109 research outputs found

    Mathematical Modeling and Empirical Validation of a Conceptual Exoskeleton for Astronaut Glove Augmentation

    Get PDF
    Space presents numerous difficulties for astronauts conducting their work, not the least of which is the spacesuit that is worn to protect them from space. It has long been known that a spacesuit is difficult to work in, especially the rigid and pressurized gloves that put strain on the astronaut\u27s hands, frequently leading to injuries. Astronaut gloves inhibit more than 50% of their strength in some cases [1]. NASA and other space agencies have been working to alleviate these problems by attempting to mechanically augment the gloves to reduce the exertions of the astronaut. To date, no augmentation systems have been implemented into spacesuits and prototypes are actively undergoing design and development [2] [3]. Currently existing prototypes are impractical, unconformable, or not effectively augmenting the astronaut as evidenced by the non-implementation of such systems to date. This work presents a novel conceptual exoskeleton design for astronaut glove augmentation and a mathematical model that is used to predict its performance. In addition, experiments were conducted to validate the math model. The conceptual exoskeleton is designed to overcome the shortcomings of previous attempts to augment astronaut gloves by using rigid linkages actuated by a single tendon routed through them. This system operates exclusively on the dorsal surface of the hand, limiting the restrictions to the palmar surface of the hand. The mathematical model presents a method to equate the tendon tension to the contact force between the linkages and the object that is being grasped. Two representative models of the conceptual exoskeleton were built and tested. The experimental fixture, custom designed and fabricated, used a Pliance Pressure Pad to measure the total forces produced by the system. The measured force values were then compared to predictions made by the system to assess the accuracy of the mathematical model. The experimental configurations of the systems were measured using a machine vision system. The mathematical model was shown to accurately predict the contact forces produced by the representative test rigs. Relationships between the contact forces developed in a grasp and the readings from a Jamar Grip Dynamometer were then used to estimate the magnitude of grip strength that the full exoskeleton could develop [4]. These estimations indicate that the conceptual system would be able to recover up to 124% of the strength that astronauts lose to their gloves

    Design and development of robust hands for humanoid robots

    Get PDF
    Design and development of robust hands for humanoid robot

    ReHand - a portable assistive rehabilitation hand exoskeleton

    Get PDF
    This dissertation presents a synthesis of a novel underactuated exoskeleton (namely ReHand2) thought and designed for a task-oriented rehabilitation and/or for empower the human hand. The first part of this dissertation shows the current context about the robotic rehabilitation with a focus on hand pathologies, which influence the hand capability. The chapter is concluded with the presentation of ReHand2. The second chapter describes the human hand biomechanics. Starting from the definition of human hand anatomy, passing through anthropometric data, to taxonomy on hand grasps and finger constraints, both from static and dynamic point of view. In addition, some information about the hand capability are given. The third chapter analyze the current state of the art in hand exoskeleton for rehabilitation and empower tasks. In particular, the chapter presents exoskeleton technologies, from mechanisms to sensors, passing though transmission and actuators. Finally, the current state of the art in terms of prototype and commercial products is presented. The fourth chapter introduces the concepts of underactuation with the basic explanation and the classical notation used typically in the prosthetic field. In addition, the chapter describe also the most used differential elements in the prosthetic, follow by a statical analysis. Moreover typical transmission tree at inter-finger level as well as the intra- finger underactuation are explained . The fifth chapter presents the prototype called ReHand summarizing the device description and explanation of the working principle. It describes also the kinetostatic analysis for both, inter- and the intra-finger modules. in the last section preliminary results obtained with the exoskeleton are shown and discussed, attention is pointed out on prototype’s problems that have carry out at the second version of the device. The sixth chapter describes the evolution of ReHand, describing the kinematics and dynamics behaviors. In particular, for the mathematical description is introduced the notation used in order to analyze and optimize the geometry of the entire device. The introduced model is also implemented in Matlab Simulink environment. Finally, the chapter presents the new features. The seventh chapter describes the test bench and the methodologies used to evaluate the device statical, and dynamical performances. The chapter presents and discuss the experimental results and compare them with simulated one. Finally in the last chapter the conclusion about the ReHand project are proposed as well as the future development. In particular, the idea to test de device in relevant environments. In addition some preliminary considerations about the thumb and the wrist are introduced, exploiting the possibility to modify the entire layout of the device, for instance changing the actuator location

