138,227 research outputs found

    The green valley is a red herring : Galaxy Zoo reveals two evolutionary pathways towards quenching of star formation in early-and late-type galaxies

    Get PDF
    This is a pre-copyedited, author-produced PDF of an article accepted for publication in Monthly Notices of the Royal Astronomical Society following peer review. The version of record [Kevin Schawinski, et al, 'The green valley is a red herring: Galaxy Zoo reveals two evolutionary pathways towards quenching of star formation in early- and late-type galaxies' MNRAS, Vol. 440(1): 889-907, May 2014] is available online at: https://doi.org/10.1093/mnras/stu327.We use SDSS+GALEX+Galaxy Zoo data to study the quenching of star formation in lowredshift galaxies. We show that the green valley between the blue cloud of star-forming galaxies and the red sequence of quiescent galaxies in the colour-mass diagram is not a single transitional state through which most blue galaxies evolve into red galaxies. Rather, an analysis that takes morphology into account makes clear that only a small population of blue early-type galaxies move rapidly across the green valley after the morphologies are transformed from disc to spheroid and star formation is quenched rapidly. In contrast, the majority of blue star-forming galaxies have significant discs, and they retain their late-type morphologies as their star formation rates decline very slowly. We summarize a range of observations that lead to these conclusions, including UV-optical colours and halo masses, which both show a striking dependence on morphological type. We interpret these results in terms of the evolution of cosmic gas supply and gas reservoirs. We conclude that late-type galaxies are consistent with a scenario where the cosmic supply of gas is shut off, perhaps at a critical halo mass, followed by a slow exhaustion of the remaining gas over several Gyr, driven by secular and/or environmental processes. In contrast, early-type galaxies require a scenario where the gas supply and gas reservoir are destroyed virtually instantaneously, with rapid quenching accompanied by a morphological transformation from disc to spheroid. This gas reservoir destruction could be the consequence of a major merger, which in most cases transforms galaxies from disc to elliptical morphology, and mergers could play a role in inducing black hole accretion and possibly active galactic nuclei feedback.Peer reviewe

    2014 Bone and Muscle Risks Standing Review Panel

    Get PDF
    The 2014 Bone and Muscle Risks Standing Review Panel (from here on referred to as the SRP) met for a site visit in Houston, TX on December 17 - 18, 2014. The SRP reviewed the updated research plans for the Risk of Impaired Performance Due to Reduced Muscle Mass, Strength and Endurance (Muscle Risk) and the Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity (Aerobic Risk). The SRP also received a status update on the Risk of Bone Fracture (Bone Risk), the Risk of Early Onset Osteoporosis Due To Spaceflight (Osteo Risk), the Risk of Intervertebral Disc Damage (IVD Risk), and the Risk of Renal Stone Formation (Renal Risk)

    Discovery of a new Y dwarf: WISE J030449.03-270508.3

    Get PDF
    This is a pre-copyedited, author-produced PDF of an article accepted for publication in Monthly Notices of the Royal Astronomical Society following peer review. The version of record [D. J. Pinfield, et al, Discovery of a new Y dwarf: WISE J030449.03−270508.3, MNRAS, Vol. 444 (2): 1931-1939, September 2014] is available online at: https://doi.org/10.1093/mnras/stu1540.We present a new Y dwarf, WISE J030449.03−270508.3, confirmed from a candidate sample designed to pick out low-temperature objects from the Wide-field Infrared Survey Explorer (WISE) data base. The new object is typed Y0pec following a visual comparison with spectral standards, and lies at a likely distance of 10–17 pc. Its tangential velocity suggests thin disc membership, but it shows some spectral characteristics that suggest that it may be metal poor and/or older than previously identified Y0 dwarfs. Based on trends seen for warmer late-type T dwarfs, the Y-band flux peak morphology is indicative of sub-solar metallicity, and the enhanced red wing of the J-band flux peak offers evidence for high gravity and/or low metallicity (with associated model trends suggesting an age closer to ∼10 Gyr and mass in the range 0.02–0.03 Mȯ). This object may thus be extending the population parameter space of the known Y0 dwarfs.Peer reviewe

    Trends and Costs of External Electrical Bone Stimulators and Grafting Materials in Anterior Lumbar Interbody Fusion.

    Get PDF
    STUDY DESIGN: Retrospective review. PURPOSE: To identify the trends in stimulator use, pair those trends with various grafting materials, and determine the influence of stimulators on the risk of revision surgery. OVERVIEW OF LITERATURE: A large number of studies has reported beneficial effects of electromagnetic energy in healing long bone fractures. However, there are few clinical studies regarding the use of electrical stimulators in spinal fusion. METHODS: We used insurance billing codes to identify patients with lumbar disc degeneration who underwent anterior lumbar interbody fusion (ALIF). Comparisons between patients who did and did not receive electrical stimulators following surgery were performed using logistic regression analysis, chi-square test, and odds ratio (OR) analysis. RESULTS: Approximately 19% of the patients (495/2,613) received external stimulators following ALIF surgery. There was a slight increase in stimulator use from 2008 to 2014 (multi-level R2=0.08, single-level R2=0.05). Patients who underwent multi-level procedures were more likely to receive stimulators than patients who underwent single-level procedures (p0.05), except those in the multilevel ALIF+PLF cohort, wherein the patients who underwent stimulation had higher rates of revision surgery. CONCLUSIONS: Concurrent PLF or multi-level procedures increased patients\u27 likelihood of receiving stimulators, however, the presence of comorbidities did not. Patients who received BMA plus autograft or allograft were more likely to receive stimulation. Patients with and without bone stimulators had similar rates of revision surgery

