323 research outputs found

    Development of Digital Control Systems for Wearable Mechatronic Devices: Applications in Musculoskeletal Rehabilitation of the Upper Limb

    Get PDF
    The potential for wearable mechatronic systems to assist with musculoskeletal rehabilitation of the upper limb has grown with the technology. One limiting factor to realizing the benefits of these devices as motion therapy tools is within the development of digital control solutions. Despite many device prototypes and research efforts in the surrounding fields, there are a lack of requirements, details, assessments, and comparisons of control system characteristics, components, and architectures in the literature. Pairing this with the complexity of humans, the devices, and their interactions makes it a difficult task for control system developers to determine the best solution for their desired applications. The objective of this thesis is to develop, evaluate, and compare control system solutions that are capable of tracking motion through the control of wearable mechatronic devices. Due to the immaturity of these devices, the design, implementation, and testing processes for the control systems is not well established. In order to improve the efficiency and effectiveness of these processes, control system development and evaluation tools have been proposed. The Wearable Mechatronics-Enabled Control Software framework was developed to enable the implementation and comparison of different control software solutions presented in the literature. This framework reduces the amount of restructuring and modification required to complete these development tasks. An integration testing protocol was developed to isolate different aspects of the control systems during testing. A metric suite is proposed that expands on the existing literature and allows for the measurement of more control characteristics. Together, these tools were used ii ABSTRACT iii to developed, evaluate, and compare control system solutions. Using the developed control systems, a series of experiments were performed that involved tracking elbow motion using wearable mechatronic elbow devices. The accuracy and repeatability of the motion tracking performances, the adaptability of the control models, and the resource utilization of the digital systems were measured during these experiments. Statistical analysis was performed on these metrics to compare between experimental factors. The results of the tracking performances show some of the highest accuracies for elbow motion tracking with these devices. The statistical analysis revealed many factors that significantly impact the tracking performance, such as visual feedback, motion training, constrained motion, motion models, motion inputs, actuation components, and control outputs. Furthermore, the completion of the experiments resulted in three first-time studies, such as the comparison of muscle activation models and the quantification of control system task timing and data storage needs. The successes of these experiments highlight that accurate motion tracking, using biological signals of the user, is possible, but that many more efforts are needed to obtain control solutions that are robust to variations in the motion and characteristics of the user. To guide the future development of these control systems, a national survey was conducted of therapists regarding their patient data collection and analysis methods. From the results of this survey, a series of requirements for software systems, that allow therapists to interact with the control systems of these devices, were collected. Increasing the participation of therapists in the development processes of wearable assistive devices will help to produce better requirements for developers. This will allow the customization of control systems for specific therapies and patient characteristics, which will increase the benefit and adoption rate of these devices within musculoskeletal rehabilitation programs

    Mechatronic Systems

    Get PDF
    Mechatronics, the synergistic blend of mechanics, electronics, and computer science, has evolved over the past twenty five years, leading to a novel stage of engineering design. By integrating the best design practices with the most advanced technologies, mechatronics aims at realizing high-quality products, guaranteeing at the same time a substantial reduction of time and costs of manufacturing. Mechatronic systems are manifold and range from machine components, motion generators, and power producing machines to more complex devices, such as robotic systems and transportation vehicles. With its twenty chapters, which collect contributions from many researchers worldwide, this book provides an excellent survey of recent work in the field of mechatronics with applications in various fields, like robotics, medical and assistive technology, human-machine interaction, unmanned vehicles, manufacturing, and education. We would like to thank all the authors who have invested a great deal of time to write such interesting chapters, which we are sure will be valuable to the readers. Chapters 1 to 6 deal with applications of mechatronics for the development of robotic systems. Medical and assistive technologies and human-machine interaction systems are the topic of chapters 7 to 13.Chapters 14 and 15 concern mechatronic systems for autonomous vehicles. Chapters 16-19 deal with mechatronics in manufacturing contexts. Chapter 20 concludes the book, describing a method for the installation of mechatronics education in schools

