806 research outputs found

    The latest applications of photoplethysmography

    Get PDF
    The development of medicine and the ability to conduct effective therapy in increasingly severe cases createthe need to develop new methods of continuous and non-invasive monitoring of the patient’s condition. One ofthe techniques that is widely used in many fields of medicine is photoplethysmography (PPG). The analysis ofthe latest research indicates that PPG can have much more applications than the measurement of heart rateand arterial saturation of the patient — as shown by the latest research, it can be used in the measurementof many other key parameters.The optimism is the multitude of areas in which PPG monitoring is attempted. There are more and more attemptsto use photoplethysmography in diagnosis and evaluation of peripheral vascular diseases, assessment ofcirculation in diabetic patients and assessment of endothelial function. Authors are focusing on new applicationsof PPG, its advantages and limitations. Most of them agree that PPG can provide useful knowledge about thepatient’s condition while being a quick, easy-to-use and cost-effective technique.The following review was created to critically analyze the latest technical developments and uses of PPG inclinical practice. Sources for the following article were found using the PubMed database using keywords suchas “photoplethysmography”, “oxygen saturation” and “pulse oximeter”

    Wearable technology and the cardiovascular system: the future of patient assessment

    Get PDF
    The past decade has seen a dramatic rise in consumer technologies able to monitor a variety of cardiovascular parameters. Such devices initially recorded markers of exercise, but now include physiological and health-care focused measurements. The public are keen to adopt these devices in the belief that they are useful to identify and monitor cardiovascular disease. Clinicians are therefore often presented with health app data accompanied by a diverse range of concerns and queries. Herein, we assess whether these devices are accurate, their outputs validated, and whether they are suitable for professionals to make management decisions. We review underpinning methods and technologies and explore the evidence supporting the use of these devices as diagnostic and monitoring tools in hypertension, arrhythmia, heart failure, coronary artery disease, pulmonary hypertension, and valvular heart disease. Used correctly, they might improve health care and support research

    Assessing mental stress from the photoplethysmogram: a numerical study.

    Get PDF
    OBJECTIVE: Mental stress is detrimental to cardiovascular health, being a risk factor for coronary heart disease and a trigger for cardiac events. However, it is not currently routinely assessed. The aim of this study was to identify features of the photoplethysmogram (PPG) pulse wave which are indicative of mental stress. APPROACH: A numerical model of pulse wave propagation was used to simulate blood pressure signals, from which simulated PPG pulse waves were estimated using a transfer function. Pulse waves were simulated at six levels of stress by changing the model input parameters both simultaneously and individually, in accordance with haemodynamic changes associated with stress. Thirty-two feature measurements were extracted from pulse waves at three measurement sites: the brachial, radial and temporal arteries. Features which changed significantly with stress were identified using the Mann-Kendall monotonic trend test. MAIN RESULTS: Seventeen features exhibited significant trends with stress in measurements from at least one site. Three features showed significant trends at all three sites: the time from pulse onset to peak, the time from the dicrotic notch to pulse end, and the pulse rate. More features showed significant trends at the radial artery (15) than the brachial (8) or temporal (7) arteries. Most features were influenced by multiple input parameters. SIGNIFICANCE: The features identified in this study could be used to monitor stress in healthcare and consumer devices. Measurements at the radial artery may provide superior performance than the brachial or temporal arteries. In vivo studies are required to confirm these observations

    Consumer-Led Screening for Atrial Fibrillation:A Report From the mAFA-II Trial Long-Term Extension Cohort

    Get PDF
    BACKGROUND: There are limited data on mobile health detection of prevalent atrial fibrillation (AF) and its related risk factors over time. OBJECTIVES: This study aimed to report the trends on prevalent AF detection over time and risk factors, with a consumer-led photoplethysmography screening approach. METHODS: 3,499,461 subjects aged over 18 years, who use smart devices (Huawei Technologies Co.) were enrolled between October 26, 2018, and December 1, 2021. RESULTS: Among 2,852,217 subjects for AF screening, 12,244 subjects (0.43%; 83.2% male, mean age 57 ± 15 years) detected AF episodes. When compared with 2018, the risk (adjusted HRs, 95% CI) for monitored prevalent AF increased significantly for subjects when monitoring started in 2020 (adjusted HR: 1.34; 95% CI: 1.27-1.40; P 93% confirmation of detected AF episodes even for the low-risk general population, highlighting the increased risk for detecting prevalent AF and the need for modification of OSA that increase AF susceptibility. (Mobile Health [mHealth] Technology for Improved Screening, Patient Involvement and Optimizing Integrated Care in Atrial Fibrillation [mAFA (mAF-App) II study]; ChiCTR-OOC-17014138

