3,196 research outputs found

    Correlation Based Method for Phase Identification in a Three Phase LV Distribution Network

    Get PDF
    Low voltage distribution networks feature a high degree of load unbalance and the addition of rooftop photovoltaic is driving further unbalances in the network. Single phase consumers are distributed across the phases but even if the consumer distribution was well balanced when the network was constructed changes will occur over time. Distribution transformer losses are increased by unbalanced loadings. The estimation of transformer losses is a necessary part of the routine upgrading and replacement of transformers and the identification of the phase connections of households allows a precise estimation of the phase loadings and total transformer loss. This paper presents a new technique and preliminary test results for a method of automatically identifying the phase of each customer by correlating voltage information from the utility's transformer system with voltage information from customer smart meters. The techniques are novel as they are purely based upon a time series of electrical voltage measurements taken at the household and at the distribution transformer. Experimental results using a combination of electrical power and current of the real smart meter datasets demonstrate the performance of our techniques

    Smart grid architecture for rural distribution networks: application to a Spanish pilot network

    Get PDF
    This paper presents a novel architecture for rural distribution grids. This architecture is designed to modernize traditional rural networks into new Smart Grid ones. The architecture tackles innovation actions on both the power plane and the management plane of the system. In the power plane, the architecture focuses on exploiting the synergies between telecommunications and innovative technologies based on power electronics managing low scale electrical storage. In the management plane, a decentralized management system is proposed based on the addition of two new agents assisting the typical Supervisory Control And Data Acquisition (SCADA) system of distribution system operators. Altogether, the proposed architecture enables operators to use more effectively—in an automated and decentralized way—weak rural distribution systems, increasing the capability to integrate new distributed energy resources. This architecture is being implemented in a real Pilot Network located in Spain, in the frame of the European Smart Rural Grid project. The paper also includes a study case showing one of the potentialities of one of the principal technologies developed in the project and underpinning the realization of the new architecture: the so-called Intelligent Distribution Power Router.Postprint (published version

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Experimental Investigation and Evaluation of Future Active Distribution Networks

    Get PDF
    The UK government’s policy to achieve a 20% renewable energy generation target by 2020, will require significant amounts of SSEG (Small-Scale Embedded Generation) to be connected. In addition to the expected economic and environmental benefits, the anticipated growth in SSEG brings with it numerous challenges for the operation of low voltage and medium voltage distribution networks. At present, there are a number of competing active network management concepts being considered to overcome these challenges and at Durham University a concept defined as the Small Scale Energy Zone (SSEZ) has been proposed and is investigated as part of this research. To further this, a bespoke active low voltage distribution network emulator known as the Experimental SSEZ has been developed by the author. Controllable emulated SSEG, controllable energy storage and controllable emulated load are incorporated into this laboratory. A transformation system has been developed to relate the operation of this system to that of low voltage distribution networks. Centralised and distributed network control systems have been developed for the Experimental SSEZ. These systems were used to evaluate, in conjunction with the relevant literature, the implementation of similar systems on future low voltage distribution networks. Both centralised and distributed control system architectures were found to have their merits. This research should therefore be useful in informing design decisions when developing and implementing active distribution network management systems on LV networks

    A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters

    Get PDF
    High impedance faults (HIFs) have been a major concern for protecting distribution systems and public safety hazards when involving downed conductors. The deployment of smarter grids brings new technologies for smart monitoring, automation, and protection of distribution networks. This paper presents a new method for a series of HIF detection and location in primary distribution feeders, using voltage unbalance measurements collected from smart meters (SMs) installed at low-voltage end-users. The methodology was tested in MATLAB and Simulink through steady-state simulations of a typical 13.8 kV distribution system, under load unbalance and di erent fault scenarios. Results show that the proposed method is robust and accurate for the detection of blown fuses and broken conductors, with or without ground faults, located either at the source or the load-side. The ease of implementation in SM design, formulation of parameters, and reliable simulation results show potential real-life applications

