    Analysis of electrical power data for condition monitoring of a small wind turbine

    Get PDF
    Certain parts of a wind turbine, for example, the gearbox require significant time and heavy lifting equipment in the event of catastrophic failure necessitating replacement. Continuous condition monitoring has the potential to catch problems early, enable scheduled preventative maintenance and thereby reduce turbine downtime, reduce the number of site visits and prevent secondary damage. Accelerometers applied to mechanical components of the drive train are traditionally used for condition monitoring but require their own data acquisition system and analysis software. In contrast, the electrical current and voltage are continuously measured and could also be used for condition monitoring more cheaply. An experimental data acquisition system has been installed on a small (25kW) onshore turbine in Leicestershire, UK to compare three-phase currents and voltages on the stator windings with six accelerometer signals. Data have been recorded before and after a gearbox failure and replacement. Data were analysed using both Fourier Transform and Morlet Continuous Wavelet Transform methods. Results show that the stator voltages show the same radial and axial mode vibration frequencies as the accelerometers and could therefore be used for condition monitoring. Furthermore, the stator currents show torsional modes of vibration not picked up by the accelerometers

    Program latihan industri di Kolej Universiti Teknologi Tun Hussein Onn : kajian terhadap perlaksanaan sistem penilaian

    Get PDF
    Kajian yang dijalankan adalah bertajuk "Program Lalilian lndustri Di Kolej Universiti Teknologi Tun Hussein Onn : Kajian Terhadap Perlaksanaan Sistem Penilaian". Sampel terdin daripada 6 orang pakar serta 63 orang pelajar yang terlibat dalam latihan industri. Maklumat yang diperolehi berdasarkan kaedah kualitatif dan kuantitatif Data dianalisis untuk meninjau kaedah penilaian yang dijalankan dan seterusnya memastikan apakali sistem penilaian yang perlu diperbaiki. Secara keseluruhannya, kebanyakan responden berpendapat bahawa sistem penilaian yang sedia ada adalah perlu diperbaki dan disistematikkan selaras dengan ISO 9000 : 2001. Berdasarkan daripada keputusan yang diperolehi dan bimbingnan pakar dari Unit Latihan lndustri KUiTTHO, maka satu "Buku Panduan Penilaian Latihan lndustri" dihasilkan dengan panduan yang ringkas dan lampiran borang-borang yang telah diperbaiki dan diubahsuai. Diharapkan produk mi dapat digunakan untuk masa-masa akan datang

    Use of Machine Learning for Partial Discharge Discrimination

    No full text
    Partial discharge (PD) measurements are an important tool for assessing the condition of power equipment. Different sources of PD have different effects on the insulation performance of power apparatus. Therefore, discrimination between PD sources is of great interest to both system utilities and equipment manufacturers. This paper investigates the use of a wide bandwidth PD on-line measurement system to facilitate automatic PD source identification. Three artificial PD models were used to simulate typical PD sources which may exist within power systems. Wavelet analysis was applied to pre-process the obtained measurement data. This data was then processed using correlation analysis to cluster the discharges into different groups. A machine learning technique, namely the support vector machine (SVM) was then used to identify between the different PD sources. The SVM is trained to differentiate between the inherent features of each discharge source signal. Laboratory experiments indicate that this approach is applicable for use with field measurement data

    Time domain analysis of switching transient fields in high voltage substations

    Get PDF
    Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within the substations. The radiated fields may interfere and disrupt normal operations of electronic equipment used within the substation for measurement, control and communication purposes. Hence there is the need to fully characterise the substation electromagnetic environment as early as the design stage of substation planning and operation to ensure safe operations of the electronic equipment. This paper deals with the computation of transient electromagnetic fields due to switching within a high voltage air-insulated substation (AIS) using the finite difference time domain (FDTD) metho

    Multiple bottlenecks sorting criterion at initial sequence in solving permutation flow shop scheduling problem

