77 research outputs found

    Photoplethysmography-Based Biomedical Signal Processing

    Get PDF
    In this dissertation, photoplethysmography-based biomedical signal processing methods are developed and analyzed. The developed methods solve problems concerning the estimation of the heart rate during physical activity and the monitoring of cardiovascular health. For the estimation of heart rate during physical activity, two methods are presented that are very accurate in estimating the instantaneous heart rate at the wrist and, at the same time, are computationally efficient so that they can easily be integrated into wearables. In the context of cardiovascular health monitoring, a method for the detection of atrial fibrillation using the video camera of a smartphone is proposed that achieves a high detection rate of atrial fibrillation (AF) on a clinical pre-study data set. Further monitoring of cardiovascular parameters includes the estimation of blood pressure (BP), pulse wave velocity (PWV), and vascular age index (VAI), for which an approach is presented that requires only a single photoplethysmographic (PPG) signal. Heart rate estimation during physical activity using PPG signals constitutes an important research focus of this thesis. In this work, two computationally efficient algorithms are presented that estimate the heart rate from two PPG signals using a three axis accelerometer. In the first approach, adaptive filters are applied to estimate motion artifacts that severely deteriorate the signal quality. The non-stationary relationship between the measured acceleration signals and the artifacts is modeled as a linear system. The outputs of the adaptive filters are combined to further enhance the signal quality and a constrained heart rate tracker follows the most probable high energy continuous line in the spectral domain. The second approach is modest in computational complexity and very fast in execution compared to existing approaches. It combines correlation-based fundamental frequency indicating functions and spectral combination to enhance the correlated useful signal and suppress uncorrelated noise. Additional harmonic noise damping further reduces the impact of strong motion artifacts and a spectral tracking procedure uses a linear least squares prediction. Both approaches are modest in computational complexity and especially the second approach is very fast in execution, as it is shown on a widely used benchmark data set and compared to state-of-the-art methods. The second research focus and a further major contribution of this thesis lies in the monitoring of the cardiovascular health with a single PPG signal. Two methods are presented, one for detection of AF and one for the estimation of BP, PWV, and VAI. The first method is able to detect AF based on a smartphone filming the finger placed on the video camera. The algorithm transforms the video into a PPG signal and extracts features which are then used to discriminate between AF and normal sinus rhythm (NSR). Perfect detection of AF is already achieved on a data set of 326 measurements (including 20 with AF) that were taken at a clinical pre-study using an appropriate pair of features whereby a decision is formed through a simple linear decision equation. The second method aims at estimating cardiovascular parameters from a single PPG signal without the conventional use of an additional electrocardiogram (ECG). The proposed method extracts a large number of features from the PPG signal and its first and second order difference series, and reconstructs missing features by the use of matrix completion. The estimation of cardiovascular parameters is based on a nonlinear support vector regression (SVR) estimator and compared to single channel PPG based estimators using a linear regression model and a pulse arrival time (PAT) based method. If the training data set contains the person for whom the cardiovascular parameters are to be determined, the proposed method can provide an accurate estimate without further calibration. All proposed algorithms are applied to real data that we have either recorded ourselves in our biomedical laboratory, that have been recorded by a clinical research partner, or that are freely available as benchmark data sets

    The 2023 wearable photoplethysmography roadmap

    Get PDF
    Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology

    Video pulse rate variability analysis in stationary and motion conditions

    Get PDF
    Background: In the last few years, some studies have measured heart rate (HR) or heart rate variability (HRV) parameters using a video camera. This technique focuses on the measurement of the small changes in skin colour caused by blood perfusion. To date, most of these works have obtained HRV parameters in stationary conditions, and there are practically no studies that obtain these parameters in motion scenarios and by conducting an in-depth statistical analysis. Methods: In this study, a video pulse rate variability (PRV) analysis is conducted by measuring the pulse-to-pulse (PP) intervals in stationary and motion conditions. Firstly, given the importance of the sampling rate in a PRV analysis and the low frame rate of commercial cameras, we carried out an analysis of two models to evaluate their performance in the measurements. We propose a selective tracking method using the Viola–Jones and KLT algorithms, with the aim of carrying out a robust video PRV analysis in stationary and motion conditions. Data and results of the proposed method are contrasted with those reported in the state of the art. Results: The webcam achieved better results in the performance analysis of video cameras. In stationary conditions, high correlation values were obtained in PRV parameters with results above 0.9. The PP time series achieved an RMSE (mean ± standard deviation) of 19.45 ± 5.52 ms (1.70 ± 0.75 bpm). In the motion analysis, most of the PRV parameters also achieved good correlation results, but with lower values as regards stationary conditions. The PP time series presented an RMSE of 21.56 ± 6.41 ms (1.79 ± 0.63 bpm). Conclusions: The statistical analysis showed good agreement between the reference system and the proposed method. In stationary conditions, the results of PRV parameters were improved by our method in comparison with data reported in related works. An overall comparative analysis of PRV parameters in motion conditions was more limited due to the lack of studies or studies containing insufficient data analysis. Based on the results, the proposed method could provide a low-cost, contactless and reliable alternative for measuring HR or PRV parameters in non-clinical environments.Peer ReviewedPostprint (published version

    Multi-layered Cepstrum for Instantaneous Frequency Estimation

    Get PDF
    We propose the multi-layered cepstrum (MLC) method to estimate multiple fundamental frequencies (MF0) of a signal under challenging contamination such as high-pass filter noise. Taking the operation of cepstrum (i.e., Fourier transform, filtering, and nonlinear activation) recursively, MLC is shown as an efficient method to enhance MF0 saliency in a step-by-step manner. Evaluation on a real-world polyphonic music dataset under both normal and low-fidelity conditions demonstrates the potential of MLC.Comment: In 2018 6th IEEE Global Conference on Signal and Information Processin

    PPG-based Heart Rate Estimation with Efficient Sensor Sampling and Learning Models

    Full text link
    Recent studies showed that Photoplethysmography (PPG) sensors embedded in wearable devices can estimate heart rate (HR) with high accuracy. However, despite of prior research efforts, applying PPG sensor based HR estimation to embedded devices still faces challenges due to the energy-intensive high-frequency PPG sampling and the resource-intensive machine-learning models. In this work, we aim to explore HR estimation techniques that are more suitable for lower-power and resource-constrained embedded devices. More specifically, we seek to design techniques that could provide high-accuracy HR estimation with low-frequency PPG sampling, small model size, and fast inference time. First, we show that by combining signal processing and ML, it is possible to reduce the PPG sampling frequency from 125 Hz to only 25 Hz while providing higher HR estimation accuracy. This combination also helps to reduce the ML model feature size, leading to smaller models. Additionally, we present a comprehensive analysis on different ML models and feature sizes to compare their accuracy, model size, and inference time. The models explored include Decision Tree (DT), Random Forest (RF), K-nearest neighbor (KNN), Support vector machines (SVM), and Multi-layer perceptron (MLP). Experiments were conducted using both a widely-utilized dataset and our self-collected dataset. The experimental results show that our method by combining signal processing and ML had only 5% error for HR estimation using low-frequency PPG data. Moreover, our analysis showed that DT models with 10 to 20 input features usually have good accuracy, while are several magnitude smaller in model sizes and faster in inference time
    • …
    corecore