    Elastic Structure Preserving Impedance Control for Nonlinearly Coupled Tendon-Driven Systems

    Get PDF
    Traditionally, most of the nonlinear control techniques for elastic robotic systems focused on achieving a desired closed-loop behavior by modifying heavily the intrinsic properties of the plant. This is also the case of elastic tendon-driven systems, where the highly nonlinear couplings lead to several control challenges. Following the current philosophy of exploiting the mechanical compliance rather than fighting it, this letter proposes an Elastic Structure Preserving impedance (ESPi) control for systems with coupled elastic tendinous transmissions. Our strategy achieves a globally asymptotically stable closed-loop system that minimally shapes the intrinsic inertial and elastic structure. %to add desired stiffness and damping on the link side. It further allows to impose a desired link-side impedance behavior. Simulations performed on the tendon-driven index finger of the DLR robot David show satisfactory results of link-side interaction behavior and set-point regulation

    Design and implementation of robotic devices for physical therapy of distal upper extremity

    Get PDF
    According to statistics of World Health Organization, hand injuries count for 1/3 of all injuries with more than one million emergency cases annually. Physical rehabilitation accounts for most of the recovery experienced by patients suffering from hand injury. Robotic devices decrease the cost of therapy while providing repetitive exercises with quantitative measurements. In this study, we present the design and implementation of two robotic devices for hand therapy. After kinematic type selection ensuring safety, ergonomics and adjustability; both of the devices are optimally dimensioned to achieve best kinematic and dynamic performance. The primary use for the first device is to assist flexion/extension motions of a finger within its full range, in a natural and coordinated manner, while keeping the tendon tension within acceptable limits to avoid rupture of the suture. The second device is designed for forearm/wrist and grasp therapy of a neurologically injured human arm and hand. Emphasizing the importance of coordinated movements of the wrist and the hand while performing activities of daily living (ADL) tasks, the device possesses 3 degrees of freedom and is designed to assist abduction/adduction and palmar/dorsal flexion of the wrist or pronation/supination of the forearm, concurrently with the grasping and releasing movements of the hand. Thanks to its modular, interchangeable end effectors, the device supports ADL exercises. Both devices are built and experimentally characterized. Human subject experiments and usability tests have been conducted for the devices and the efficacy of devices to deliver desired wrist and hand therapies have been demonstrated

    Separable Tendon-Driven Robotic Manipulator with a Long, Flexible, Passive Proximal Section

    Full text link
    This work tackles practical issues which arise when using a tendon-driven robotic manipulator (TDRM) with a long, flexible, passive proximal section in medical applications. Tendon-driven devices are preferred in medicine for their improved outcomes via minimally invasive procedures, but TDRMs come with unique challenges such as sterilization and reuse, simultaneous control of tendons, hysteresis in the tendon-sheath mechanism, and unmodeled effects of the proximal section shape. A separable TDRM which overcomes difficulties in actuation and sterilization is introduced, in which the body containing the electronics is reusable and the remainder is disposable. An open-loop redundant controller which resolves the redundancy in the kinematics is developed. Simple linear hysteresis compensation and re-tension compensation based on the physical properties of the device are proposed. The controller and compensation methods are evaluated on a testbed for a straight proximal section, a curved proximal section at various static angles, and a proximal section which dynamically changes angles; and overall, distal tip error was reduced

    Kinematics and Robot Design IV, KaRD2021

    Get PDF
    This volume collects the papers published on the special issue “Kinematics and Robot Design IV, KaRD2021” (https://www.mdpi.com/journal/robotics/special_issues/KaRD2021), which is the forth edition of the KaRD special-issue series, hosted by the open-access journal “MDPI Robotics”. KaRD series is an open environment where researchers can present their works and discuss all the topics focused on the many aspects that involve kinematics in the design of robotic/automatic systems. Kinematics is so intimately related to the design of robotic/automatic systems that the admitted topics of the KaRD series practically cover all the subjects normally present in well-established international conferences on “mechanisms and robotics”. KaRD2021, after the peer-review process, accepted 12 papers. The accepted papers cover some theoretical and many design/applicative aspects