    Get PDF
    This paper proposes a heuristic that introduces the application of bottleneck-based concept at the beginning of an initial sequence determination with the objective of makespan minimization. Earlier studies found that the scheduling activity become complicated when dealing with machine, m greater than 2, known as non-deterministic polynomial-time hardness (NP-hard). To date, the Nawaz-Enscore-Ham (NEH) algorithm is still recognized as the best heuristic in solving makespan problem in scheduling environment. Thus, this study treated the NEH heuristic as the highest ranking and most suitable heuristic for evaluation purpose since it is the best performing heuristic in makespan minimization. This study used the bottleneck-based approach to identify the critical processing machine which led to high completion time. In this study, an experiment involving machines (m =4) and n-job (n = 6, 10, 15, 20) was simulated in Microsoft Excel Simple Programming to solve the permutation flowshop scheduling problem. The overall computational results demonstrated that the bottleneck machine M4 performed the best in minimizing the makespan for all data set of problems

    Condition Monitoring of Power Cables

    No full text
    A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, funded through the EPSRC Supergen V, UK Energy Infrastructure (AMPerES) grant in collaboration with UK electricity network operators has concentrated on the development of partial discharge data processing techniques that ultimately may allow continuous assessment of transmission asset health to be reliably determined

    Fault Detection of Gearbox from Inverter Signals Using Advanced Signal Processing Techniques

    Get PDF
    The gear faults are time-localized transient events so time-frequency analysis techniques (such as the Short-Time Fourier Transform, Wavelet Transform, motor current signature analysis) are widely used to deal with non-stationary and nonlinear signals. Newly developed signal processing techniques (such as empirical mode decomposition and Teager Kaiser Energy Operator) enabled the recognition of the vibration modes that coexist in the system, and to have a better understanding of the nature of the fault information contained in the vibration signal. However these methods require a lot of computational power so this paper presents a novel approach of gearbox fault detection using the inverter signals to monitor the load, rather than the motor current. The proposed technique could be used for continuous monitoring as well as on-line damage detection systems for gearbox maintenance

    Partial discharge pulse propagation in power cable and partial discharge monitoring system

    Get PDF
    Partial discharge (PD) based condition monitoring has been widely applied to power cables. However, difficulties in interpretation of measurement results (location and criticality) remain to be tackled. This paper aims to develop further knowledge in PD signal propagation in power cables and attenuation by the PD monitoring system devices to address the localization and criticality issues. As on-line or in-service PD monitoring sensors commonly comprise of a high frequency current transformer (HFCT) and a high-pass filter, the characteristics of detected PD pulses depend on the attenuation of the cable, the HFCT used and the filter applied. Simulation of pulse propagation in a cable and PD monitoring system are performed, based on analyses in the frequency domain using the concept of transfer functions. Results have been verified by laboratory experiments and using on-site PD measurements. The knowledge gained from the research on the change in pulse characteristics propagating in a cable and through a PD detection system can be very useful to PD denoising and for development of a PD localization technique

    Imaging time series for the classification of EMI discharge sources

    Get PDF
    In this work, we aim to classify a wider range of Electromagnetic Interference (EMI) discharge sources collected from new power plant sites across multiple assets. This engenders a more complex and challenging classification task. The study involves an investigation and development of new and improved feature extraction and data dimension reduction algorithms based on image processing techniques. The approach is to exploit the Gramian Angular Field technique to map the measured EMI time signals to an image, from which the significant information is extracted while removing redundancy. The image of each discharge type contains a unique fingerprint. Two feature reduction methods called the Local Binary Pattern (LBP) and the Local Phase Quantisation (LPQ) are then used within the mapped images. This provides feature vectors that can be implemented into a Random Forest (RF) classifier. The performance of a previous and the two new proposed methods, on the new database set, is compared in terms of classification accuracy, precision, recall, and F-measure. Results show that the new methods have a higher performance than the previous one, where LBP features achieve the best outcome
    • 