87 research outputs found

    Millimetre-wave radar development for high resolution detection

    Get PDF
    Automotive technology today is focusing on autonomous vehicle development. The sensors for these systems include radars due to their robustness against adverse weather conditions such as rain, fog, ash or snow. In this constant search for advancement, high resolution systems play a central role in target detection and avoidance. In this PhD project, these methods have been researched and engineered to leverage the best radar resolution for collision avoidance systems. The first part of this thesis will focus on the existing systems consisting of the state-of-the-art at the time of writing and explain what makes a high resolution radar and how it can cover the whole field of view. The second part will focus on how a non-uniform sparse radar system was simulated, developed and benchmarked for improved radar performance up to 40% better than conventional designs. The third part will focus on signal processing techniques and how these methods have achieved high resolution and detection: large virtual aperture array using Multiple Input Multiple Output (MIMO) systems, beampattern multiplication to improve side-lobe levels and compressive sensing. Also, the substrate-integrated waveguide (SIW) antennas which have been fabricated provide a bandwidth of 1.5GHz for the transmitter and 2GHz at the receiver. This has resulted in a range resolution of 10 cm. The four part of this thesis presents the measurements which have been carried out at the facilities within Heriot-Watt University and also at Netherlands Organisation for Applied Scientific Research (TNO). The results were better than expected since a two transmitter four receiver system was able to detect targets which have been separated at 2.2â—¦ in angle in the horizontal plane. Also, compressive sensing was used as a high resolution method for obtaining fine target detection and in combination with the multiplication method showed improved detection performance with a 20 dB side-lobe level suppression. The measurement results from the 6-months placements are presented and compared with the state-of the art, revealing that the developed radar is comparable in performance to high-grade automotive radars developed in the industry

    1-D broadside-radiating leaky-wave antenna based on a numerically synthesized impedance surface

    Get PDF
    A newly-developed deterministic numerical technique for the automated design of metasurface antennas is applied here for the first time to the design of a 1-D printed Leaky-Wave Antenna (LWA) for broadside radiation. The surface impedance synthesis process does not require any a priori knowledge on the impedance pattern, and starts from a mask constraint on the desired far-field and practical bounds on the unit cell impedance values. The designed reactance surface for broadside radiation exhibits a non conventional patterning; this highlights the merit of using an automated design process for a design well known to be challenging for analytical methods. The antenna is physically implemented with an array of metal strips with varying gap widths and simulation results show very good agreement with the predicted performance

    Beam scanning by liquid-crystal biasing in a modified SIW structure

    Get PDF
    A fixed-frequency beam-scanning 1D antenna based on Liquid Crystals (LCs) is designed for application in 2D scanning with lateral alignment. The 2D array environment imposes full decoupling of adjacent 1D antennas, which often conflicts with the LC requirement of DC biasing: the proposed design accommodates both. The LC medium is placed inside a Substrate Integrated Waveguide (SIW) modified to work as a Groove Gap Waveguide, with radiating slots etched on the upper broad wall, that radiates as a Leaky-Wave Antenna (LWA). This allows effective application of the DC bias voltage needed for tuning the LCs. At the same time, the RF field remains laterally confined, enabling the possibility to lay several antennas in parallel and achieve 2D beam scanning. The design is validated by simulation employing the actual properties of a commercial LC medium

    Bistatic sonar and a novel form of variable depth sonar

    Get PDF
    This thesis relates to the sonar system research undertaken for a Naval Requirement for proposals to improve the cost effectiveness of the defence of shipping against submarine attacks. Defence systems evolved as a function of the developing technology of the opposition which in this instance is the ability of a submarine to remain undetected below the sea surface while searching for, tracking and attacking its targets. An inherent problem for underwater detection with Escort Ships hull type sonars is its location on the air-sea interface with the need of a two-way propagation path to access the depth-range volume available to a submarine. As the power of an Escort's sonar is increased so is the size of ship, 5000 tons and more, to accommodate the optimum size of transducers required.Sonar system research at all times is a multi-discipline task and in this particular case was further broadened with a requirement to review the possibilities for sources of energy other than underwater acoustics. The research confirms the dominance of sonar for underwater detection and establishes the feasibility of a Bistatic Sonar concept which replaces the two-way propagation path of a hull type sonar with a one-way path, source-target-receiver with a variable depth directive towed line receiver on a small ship as a distant receiver. A second objective which became feasible with the development of an adequate towed source was a variable depth sonar which has now been produced by British Aerospace for a world market. A summary of the thesis is provided as an introduction to the subject matter of the different sections

    IMPROVED IMAGE QUALITY IN CONE-BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED INTERVENTIONS

    Get PDF
    In the past few decades, cone-beam computed tomography (CBCT) emerged as a rapidly developing imaging modality that provides single rotation 3D volumetric reconstruction with sub-millimeter spatial resolution. Compared to the conventional multi-detector CT (MDCT), CBCT exhibited a number of characteristics that are well suited to applications in image-guided interventions, including improved mechanical simplicity, higher portability, and lower cost. Although the current generation of CBCT has shown strong promise for high-resolution and high-contrast imaging (e.g., visualization of bone structures and surgical instrumentation), it is often believed that CBCT yields inferior contrast resolution compared to MDCT and is not suitable for soft-tissue imaging. Aiming at expanding the utility of CBCT in image-guided interventions, this dissertation concerns the development of advanced imaging systems and algorithms to tackle the challenges of soft-tissue contrast resolution. The presented material includes work encompassing: (i) a comprehensive simulation platform to generate realistic CBCT projections (e.g., as training data for deep learning approaches); (ii) a new projection domain statistical noise model to improve the noise-resolution tradeoff in model-based iterative reconstruction (MBIR); (iii) a novel method to avoid CBCT metal artifacts by optimization of the source-detector orbit; (iv) an integrated software pipeline to correct various forms of CBCT artifacts (i.e., lag, glare, scatter, beam hardening, patient motion, and truncation); (v) a new 3D reconstruction method that only reconstructs the difference image from the image prior for use in CBCT neuro-angiography; and (vi) a novel method for 3D image reconstruction (DL-Recon) that combines deep learning (DL)-based image synthesis network with physics-based models based on Bayesian estimation of the statical uncertainty of the neural network. Specific clinical challenges were investigated in monitoring patients in the neurological critical care unit (NCCU) and advancing intraoperative soft-tissue imaging capability in image-guided spinal and intracranial neurosurgery. The results show that the methods proposed in this work substantially improved soft-tissue contrast in CBCT. The thesis demonstrates that advanced imaging approaches based on accurate system models, novel artifact reduction methods, and emerging 3D image reconstruction algorithms can effectively tackle current challenges in soft-tissue contrast resolution and expand the application of CBCT in image-guided interventions

    Goddard Conference on Mass Storage Systems and Technologies, volume 2

    Get PDF
    Papers and viewgraphs from the conference are presented. Discussion topics include the IEEE Mass Storage System Reference Model, data archiving standards, high-performance storage devices, magnetic and magneto-optic storage systems, magnetic and optical recording technologies, high-performance helical scan recording systems, and low end helical scan tape drives. Additional discussion topics addressed the evolution of the identifiable unit for processing (file, granule, data set, or some similar object) as data ingestion rates increase dramatically, and the present state of the art in mass storage technology

    Remote Sensing for Wind Energy

    Get PDF

    Neural network modeling of a dolphin's sonar discrimination capabilities

    Get PDF
    • …
    corecore