    Optimal Online Charging Coordination of Plug in Electric Vehicles in Unbalanced Grids for Ancillary Voltage Support

    Get PDF
    This PhD thesis will propose an optimal online charge control through genetic algorithm for G2V coordination of PEVs (OL-C-TP) in unbalanced systems. Moreover the algorithm will be extended to also include V2G coordination and offer ancillary voltage support (OL-CD-TPQ) by considering two different methods based on the utility time-of-day prices for exporting reactive power and droop controller for decentralized exporting of reactive power. Then the performance of OL-CD-TPQ by switching PEVs in three phase unbalanced networks is improved

    Phase unbalance on low-voltage electricity networks and its mitigation using static balancers

    Get PDF
    Existing low-voltage networks may not accommodate high penetrations of low-carbon technologies. The topic of this thesis is unbalance, which if minimised can delay or avoid the constraining of these technologies or the replacing of still-useful network assets. Most of the discussion on unbalance, as seen in the standards and the literature, centres on the effects of voltage unbalance on consumer equipment. Its effects on the network are not equally reported. This thesis recognises fundamental differences between the consumer and network perspectives. It can inform distribution network operators on the interpretation of measurements taken on low-voltage networks and guide research on unbalance due to high penetrations of low-carbon technologies. Much of the work involved simulations of LV networks. Initially, existing 3 x 3 or 5 x 5 approaches to the forward-backward sweep method were thought suitable. After a review of these approaches however, there were doubts as to how accurately they accounted for the shared neutral-earth return path on which the out-of-balance current flows. This led to the derivation of a new 5 x 5 approach using only Kirchhoff s voltage (KVL) and current laws (KCL). Its results are validated thoroughly in the thesis. In addition to satisfying KVL and KCL, they match Matlab SimPowerSystems exactly and are in close agreement with measurements taken on a very unbalanced rural feeder. This thesis also investigates the mitigation of unbalance using the static balancer. This is a transformer with a single interconnected-star winding. It was used in 1930-1950s to correct unbalance. Contributions are made for its possible re-introduction as a retrofit option. They include a model for use in the forward-backward sweep method, validated by laboratory and field measurements, and the quantification of the static balancer s strengths and weaknesses as this can help identify when it should be used

    Modelling and analysis of demand response implementation in the residential sector

