1,547 research outputs found

    Modeling of heart rate variability and respiratory muscle activity in organophosphate poisoned patients

    Get PDF
    © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other worksWe propose an extended model of cardiovascular regulation to assess heart rate variability in patients poisoned with organophosphate during their treatment with mechanical ventilation. The model was modified to fit a population of 21 patients poisoned with organophosphorus compounds and undergoing mechanical ventilation. The extended model incorporated the respiratory muscle activity measured by surface electromyography for quantifying the vagal-sympathetic engagement during spontaneous breathing test. The order and structure of the parasympathetic and the sympathetic transfer function with respect to the original model were modified to a second-order system. In this extended model, the parameters related to the vagal-sympathetic response (corner frequency and constant gain) were correlated with respiratory muscle activity. When the diaphragm's contractions were stronger, the sympathetic corner frequency increased while the parasympathetic corner frequency and gain decreased. Thus, the proposed model could be useful to improve the ventilatory support and pharmacological treatment for patients poisoned with organophosphorus compounds considering the vagal-sympathetic response inferred from the respiratory muscle activityPeer ReviewedPostprint (author's final draft

    Unified Quality-Aware Compression and Pulse-Respiration Rates Estimation Framework for Reducing Energy Consumption and False Alarms of Wearable PPG Monitoring Devices

    Get PDF
    Due to the high demands of tiny, compact, lightweight, and low-cost photoplethysmogram (PPG) monitoring devices, these devices are resource-constrained including limited battery power. Consequently, it highly demands frequent charge or battery replacement in the case of continuous PPG sensing and transmission. Further, PPG signals are often severely corrupted under ambulatory and exercise recording conditions, leading to frequent false alarms. In this paper, we propose a unified quality-aware compression and pulse-respiration rates estimation framework for reducing energy consumption and false alarms of wearable and edge PPG monitoring devices by exploring predictive coding techniques for jointly performing signal quality assessment (SQA), data compression and pulse rate (PR) and respiration rate (RR) estimation without the use of different domains of signal processing techniques that can be achieved by using the features extracted from the smoothed prediction error signal. By using the five standard PPG databases, the performance of the proposed unified framework is evaluated in terms of compression ratio (CR), mean absolute error (MAE), false alarm reduction rate (FARR), processing time (PT) and energy saving (ES). The compression, PR, RR estimation, and SQA results are compared with the existing methods and results of uncompressed PPG signals with sampling rates of 125 Hz and 25 Hz. The proposed unified qualityaware framework achieves an average CR of 4%, SQA (Se of 92.00%, FARR of 84.87%), PR (MAE: 0.46 ±1.20) and RR (MAE: 1.75 (0.65-4.45), PT (sec) of 15.34 ±0.01) and ES of 70.28% which outperforms the results of uncompressed PPG signal with a sampling rate of 125 Hz. Arduino Due computing platformbased implementation demonstrates the real-time feasibility of the proposed unified quality-aware PRRR estimation and data compression and transmission framework on the limited computational resources. Thus, it has great potential in improving energy-efficiency and trustworthiness of wearable and edge PPG monitoring devices.publishedVersio

    Ultra Wideband

    Get PDF
    Ultra wideband (UWB) has advanced and merged as a technology, and many more people are aware of the potential for this exciting technology. The current UWB field is changing rapidly with new techniques and ideas where several issues are involved in developing the systems. Among UWB system design, the UWB RF transceiver and UWB antenna are the key components. Recently, a considerable amount of researches has been devoted to the development of the UWB RF transceiver and antenna for its enabling high data transmission rates and low power consumption. Our book attempts to present current and emerging trends in-research and development of UWB systems as well as future expectations

    Aerospace Medicine and Biology: A continuing bibliography with indexes (supplement 134)

    Get PDF
    This special bibliography lists 301 reports, articles, and other documents introduced into the NASA Scientific and Technical Information System in October 1974

    Electronic devices and systems for monitoring of diabetes and cardiovascular diseases

