46 research outputs found

    Composite force sensing foot utilizing volumetric displacement of a hyperelastic polymer

    Get PDF
    Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.Cataloged from student-submitted PDF version of thesis.Includes bibliographical references (p. 65-67).In this thesis, I will describe the fabrication and characterization of a footpad based on an original principle of volumetric displacement sensing. It is intended for use in detecting ground contact forces in a running quadrupedal robot. The footpad is man- ufactured as a monolithic, composite structure composed of multi-graded polymers which are reinforced by glass fiber to increase durability and traction. The volumetric displacement sensing principle utilizes a hyperelastic gel-like pad with embedded magnets that are tracked with Hall-effect sensors. Normal and shear forces can be detected as contact with the ground which causes the gel-like pad to deform into rigid wells. This is all done without the need to expose the sensor. A one-time training process using an artificial neural network was used to relate the normal and shear forces with the volumetric displacement sensor output. The sensor was shown to pre- dict normal forces in the Z-axis up to 80N with a root mean squared error of 6.04% as well as the onset of shear in the X and Y-axis. This demonstrates a proof-of-concept for a more robust footpad sensor suitable for use in all outdoor conditions.by Meng Yee (Michael) Chuah.S.M

    Applying safe flooring in housing environments related to the independent elderly : evaluating suitability flooring technology to absorb impact in the event of a fall