    Designing a robotic port system for laparo-endoscopic single-site surgery

    Get PDF
    Current research and development in the field of surgical interventions aim to reduce the invasiveness by using few incisions or natural orifices in the body to access the surgical site. Considering surgeries in the abdominal cavity, the Laparo-Endoscopic Single-site Surgery (LESS) can be performed through a single incision in the navel, reducing blood loss, post-operative trauma, and improving the cosmetic outcome. However, LESS results in less intuitive instrument control, impaired ergonomic, loss of depth and haptic perception, and restriction of instrument positioning by a single incision. Robot-assisted surgery addresses these shortcomings, by introducing highly articulated, flexible robotic instruments, ergonomic control consoles with 3D visualization, and intuitive instrument control algorithms. The flexible robotic instruments are usually introduced into the abdomen via a rigid straight port, such that the positioning of the tools and therefore the accessibility of anatomical structures is still constrained by the incision location. To address this limitation, articulated ports for LESS are proposed by recent research works. However, they focus on only a few aspects, which are relevant to the surgery, such that a design considering all requirements for LESS has not been proposed yet. This partially originates in the lack of anatomical data of specific applications. Further, no general design guidelines exist and only a few evaluation metrics are proposed. To target these challenges, this thesis focuses on the design of an articulated robotic port for LESS partial nephrectomy. A novel approach is introduced, acquiring the available abdominal workspace, integrated into the surgical workflow. Based on several generated patient datasets and developed metrics, design parameter optimization is conducted. Analyzing the surgical procedure, a comprehensive requirement list is established and applied to design a robotic system, proposing a tendon-driven continuum robot as the articulated port structure. Especially, the aspects of stiffening and sterile design are addressed. In various experimental evaluations, the reachability, the stiffness, and the overall design are evaluated. The findings identify layer jamming as the superior stiffening method. Further, the articulated port is proven to enhance the accessibility of anatomical structures and offer a patient and incision location independent design

    Development and Biomechanical Analysis toward a Mechanically Passive Wearable Shoulder Exoskeleton

    Get PDF
    Shoulder disability is a prevalent health issue associated with various orthopedic and neurological conditions, like rotator cuff tear and peripheral nerve injury. Many individuals with shoulder disability experience mild to moderate impairment and struggle with elevating the shoulder or holding the arm against gravity. To address this clinical need, I have focused my research on developing wearable passive exoskeletons that provide continuous at-home movement assistance. Through a combination of experiments and computational tools, I aim to optimize the design of these exoskeletons. In pursuit of this goal, I have designed, fabricated, and preliminarily evaluated a wearable, passive, cam-driven shoulder exoskeleton prototype. Notably, the exoskeleton features a modular spring-cam-wheel module, allowing customizable assistive force to compensate for different proportions of the shoulder elevation moment due to gravity. The results of my research demonstrated that this exoskeleton, providing modest one-fourth gravity moment compensation at the shoulder, can effectively reduce muscle activity, including deltoid and rotator cuff muscles. One crucial aspect of passive shoulder exoskeleton design is determining the optimal anti-gravity assistance level. I have addressed this challenge using computational tools and found that an assistance level within the range of 20-30% of the maximum gravity torque at the shoulder joint yields superior performance for specific shoulder functional tasks. When facing a new task dynamic, such as wearing a passive shoulder exoskeleton, the human neuro-musculoskeletal system adapts and modulates limb impedance at the end-limb (i.e., hand) to enhance task stability. I have presented development and validation of a realistic neuromusculoskeletal model of the upper limb that can predict stiffness modulation and motor adaptation in response to newly introduced environments and force fields. Future studies will explore the model\u27s applicability in predicting stiffness modulation for 3D movements in novel environments, such as passive assistive devices\u27 force fields
    • …
    corecore