    Get PDF
    Diabetes is a serious chronic disease which causes a high rate of morbidity and mortality all over the world. In 2007, more than 246 million people suffered from diabetes worldwide and unfortunately the incidence of diabetes is increasing at alarming rates. The number of people with diabetes is expected to double within the next 25 years due to a combination of population ageing, unhealthy diets, obesity and sedentary lifestyles. It can lead to blindness, heart disease, stroke, kidney failure, amputations and nerve damage. In women, diabetes can cause problems during pregnancy and make it more likely for the baby to be born with birth defects. Moreover, statistical analysis shows that 75% of diabetic patients die prematurely of cardiovascular disease (CVD). The absolute risk of cardiovascular disease in patients with type 1 (insulin-dependent) diabetes is lower than that in patients with type 2 (non-insulin-dependent) diabetes, in part because of their younger age and the lower prevalence of CVD risk factors, and in part because of the different pathophysiology of the two diseases. Unfortunately, about 9 out of 10 people with diabetes have type 2 diabetes. For these reasons, cardiopathes and diabetic patients need to be frequently monitored and in some cases they could easily perform at home the requested physiological measurements (i.e. glycemia, heart rate, blood pressure, body weight, and so on) sending the measured data to the care staff in the hospital. Several researches have been presented over the last years to address these issues by means of digital communication systems. The largest part of such works uses a PC or complex hardware/software systems for this purpose. Beyond the cost of such systems, it should be noted that they can be quite accessible by relatively young people but the same does not hold for elderly patients more accustomed to traditional equipments for personal entertainment such as TV sets. Wearable devices can permit continuous cardiovascular monitoring both in clinical settings and at home. Benefits may be realized in the diagnosis and treatment of a number of major 15 diseases. In conjunction with appropriate alarm algorithms, they can increase surveillance capabilities for CVD catastrophe for high-risk subjects. Moreover, they could play an important role in the wireless surveillance of people during hazardous operations (military, fire-fighting, etc.) or during sport activities. For patients with chronic cardiovascular disease, such as heart failure, home monitoring employing wearable device and tele-home care systems may detect exacerbations in very early stages or at dangerous levels that necessitate an emergency room visit and an immediate hospital admission. Taking into account mains principles for the design of good wearable devices and friendly tele-home care systems, such as safety, compactness, motion and other disturbance rejection, data storage and transmission, low power consumption, no direct doctor supervision, it is imperative that these systems are easy to use and comfortable to wear for long periods of time. The aim of this work is to develop an easy to use tele-home care system for diabetes and cardiovascular monitoring, well exploitable even by elderly people, which are the main target of a telemedicine system, and wearable devices for long term measuring of some parameters related to sleep apnoea, heart attack, atrial fibrillation and deep vein thrombosis. Since set-top boxes for Digital Video Broadcast Terrestrial (DVB-T) are in simple computers with their Operating System, a Java Virtual Machine, a modem for the uplink connection and a set of standard ports for the interfacing with external devices, elderly, diabetics and cardiopathes could easily send their self-made exam to the care staff placed elsewhere. The wearable devices developed are based on the well known photopletysmographic method which uses a led source/detector pair applied on the skin in order to obtain a biomedical signal related to the volume and percentage of oxygen in blood. Such devices investigate the possibility to obtain more information to those usually obtained by this technique (heart rate and percentage of oxygen saturation) in order to discover new algorithms for the continuous and remote or in ambulatory monitoring and screening of sleep apnoea, heart attack, atrial fibrillation and deep vein thrombosis

    Intelligent Biosignal Processing in Wearable and Implantable Sensors

    Get PDF
    This reprint provides a collection of papers illustrating the state-of-the-art of smart processing of data coming from wearable, implantable or portable sensors. Each paper presents the design, databases used, methodological background, obtained results, and their interpretation for biomedical applications. Revealing examples are brain–machine interfaces for medical rehabilitation, the evaluation of sympathetic nerve activity, a novel automated diagnostic tool based on ECG data to diagnose COVID-19, machine learning-based hypertension risk assessment by means of photoplethysmography and electrocardiography signals, Parkinsonian gait assessment using machine learning tools, thorough analysis of compressive sensing of ECG signals, development of a nanotechnology application for decoding vagus-nerve activity, detection of liver dysfunction using a wearable electronic nose system, prosthetic hand control using surface electromyography, epileptic seizure detection using a CNN, and premature ventricular contraction detection using deep metric learning. Thus, this reprint presents significant clinical applications as well as valuable new research issues, providing current illustrations of this new field of research by addressing the promises, challenges, and hurdles associated with the synergy of biosignal processing and AI through 16 different pertinent studies. Covering a wide range of research and application areas, this book is an excellent resource for researchers, physicians, academics, and PhD or master students working on (bio)signal and image processing, AI, biomaterials, biomechanics, and biotechnology with applications in medicine
    corecore