rigid registration framework based on a free-form deformation model
and multi-level multi-channel large deformation diffeomorphic metric mapping are
proposed to track the coronary motion. The methods are applied to 4D CTA images
acquired from various groups of patients and quantitatively evaluated
- …