    Get PDF
    Demand Response (DR) eliminates the need for expensive capital expenditure on the electricity distribution, transmission and the generation systems by encouraging consumers to alter their power usage through electricity pricing or incentive programs. However, modelling of DR programs for residential consumers is complicated due to the uncertain consumption behavious of consumers and the complexity of schedulling a large number of household appliances. This thesis has investigated the design and the implementation challenges of the two most commonly used DR components in the residential sector, i.e., time of use (TOU) and direct load control (DLC) programs for improving their effectiveness and implementation with innovative strategies to facilitate their acceptance by both consumers and utilities. In price-based DR programs, the TOU pricing scheme is one of the most attractive and simplest approaches for reducing peak electricity demand in the residential sector. This scheme has been adopted in many developed countries because it requires less communication infrastructure for its implementation. However, the implementation of TOU pricing in low and lower-middle income economies is less appealing, mainly due to a large number of low-income consumers, as traditional TOU pricing schemes may increase the cost of electricity for low income residential consumers and adversely affect their comfort levels. The research in this thesis proposes an alternative TOU pricing strategy for the residential sector in developing countries in order to manage peak demand problems while ensuring a low impact on consumers’ monthly energy bills and comfort levels. In this study, Bangladesh is used as an example of a lower-to-middle income developing country. The DLC program is becoming an increasingly attractive solution for utilities in developed countries due to advances in the construction of communication infrastructures as part of the smart grid concept deployment. One of the main challenges of the DLC program implementation is ensuring optimal control over a large number of different household appliances for managing both short and long intervals of voltage variation problems in distribution networks at both medium voltage (MV) and low voltage (LV) networks, while simultaneously enabling consumers to maintain their comfort levels. Another important challenge for DLC implementation is achieving a fair distribution of incentives among a large number of participating consumers. This thesis addresses these challenges by proposing a multi-layer load control algorithm which groups the household appliances based on the intervals of the voltage problems and coordinates with the reactive power from distributed generators (DGs) for the effective voltage management in MV networks. The proposed load controller takes into consideration the consumption preference of individual appliance, ensuring that the consumer’s comfort level is satisfied as well as fairly incentivising consumers based on their contributions in network voltage and power loss improvement. Another significant challenge with the existing DLC strategy as it applies to managing voltage in LV networks is that it does not take into account the network’s unbalance constraints in the load control algorithm. In LV distribution networks, voltage unbalance is prevalent and is one of the main power quality problems of concern. Unequal DR activation among the phases may cause excessive voltage unbalance in the network. In this thesis, a new load control algorithm is developed with the coordination of secondary on-load tap changer (OLTC) transformer for effective management of both voltage magnitude and unbalance in the LV networks. The proposed load control algorithm minimises the disturbance to consumers’ comfort levels by prioritising their consumption preferences. It motivates consumers to participate in DR program by providing flexibility to bid their participation prices dynamically in each DR event. The proposed DR programs are applicable for both developed and developing countries based on their available communication infrastructure for DR implementation. The main benefits of the proposed DR programs can be shared between consumers and their utilities. Consumers have flexibility in being able to prioritise their comfort levels and bid for their participation prices or receive fair incentives, while utilities effectively manage their network peak demand and power quality problems with minimum compensation costs. As a whole, consumers get the opportunity to minimise their electricity bills while utilities are able to defer or avoid the high cost of their investment in network reinforcements

    Continuous harmonic analysis and power quality measurements in three-phase systems

    Get PDF
    A virtual instrument, named Power Quality Meter, is presented for (a) measuring power consumption and harmonics in three-phase systems, under non-sinusoidal and imbalance conditions (b) detecting, classifying and organizes power disturbance events. Measurement of the power consumption follows the formulation proposed by the members of the IEEE Working Group on Nonsinusoidal Situations (1996). So, definitions are based on the analysis of functions in the frequency domain, separating the fundamental terms from the harmonic terms of the Fourier series. The virtual instrument has been developed too for monitoring and measuring power disturbances, which are automatically classified and organized in a database while they are being recorded. Software tools use the database structure to present summaries of power disturbances and locate an event by severity or time of occurrence. Records of actual measurements are included to demonstrate the versatility of the instrument

    Multi Agent Systems for the Active Management of Electrical Distribution Networks

    Get PDF
    This Thesis presents an investigation on the technical impacts caused by the steady state operation of Small-Scale Embedded Generators (SSEGs) and also introduces the Small Scale Energy Zone (SSEZ) concept which aims to remove the technical barriers associated with SSEGs through intelligent coordination of large numbers of customerowned SSEGs, energy storage units and controllable loads. This approach represents a move away from the conventional passive, “fit-and-forget” philosophy under which the majority of Low Voltage (LV) distribution networks are currently operated and towards a higher degree of network operational management. The employment of a distributed management and control approach for an SSEZ, realised through the Multi Agent Systems (MAS) technology, is proposed due to the advantages that can potentially be realised in the areas of: (i) scalability and openness, (ii) reliability and resilience and (iii) communications efficiency. A FIPA-compliant MAS-based control approach is designed, developed and evaluated based on the specific SSEZ control requirements. The MAS is composed of three types of agents: direct control agents, indirect control agents and utility agents, exchanging information through the employment of a common ontology. In addition, a relational database management system is also designed and developed in order to be coupled with the developed MAS for data management purposes
    • 

    corecore