    Advances of Italian Machine Design

    Get PDF
    This 2028 Special Issue presents recent developments and achievements in the field of Mechanism and Machine Science coming from the Italian community with international collaborations and ranging from theoretical contributions to experimental and practical applications. It contains selected contributions that were accepted for presentation at the Second International Conference of IFToMM Italy, IFIT2018, that has been held in Cassino on 29 and 30 November 2018. This IFIT conference is the second event of a series that was established in 2016 by IFToMM Italy in Vicenza. IFIT was established to bring together researchers, industry professionals and students, from the Italian and the international community in an intimate, collegial and stimulating environment

    Design of a shape memory alloy actuator for soft wearable robots

    Get PDF
    Soft robotics represents a paradigm shift in the design of conventional robots; while the latter are designed as monolithic structures, made of rigid materials and normally composed of several stiff joints, the design of soft robots is based on the use of deformable materials such as polymers, fluids or gels, resulting in a biomimetic design that replicates the behavior of organic tissues. The introduction of this design philosophy into the field of wearable robots has transformed them from rigid and cumbersome devices into something we could call exo-suits or exo-musculatures: motorized, lightweight and comfortable clothing-like devices. If one thinks of the ideal soft wearable robot (exoskeleton) as a piece of clothing in which the actuation system is fully integrated into its fabrics, we consider that that existing technologies currently used in the design of these devices do not fully satisfy this premise. Ultimately, these actuation systems are based on conventional technologies such as DC motors or pneumatic actuators, which due to their volume and weight, prevent a seamless integration into the structure of the soft exoskeleton. The aim of this thesis is, therefore, to design of an actuator that represents an alternative to the technologies currently used in the field of soft wearable robotics, after having determined the need for an actuator for soft exoskeletons that is compact, flexible and lightweight, while also being able to produce the force required to move the limbs of a human user. Since conventional actuation technologies do not allow the design of an actuator with the required characteristics, the proposed actuator design has been based on so-called emerging actuation technologies, more specifically, on shape memory alloys (SMA). The mechanical design of the actuator is based on the Bowden transmission system. The SMA wire used as the transducer of the actuator has been routed into a flexible sheath, which, in addition to being easily adaptable to the user's body, increases the actuation bandwidth by reducing the cooling time of the SMA element by 30 %. At its nominal operating regime, the actuator provides an output displacement of 24 mm and generates a force of 64 N. Along with the actuator, a thermomechanical model of its SMA transducer has been developed to simulate its complex behavior. The developed model is a useful tool in the design process of future SMA-based applications, accelerating development ix time and reducing costs. The model shows very few discrepancies with respect to the behavior of a real wire. In addition, the model simulates characteristic phenomena of these alloys such as thermal hysteresis, including internal hysteresis loops and returnpoint memory, the dependence between transformation temperatures and applied force, or the effects of latent heat of transformation on the wire heating and cooling processes. To control the actuator, the use of a non-linear control technique called four-term bilinear proportional-integral-derivative controller (BPID) is proposed. The BPID controller compensates the non-linear behavior of the actuator caused by the thermal hysteresis of the SMA. Compared to the operation of two other implemented controllers, the BPID controller offers a very stable and robust performance, minimizing steady-state errors and without the appearance of limit cycles or other effects associated with the control of these alloys. To demonstrate that the proposed actuator together with the BPID controller are a valid solution for implementing the actuation system of a soft exoskeleton, both developments have been integrated into a real soft hand exoskeleton, designed to provide force assistance to astronauts. In this case, in addition to using the BPID controller to control the position of the actuators, it has been applied to the control of the assistive force provided by the exoskeleton. Through a simple mechanical multiplication mechanism, the actuator generates a linear displacement of 54 mm and a force of 31 N, thus fulfilling the design requirements imposed by the application of the exoskeleton. Regarding the control of the device, the BPID controller is a valid control