Modified half-bridge modular multilevel converter for HVDC systems with DC fault ride-through capability
One of the main challenges of voltage source converter based HVDC systems is DC faults. In this paper, two different modified half-bridge modular multilevel converter topologies are proposed. The proposed converters offer a fault tolerant against the most severe pole-to-pole DC faults. The converter comprises three switches or two switches and 4 diodes in each cell, which can result in less cost and losses compared to the full-bridge modular multilevel converter. Converter structure and controls are presented including the converter modulation and capacitors balancing. MATLAB/SIMULINK simulations are carried out to verify converter operation in normal and faulty conditions
The Essential Role and the Continuous Evolution of Modulation Techniques for Voltage-Source Inverters in the Past, Present, and Future Power Electronics
The cost reduction of power-electronic devices, the increase in their reliability, efficiency, and power capability, and lower development times, together with more demanding application requirements, has driven the development of several new inverter topologies recently introduced in the industry, particularly medium-voltage converters. New more complex inverter topologies and new application fields come along with additional control challenges, such as voltage imbalances, power-quality issues, higher efficiency needs, and fault-tolerant operation, which necessarily requires the parallel development of modulation schemes. Therefore, recently, there have been significant advances in the field of modulation of dc/ac converters, which conceptually has been dominated during the last several decades almost exclusively by classic pulse-width modulation (PWM) methods. This paper aims to concentrate and discuss the latest developments on this exciting technology, to provide insight on where the state-of-the-art stands today, and analyze the trends and challenges driving its future
Comparison between flying capacitor and modular multilevel inverter
The paper describes the operational principle of flying capacitor and modular multilevel inverters. The detailed discussions of dc link capacitors voltage balancing methods for both inverters are given in order to enable fair comparison. The causes of dc link capacitors voltage imbalance in flying capacitor multilevel inverter with more than three levels are highlighted. Computer simulation is used to compare the performance of both inverters under several operating conditions
Developed cascaded multilevel inverter topology to minimise the number of circuit devices and voltage stresses of switches
In this study, a novel structure for cascade multilevel inverter is presented. The proposed inverter can generate all possible DC voltage levels with the value of positive and negative. The proposed structure results in reduction of switches number, relevant gate driver circuits and also the installation area and inverter cost. The suggested inverter can be used as symmetric and asymmetric structures. Comparing the peak inverse voltage and losses of the proposed inverter with conventional multilevel inverters show the superiority of the proposed converter. The operation and good performance of the proposed multilevel inverter have been verified by the simulation results of a single-phase nine-level symmetric and 17-level asymmetric multilevel inverter and experimental results of a nine-level and 17-level inverters. Simulation and experimental results confirmed the validity and effectiveness performance of the proposed inverter
A hybrid multilevel converter for medium and high voltage applications
This paper investigates the suitability of the hybrid multilevel converter for medium and high voltage application. The converter operation, modulation, and capacitor voltage balancing method are described in detail. The ability of the hybrid multilevel converter to operate with different modulation indices and load power factors is investigated. It has been established that the hybrid multilevel converter is capable of operating independent of load power factor. Operation with variable modulation index increases voltage stresses on the converter switches and does not alter the fundamental voltage magnitude as in all known voltage source converter topologies. The viability of the hybrid multilevel converter for medium and high voltage applications is confirmed by simulations
Full Bridge MMC Converter Optimal Design to HVDC Operational Requirements
This project is funded by RTE, Paris, FrancePeer reviewedPostprin
Hybrid and modular multilevel converter designs for isolated HVDC–DC converters
Efficient medium and high-voltage dc-dc conversion is critical for future dc grids. This paper proposes a hybrid multilevel dc-ac converter structure that is used as the kernel of dc-dc conversion systems. Operation of the proposed dc-ac converter is suited to trapezoidal ac-voltage waveforms. Quantitative and qualitative analyses show that said trapezoidal operation reduces converter footprint, active and passive components' size, and on-state losses relative to conventional modular multilevel converters. The proposed converter is scalable to high voltages with controllable ac-voltage slope; implying tolerable dv/dt stresses on the converter transformer. Structural variations of the proposed converter with enhanced modularity and improved efficiency will be presented and discussed with regards to application in front-to-front isolated dc-dc conversion stages, and in light of said trapezoidal operation. Numerical results provide deeper insight of the presented converter designs with emphasis on system design aspects. Results obtained from a proof-of-concept 1-kW experimental test rig confirm the validity of simulation results, theoretical analyses, and simplified design equations presented in this paper. - 2013 IEEE.Scopu
Multilevel Converters: An Enabling Technology for High-Power Applications
| Multilevel converters are considered today as the
state-of-the-art power-conversion systems for high-power and
power-quality demanding applications. This paper presents a
tutorial on this technology, covering the operating principle and
the different power circuit topologies, modulation methods,
technical issues and industry applications. Special attention is
given to established technology already found in industry with
more in-depth and self-contained information, while recent
advances and state-of-the-art contributions are addressed with
useful references. This paper serves as an introduction to the
subject for the not-familiarized reader, as well as an update or
reference for academics and practicing engineers working in
the field of industrial and power electronics.Ministerio de Ciencia y Tecnología DPI2001-3089Ministerio de Eduación y Ciencia d TEC2006-0386
Analysis of the power balance In the cells of a multilevel cascaded H-Bridge converter
Multilevel cascaded H-Bridge converters (CHB)
have been presented as a good solution for high power applications.
In this way, several control and modulation techniques
have been proposed for this power converter topology. In this
paper the steady state power balance in the cells of the single
phase two cell CHB is studied. The capability to be supplied with
active power from the grid or to deliver active power to the grid
in each cell is analyzed according to the dc-link voltages and
the desired ac output voltage value. Limits of the maximum and
minimum input active power for stable operation of the CHB are
addressed. Simulation results are shown to validate the presented
analysis
Variable-Angle Phase-Shifted PWM for Multilevel Three-Cell Cascaded H-bridge Converters
Multilevel cascaded H-bridge converters have become a mature technology for applications where high-power medium ac voltages are required. Normal operation of multilevel cascaded H-bridge converters assumes that all power cells have the same dc voltage, and each power cell generates the same voltage averaged over a sampling period using a conventional phase-shifted pulse width modulation (PWM) technique. However, this modulation method does not achieve good results under unbalanced operation per H-bridge in the power converter, which may happen in grid-connected applications such as photovoltaic or battery energy storage systems. In the paper, a simplified mathematical analysis of the phase-shifted PWM technique is presented. In addition, a modification of this conventional modulation method using variable shift angles between the power cells is introduced. This modification leads to the elimination of harmonic distortion of low-order harmonics due to the switching (triangular carrier frequency and its multiples) even under unbalanced operational conditions. The analysis is particularized for a three-cell cascaded H-bridge converter, and experimental results are presented to demonstrate the good performance of the proposed modulation method
- …