    Photoplethysmography upon cold stress — impact of measurement site and acquisition mode

    Get PDF
    Photoplethysmography (PPG) allows various statements about the physiological state. It supports multiple recording setups, i.e., application to various body sites and different acquisition modes, rendering the technique a versatile tool for various situations. Owing to anatomical, physiological and metrological factors, PPG signals differ with the actual setup. Research on such differences can deepen the understanding of prevailing physiological mechanisms and path the way towards improved or novel methods for PPG analysis. The presented work systematically investigates the impact of the cold pressor test (CPT), i.e., a painful stimulus, on the morphology of PPG signals considering different recording setups. Our investigation compares contact PPG recorded at the finger, contact PPG recorded at the earlobe and imaging PPG (iPPG), i.e., non-contact PPG, recorded at the face. The study bases on own experimental data from 39 healthy volunteers. We derived for each recording setup four common morphological PPG features from three intervals around CPT. For the same intervals, we derived blood pressure and heart rate as reference. To assess differences between the intervals, we used repeated measures ANOVA together with paired t-tests for each feature and we calculated Hedges’ g to quantify effect sizes. Our analyses show a distinct impact of CPT. As expected, blood pressure shows a highly significant and persistent increase. Independently of the recording setup, all PPG features show significant changes upon CPT as well. However, there are marked differences between recording setups. Effect sizes generally differ with the finger PPG showing the strongest response. Moreover, one feature (pulse width at half amplitude) shows an inverse behavior in finger PPG and head PPG (earlobe PPG and iPPG). In addition, iPPG features behave partially different from contact PPG features as they tend to return to baseline values while contact PPG features remain altered. Our findings underline the importance of recording setup and physiological as well as metrological differences that relate to the setups. The actual setup must be considered in order to properly interpret features and use PPG. The existence of differences between recording setups and a deepened knowledge on such differences might open up novel diagnostic methods in the future

    Sensitivity and specificity of the ankle–brachial index to diagnose peripheral artery disease: a structured review

    Get PDF
    The ankle—brachial index (ABI) is a simple, inexpensive diagnostic test for peripheral artery disease (PAD). However, it has shown variable accuracy for identification of significant stenosis. The authors performed a structured review of the sensitivity and specificity of ABI ≤ 0.90 for the diagnosis of PAD. MEDLINE, EMBASE, Cochrane databases, Science Citation Index database, and Biological Abstracts database were searched for studies of the sensitivity and specificity of using ABI ≤ 0.90 for the diagnosis of PAD. Eight studies comprising 2043 patients (or limbs) met the inclusion criteria. The result indicated that, although strict inclusion criteria on studies were formulated, different reference standards were found in these studies, and methods of ABI determination and characteristics of populations varied greatly. A high level of specificity (83.3—99.0%) and accuracy (72.1—89.2%) was reported for an ABI ≤ 0.90 in detecting ≥ 50% stenosis, but there were different levels of sensitivity (15—79%). Sensitivity was low, especially in elderly individuals and patients with diabetes. In conclusion, the test of ABI ≤ 0.90 can be a simple and useful tool to identify PAD with serious stenosis, and may be substituted for other non-invasive tests in clinical practice

    Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring

    Get PDF
    Photoplethysmography (PPG) is a low-cost, noninvasive optical technique that uses change in light transmission with changes in blood volume within tissue to provide information for cardiovascular health and fitness. As remote health and wearable medical devices become more prevalent, PPG devices are being developed as part of wearable systems to monitor parameters such as heart rate (HR) that do not require complex analysis of the PPG waveform. However, complex analyses of the PPG waveform yield valuable clinical information, such as: blood pressure, respiratory information, sympathetic nervous system activity, and heart rate variability. Systems aiming to derive such complex parameters do not always account for realistic sources of noise, as testing is performed within controlled parameter spaces. A wearable monitoring tool to be used beyond fitness and heart rate must account for noise sources originating from individual patient variations (e.g., skin tone, obesity, age, and gender), physiology (e.g., respiration, venous pulsation, body site of measurement, and body temperature), and external perturbations of the device itself (e.g., motion artifact, ambient light, and applied pressure to the skin). Here, we present a comprehensive review of the literature that aims to summarize these noise sources for future PPG device development for use in health monitoring
    • …
    corecore