technique to control both the position and the force of a soft exoskeleton using an actuation system based on the actuator proposed in this thesis.La robótica flexible (soft robotics) ha supuesto un cambio de paradigma en el diseño de robots convencionales; mientras que estos consisten en estructuras monolíticas, hechas de materiales duros y normalmente compuestas de varias articulaciones rígidas, el diseño de los robots flexibles se basa en el uso de materiales deformables como polímeros, fluidos o geles, resultando en un diseño biomimético que replica el comportamiento de los tejidos orgánicos. La introducción de esta filosofía de diseño en el campo de los robots vestibles (wearable robots) ha hecho que estos pasen de ser dispositivos rígidos y pesados a ser algo que podríamos llamar exo-trajes o exo-musculaturas: prendas de vestir motorizadas, ligeras y cómodas. Si se piensa en el robot vestible (exoesqueleto) flexible ideal como una prenda de vestir en la que el sistema de actuación está totalmente integrado en sus tejidos, consideramos que las tecnologías existentes que se utilizan actualmente en el diseño de estos dispositivos no satisfacen plenamente esta premisa. En última instancia, estos sistemas de actuaci on se basan en tecnologías convencionales como los motores de corriente continua o los actuadores neumáticos, que debido a su volumen y peso, hacen imposible una integraci on completa en la estructura del exoesqueleto flexible. El objetivo de esta tesis es, por tanto, el diseño de un actuador que suponga una alternativa a las tecnologias actualmente utilizadas en el campo de los exoesqueletos flexibles, tras haber determinado la necesidad de un actuador para estos dispositivos que sea compacto, flexible y ligero, y que al mismo tiempo sea capaz de producir la fuerza necesaria para mover las extremidades de un usuario humano. Dado que las tecnologías de actuación convencionales no permiten diseñar un actuador de las características necesarias, se ha optado por basar el diseño del actuador propuesto en las llamadas tecnologías de actuación emergentes, en concreto, en las aleaciones con memoria de forma (SMA). El diseño mecánico del actuador está basado en el sistema de transmisión Bowden. El hilo de SMA usado como transductor del actuador se ha introducido en una funda flexible que, además de adaptarse facilmente al cuerpo del usuario, aumenta el ancho de banda de actuación al reducir un 30 % el tiempo de enfriamiento del elemento SMA. En su régimen nominal de operaci on, el actuador proporciona un desplazamiento de salida de 24 mm y genera una fuerza de 64 N. Además del actuador, se ha desarrollado un modelo termomecánico de su transductor SMA que permite simular su complejo comportamiento. El modelo desarrollado es una herramienta útil en el proceso de diseño de futuras aplicaciones basadas en SMA, acelerando el tiempo de desarrollo y reduciendo costes. El modelo muestra muy pocas discrepancias con respecto al comportamiento de un hilo real. Además, es capaz de simular fenómenos característicos de estas aleaciones como la histéresis térmica, incluyendo los bucles internos de histéresis y la memoria de puntos de retorno (return-point memory), la dependencia entre las temperaturas de transformacion y la fuerza aplicada, o los efectos del calor latente de transformación en el calentamiento y el enfriamiento del hilo. Para controlar el actuador, se propone el uso de una t ecnica de control no lineal llamada controlador proporcional-integral-derivativo bilineal de cuatro términos (BPID). El controlador BPID compensa el comportamiento no lineal del actuador causado por la histéresis térmica del SMA. Comparado con el funcionamiento de otros dos controladores implementados, el controlador BPID ofrece un rendimiento muy estable y robusto, minimizando el error de estado estacionario y sin la aparición de ciclos límite u otros efectos asociados al control de estas aleaciones. Para demostrar que el actuador propuesto junto con el controlador BPID son una soluci on válida para implementar el sistema de actuación de un exoesqueleto flexible, se han integrado ambos desarrollos en un exoesqueleto flexible de mano real, diseñado para proporcionar asistencia de fuerza a astronautas. En este caso, además de utilizar el controlador BPID para controlar la posición de los actuadores, se ha aplicado al control de la fuerza proporcionada por el exoesqueleto. Mediante un simple mecanismo de multiplicación mecánica, el actuador genera un desplazamiento lineal de 54 mm y una fuerza de 31 N, cumpliendo así con los requisitos de diseño impuestos por la aplicación del exoesqueleto. Respecto al control del dispositivo, el controlador BPID es una técnica de control válida para controlar tanto la posición como la fuerza de un exoesqueleto flexible que use un sistema de actuación basado en el actuador propuesto en esta tesis.Programa de Doctorado en Ingeniería Eléctrica, Electrónica y Automática por la Universidad Carlos III de MadridPresidente: Fabio Bonsignorio.- Secretario: Concepción Alicia Monje Micharet.- Vocal: Elena García Armad