    High-resolution magnetic resonance imaging and diffusion tensor imaging of the porcine temporomandibular joint disc

    Get PDF
    This is the published version. Copyright © 2014 The British Institute of RadiologyObjectives: Diffusion tensor imaging (DTI) is an MRI modality for characterizing the property, microstructural organization and function in tissues such as the brain and spinal cord. Prior to this investigation, DTI had not been adapted for studies of the temporomandibular joint (TMJ) disc. Objectives were to test the feasibility of DTI to evaluate the porcine TMJ disc and to use DTI to observe differences in magnitude of anisotropy of water diffusion between TMJ disc regions. Methods: Five adult pig TMJs were scanned on a 9.4 Tesla horizontal bore MRI scanner using an inductively coupled surface coil. High-resolution gradient-echo and diffusion-weighted spin-echo based images were obtained. The mean diffusivity and fractional anisotropy (FA) were computed in different regions of the disc. Two observers were calibrated to review the two-dimensional and three-dimensional images. Polarized light microscopy was used as the gold standard for collagen fibre orientation. Results: In the sagittal plane, the mean diffusivity was higher in the posterior (1.28±0.10×10−3 mm−2 s−1) and anterior (1.27±0.08×10−3 mm−2 s−1) bands compared with the intermediate zone (0.96±0.01×10−3 mm−2 s−1), and the FA index was also lowest in the intermediate zone. In the coronal plane, the mean diffusivity was higher in the medial (1.42±0.01×10−3 mm−2 s−1) and lateral (1.21±0.12×10−3 mm−2 s−1) aspects than in the centre (1.09±0.08×10−3 mm−2 s−1), and the FA index was also lowest in the centre. Conclusions: DTI is a useful method for non-invasively characterizing the structure/property relationships of the porcine TMJ disc

    Which Design and Biomaterial Factors Affect Clinical Wear Performance of Total Disc Replacements? A Systematic Review

    Get PDF
    Background Total disc replacement was clinically introduced to reduce pain and preserve segmental motion of the lumbar and cervical spine. Previous case studies have reported on the wear and adverse local tissue reactions around artificial prostheses, but it is unclear how design and biomaterials affect clinical outcomes. Questions/purposes Which design and material factors are associated with differences in clinical wear performance (implant wear and periprosthetic tissue response) of (1) lumbar and (2) cervical total disc replacements? Methods We performed a systematic review on the topics of implant wear and periprosthetic tissue response using an advanced search in MEDLINE and Scopus electronic databases. Of the 340 references identified, 33 were retrieved for full-text evaluation, from which 16 papers met the inclusion criteria (12 on lumbar disc replacement and five on cervical disc replacement; one of the included studies reported on both lumbar and cervical disc replacement), which involved semiquantitative analysis of wear and adverse local tissue reactions along with a description of the device used. An additional three papers were located by searching bibliographies of key articles. There were seven case reports, three case series, two case-control studies, and seven analytical studies. The Methodological Index for Non-randomized Studies (MINORS) Scale was used to score case series and case-control studies, which yielded mean scores of 10.3 of 16 and 17.5 of 24, respectively. In general, the case series (three) and case-control (two) studies were of good quality. Results In lumbar regions, metal-on-polymer devices with mobile-bearing designs consistently generated small and large polymeric wear debris, triggering periprosthetic tissue activation of macrophages and giant cells, respectively. In the cervical regions, metal-on-polymer devices with fixed-bearing designs had similar outcomes. All metal-on-metal constructs tended to generate small metallic wear debris, which typically triggered an adaptive immune response of predominantly activated lymphocytes. There were no retrieval studies on one-piece prostheses. Conclusions This review provides evidence that design and biomaterials affect the type of wear and inflammation. However, clinical study design, followup, and analytical techniques differ among investigations, preventing us from drawing firm conclusions about the relationship between implant design and wear performance for both cervical and lumbar total disc replacement

    Degeneration of the intervertebral disc with new approaches for treating low back pain.

    Get PDF
    This review paper discusses the process of disc degeneration and the current understanding of cellular degradation in patients who present with low back pain. The role of surgical treatment for low back pain is analysed with emphasis on the proven value of spinal fusion. The interesting and novel developments of stem cell research in the treatment of low back pain are presented with special emphasis on the importance of the cartilaginous end plate and the role of IL-1 in future treatment modalities
    • …
    corecore