    Development of a Wearable Mechatronic Elbow Brace for Postoperative Motion Rehabilitation

    Get PDF
    This thesis describes the development of a wearable mechatronic brace for upper limb rehabilitation that can be used at any stage of motion training after surgical reconstruction of brachial plexus nerves. The results of the mechanical design and the work completed towards finding the best torque transmission system are presented herein. As part of this mechatronic system, a customized control system was designed, tested and modified. The control strategy was improved by replacing a PID controller with a cascade controller. Although the experiments have shown that the proposed device can be successfully used for muscle training, further assessment of the device, with the help of data from the patients with brachial plexus injury (BPI), is required to improve the control strategy. Unique features of this device include the combination of adjustability and modularity, as well as the passive adjustment required to compensate for the carrying angle

    A Wearable Mechatronic Device for Hand Tremor Monitoring and Suppression: Development and Evaluation

    Get PDF
    Tremor, one of the most disabling symptoms of Parkinson\u27s disease (PD), significantly affects the quality of life of the individuals who suffer from it. These people live with difficulties with fine motor tasks, such as eating and writing, and suffer from social embarrassment. Traditional medicines are often ineffective, and surgery is highly invasive and risky. The emergence of wearable technology facilitates an externally worn mechatronic tremor suppression device as a potential alternative approach for tremor management. However, no device has been developed for the suppression of finger tremor that has been validated on a human. It has been reported in the literature that tremor can be selectively suppressed by mechanical loading. Therefore, the objectives of this thesis were to develop a wearable tremor suppression device that can suppress tremor at the wrist and the fingers, and to evaluate it on individuals with PD in a pre-clinical trial. To address these objectives, several experiments were performed to quantify hand tremor; an enhanced high-order tremor estimator was developed and evaluated for tremor estimation; and a wearable tremor suppression glove (WTSG) was developed to suppress tremor in the index finger metacarpophalangeal (MCP) joint, the thumb MCP joint, and the wrist. A total of 18 individuals with PD were recruited for characterizing tremor. The frequencies and magnitudes of the linear acceleration, angular velocity, and angular displacement of tremor in the index finger MCP joint, the thumb MCP joint, and the wrist were quantified. The results showed that parkinsonian tremor consists of multiple harmonics, and that the second and third harmonics cannot be ignored. With the knowledge of the tremor characteristics, an enhanced high-order tremor estimator was developed to acquire better tremor estimation accuracy than its lower-order counterpart. In addition, the evaluation of the WTSG was conducted on both a physical tremor simulator and on one individual with PD. The results of the simulation study proved the feasibility of using the WTSG to suppress tremor; and the results of the evaluation on a human subject showed that the WTSG can suppress tremor motion while allowing the user to perform voluntary motions. The WTSG developed as a result of this work has demonstrated the feasibility of managing hand tremor with a mechatronic device, and its validation on a human subject has provided useful insights from the user\u27s perspectives, which facilitate the transition of the WTSG from the lab to the clinic, and eventually to commercial use. Lastly, an evaluation studying the impact of suppressed tremor on unrestricted joints was conducted on 14 individuals with PD. The results showed a significant increase in tremor magnitude in the unrestricted distal joints when the motions of the proximal joints were restricted. The average increase of the tremor magnitude of the index finger MCP joint, the thumb MCP joint, the wrist and the elbow are 54%, 96%, 124%, and 98% for resting tremor, and 50%, 102%, 49%, and 107% for postural tremor, respectively. Such a result provided additional clinical justification for the significance of the development of a wearable mechatronic device for hand tremor management. Although the focus of this thesis is on hand tremor management, the development and evaluation of a full upper-limb tremor suppression device is required as a future step, in order to advance the use of wearable mechatronic devices as one of the valid tremor treatment approaches

    Evaluating EEG–EMG Fusion-Based Classification as a Method for Improving Control of Wearable Robotic Devices for Upper-Limb Rehabilitation

    Get PDF
    Musculoskeletal disorders are the biggest cause of disability worldwide, and wearable mechatronic rehabilitation devices have been proposed for treatment. However, before widespread adoption, improvements in user control and system adaptability are required. User intention should be detected intuitively, and user-induced changes in system dynamics should be unobtrusively identified and corrected. Developments often focus on model-dependent nonlinear control theory, which is challenging to implement for wearable devices. One alternative is to incorporate bioelectrical signal-based machine learning into the system, allowing for simpler controller designs to be augmented by supplemental brain (electroencephalography/EEG) and muscle (electromyography/EMG) information. To extract user intention better, sensor fusion techniques have been proposed to combine EEG and EMG; however, further development is required to enhance the capabilities of EEG–EMG fusion beyond basic motion classification. To this end, the goals of this thesis were to investigate expanded methods of EEG–EMG fusion and to develop a novel control system based on the incorporation of EEG–EMG fusion classifiers. A dataset of EEG and EMG signals were collected during dynamic elbow flexion–extension motions and used to develop EEG–EMG fusion models to classify task weight, as well as motion intention. A variety of fusion methods were investigated, such as a Weighted Average decision-level fusion (83.01 ± 6.04% accuracy) and Convolutional Neural Network-based input-level fusion (81.57 ± 7.11% accuracy), demonstrating that EEG–EMG fusion can classify more indirect tasks. A novel control system, referred to as a Task Weight Selective Controller (TWSC), was implemented using a Gain Scheduling-based approach, dictated by external load estimations from an EEG–EMG fusion classifier. To improve system stability, classifier prediction debouncing was also proposed to reduce misclassifications through filtering. Performance of the TWSC was evaluated using a developed upper-limb brace simulator. Due to simulator limitations, no significant difference in error was observed between the TWSC and PID control. However, results did demonstrate the feasibility of prediction debouncing, showing it provided smoother device motion. Continued development of the TWSC, and EEG–EMG fusion techniques will ultimately result in wearable devices that are able to adapt to changing loads more effectively, serving to improve the user experience during operation

    Design and Development of a Lightweight Ankle Exoskeleton for Human Walking Augmentation

    Get PDF
    RESUMÉ La plupart des exosquelettes motorisés de la cheville ont une masse distale considérable, ce qui limite leur capacité à réduire l’énergie dépensée par l’utilisateur durant la marche. L’objectif de notre travail est de développer un exosquelette de chevilles avec le minimum de masse distale ajoutée comparé aux exosquelettes motorisés de chevilles existants. Aussi, l’exosquelette doit fournir au moins 50 Nm de support au couple de flexion plantaire. L’exosquelette développé dans le cadre de ce mémoire utilise deux câbles Bowden pour transmettre la force mécanique de l’unité d’actionnement attachée à la taille aux deux tiges en fibre de Carbonne attachées à la botte de l’utilisateur. Quand les deux tiges sont tirées, ils génèrent un couple qui supporte le mouvement de flexion plantaire à la fin de la phase d’appui du cycle de marche. Une pièce conçue sur mesure et imprimé en plastique par prototypage rapide a été attachée au tibia pour ajuster la direction des câbles. Une étude d’optimisation a été effectuée pour minimiser la masse des tiges limitant ainsi la masse distale de l’exosquelette (attaché au tibia et pied) à seulement 348 g. Le résultat principal obtenu à partir des tests de marche est la réduction de l’activité des muscles soléaire et gastrocnémien du sujet par une moyenne de 37% et 44% respectivement lors de la marche avec l’exosquelette comparée à la marche normale. Cette réduction s’est produite quand l’exosquelette a fourni une puissance mécanique de 19 ± 2 W avec un actionnement qui a commencé à 38% du cycle de marche. Ce résultat démontre le potentiel de notre exosquelette à réduire le cout métabolique de marche et souligne l’importance de réduire la masse distale d’un exosquelette de marche.----------ABSTRACT Most of powered ankle exoskeletons add considerable distal mass to the user which limits their capacity to reduce the metabolic energy of walking. The objective of the work presented in this master thesis is to develop an ankle exoskeleton with a minimum added distal mass compared to existing autonomous powered ankle exoskeletons, while providing at least 50 Nm of assistive plantar flexion torque. The exoskeleton developed in this master thesis uses Bowden cables to transmit the mechanical force from the actuation unit attached to the waist to the carbon fiber struts fixed on the boot. As the struts are pulled, they create an assistive ankle plantar flexion torque. A 3D-printed brace was attached to the shin to adjust the direction of the cables. A design optimization study was performed to minimize the mass of the struts, thereby limiting the total added distal mass, attached to the shin and foot, to only 348 g. The main result obtained from walking tests was the reduction of the soleus and gastrocnemius muscles activity by an average of 37% and 44% respectively when walking with the exoskeleton compared to normal walking. This reduction occurred when the exoskeleton delivered a mechanical power of 19 ± 2 W with an actuation onset fixed at 38% of the gait cycle. This result shows the potential of the proposed exoskeleton to reduce the metabolic cost of walking and emphasizes the importance of minimizing the distal mass of ankle exoskeletons

    Comparison of DC Motors and Dielectric Elastomer Actuators For Wearable Wrist Exoskeletons

    Get PDF
    Paralysis or loss of strength resulting from stroke requires patients to undergo extensive rehabilitation therapy. It is known that intensive therapy contributes significantly to recovery, but as the number of surviving stroke patients increases, it is difficult for clinics to provide patients with the optimal level of therapy. Robotic devices for wrist rehabilitation have been developed to lessen these problems, but at the moment they are physically large and must be used within a clinical setting. More benefit could be obtained if the devices were portable, so that they could be used by the patients on a daily basis. To reduce the size of these devices, other means of actuation need to be considered, as currently DC motors and the required transmission are too large and heavy. Dielectric elastomer actuators (DEAs) may provide a solution to the actuation problem. The focus of this thesis was to compare DC motors with DEAs for use in a wearable wrist exoskeleton to assist with stroke rehabilitation. A simple setup of the forearm, wrist, and hand was developed for testing DC motors and DEAs. For testing the DC motors, kinematic and dynamic models of the arm were created to develop an inverse dynamics controller used to control the movement of the hand. DEAs were fabricated and tested to determine their capabilities in terms of force and range of motion. Based on the data collected, an electromechanical model was optimized to characterize the behavior of the DEAs. The results show that a single DEA strip is not capable of providing the force or range of motion required for a wearable wrist exoskeleton. Future work can be done to improve DEA design so that they may actuate a wearable wrist exoskeleton or could also be considered for use in other wearable rehabilitation devices

    Touch Technology in Affective Human, Robot, Virtual-Human Interactions: A Survey

    Get PDF
    Given the importance of affective touch in human interactions, technology designers are increasingly attempting to bring this modality to the core of interactive technology. Advances in haptics and touch-sensing technology have been critical to fostering interest in this area. In this survey, we review how affective touch is investigated to enhance and support the human experience with or through technology. We explore this question across three different research areas to highlight their epistemology, main findings, and the challenges that persist. First, we review affective touch technology through the human–computer interaction literature to understand how it has been applied to the mediation of human–human interaction and its roles in other human interactions particularly with oneself, augmented objects/media, and affect-aware devices. We further highlight the datasets and methods that have been investigated for automatic detection and interpretation of affective touch in this area. In addition, we discuss the modalities of affective touch expressions in both humans and technology in these interactions. Second, we separately review how affective touch has been explored in human–robot and real-human–virtual-human interactions where the technical challenges encountered and the types of experience aimed at are different. We conclude with a discussion of the gaps and challenges that emerge from the review to steer research in directions that are critical for advancing affective touch technology and recognition systems. In our discussion, we also raise ethical issues that should be considered for responsible innovation in this growing area
    corecore