    Get PDF
    Aplicat embargament des de la data de defensa fins el dia 3/6/2022This research has been developed with the intention of investigating a different generation of pavements. Most of the current pavements have the same basic standard characteristics and this ensures that living conditions are comfortable, safe, and pleasant for the majority of citizens. But a small group of pavements is designed with a specific purpose: to reduce injuries related to people's falls to the ground; They are called CF (compliant flooring in English). A detailed study of CF flooring systems is warranted to assess their usability for vulnerable groups such as the elderly. This study is structured in six chapters. The first chapter has dealt mainly with bibliographic studies and statistical data consulted on official and international websites. This section evaluates the importance of the increase in the elderly population, life expectancy, and threats to the safety and health of the elderly, especially, and their secondary effects. The scope of the research has been carried out internationally, in Europe and within Spain, and finally, specifically for Catalonia. The second chapter presents a brief overview of the interior flooring, specifically considering its comfort and safety during use. The importance and direct relationship between the sole of the foot and the gait mechanism with respect to the type of pavement have been verified. Many factors that influence this have been investigated, such as the physics and biomechanics of the body when walking, the kinematics of falls, and the dynamics of impact. In addition, a general description of the behavior of materials for use in pavements has been made to better understand the behavior of CF systems. In addition, the most suitable strategies to cope with falls and reduce injuries are discussed. Examining other products with appreciable energy-absorbing and shock-reducing capabilities has been helpful in the proposed pre-designs, all of which have been made based on numerical analysis and related standards. The third chapter is already dedicated to the study of technology and research on the most suitable CF systems; studies from academic, commercial, and architecture departments, in general, are included. In this section, some standard tests related to the various selected materials are developed and several examples of similar products are studied. The fourth chapter includes field research (on-site) and analysis of case studies. Several notable flooring companies around the world were contacted by mail, specifically examining those products whose manufacturers claimed to be shock absorbers. This part of the investigation was slowed down by the delay in shipments. Once they arrived, a real environment was sought where they could obtain the opinion of the elderly and the personnel assigned to their care. All the practice tests were carried out in a residence for the elderly in Barcelona for about two months, focusing on the study of the current pavements of the center and the current derived problems related to users.This entire process was completed by interviewing users and caregivers with predefined questionnaires. It should be noted that this allowed us to contrast the quantitative characteristics of the study in combination with the elements of qualitative research. Chapter Five deals with the results, discussions, suggestions for installation and improvement of pavement safety in risk areas. Simulations were also carried out on a possible base structure of the pavements with the finite element method (FEM). Chapter six presents guidelines for future developments. The author further investigated the materials and their structure and is presented them as a basis for future technical developments.The author considers that, with more detailed studies, it would be possible to use as CF system other materials, either natural or recycled based on agricultural products, which would increase the diversity of the CF system offer and promote more sustainable architectureEsta investigación se ha desarrollado con la intención de investigar una generación diferente de pavimentos. La mayoría de los actuales pavimentos tienen las mismas características básicas estándar y ello garantiza que las condiciones de vida sean cómodas, seguras y agradables para la mayoría de los ciudadanos. Pero un grupo reducido de pavimentos está diseñado con un propósito específico: reducir las lesiones relacionadas con las caídas al suelo de las personas; son los denominados CF (compliant flooring en inglés). Un estudio detallado de los sistemas de pavimentos CF está justificado para evaluar su posibilidad de uso para grupos vulnerables como los ancianos. Este estudio se estructura en seis capítulos. En el primer capítulo se han abordado principalmente los estudios bibliográficos y datos estadísticos consultados en sitios web oficiales e internacionales. En esta sección se evalúa la importancia del aumento de la población anciana. El ámbito de la investigación se ha realizado a nivel internacional, en Europa y dentro de España, y finalmente, específicamente para Cataluña. El segundo capítulo se presenta una breve panorámica del pavimento interior. Se ha constatado la importancia y relación directa entre la planta del pie y el mecanismo de andar con respecto al tipo de pavimento. Se han investigado muchos factores que influyen en ello. Además, se ha realizado una descripción general del comportamiento de los materiales al uso en pavimentos para comprender mejor el comportamiento de los sistemas de CF. Además, se discuten las estrategias más idóneas para hacer frente a las caídas y reducir las lesiones. Examinar otros productos con apreciables capacidades de amortiguación de energía y reducción de impactos ha sido de gran ayuda en los prediseños propuestos, todos los cuales se han realizado sobre la base de análisis numérico y los estándares relacionados. El tercer capítulo está dedicado ya al estudio de la tecnología y la investigación sobre los sistemas de C más idóneos; se incluyen estudios procedentes de departamentos académicos, comerciales y de arquitectura en general. En esta sección se desarrollan algunas pruebas estándar relacionadas con los diversos materiales seleccionados y se estudian varios ejemplos de productos similares. El cuarto capítulo incluye investigación de campo (in situ) y análisis de estudios de casos. Se contactó por correo con varias empresas notables de pavimentos en todo el mundo, y se examinaron específicamente aquellos productos cuyos fabricantes afirmaban ser amortiguadores. Esta parte de la investigación se vio ralentizada por la demora en los envíos. Una vez llegados se buscó un ámbito real donde poder recabar la opinión de las personas mayores y del personal adscrito a su cuidado. Todas las pruebas prácticas se realizaron en una residencia de ancianos de Barcelona durante unos dos meses, centrándose en el estudio de los actuales pavimentos del centro y los problemas actuales derivados relacionados con los usuarios. Todo este proceso se completó mediante entrevistas a usuarios y cuidadores con cuestionarios predefinidos. El Capítulo Cinco se refiere a los resultados, discusiones, sugerencias para la instalación y mejora de la seguridad del pavimento en áreas de riesgo. También se realizaron simulaciones sobre una posible estructura base de los pavimentos con el método elemento finito (FEM). El capítulo seis presenta directrices para desarrollos futuros. El autor investigó más a fondo sobre los materiales y su estructura, y se presenta como una base para desarrollos técnicos futuros. El autor considera que, con estudios más detallados, sería posible utilizar como CF otros materiales, bien naturales o reciclados a base de productos agrícolas, lo cual aumentaría la diversidad de la oferta de CF y fomentaría la arquitectura más sostenible.Postprint (published version

    Ferroelectrets: from material science to energy harvesting and sensor applications

    Get PDF
    The purpose of this thesis is to develop innovative ferroelectrets that can be used in energy harvesting devices as well as mechanical sensors. In the first stage, the focus lies on the application of ferroelectrets as energy harvesters. The inability to control the environment where the energy harvesters will be applied, requires the use of materials that can be utilized in harsh environment such as high temperature or humidity. Therefore, new ferroelectrets based on polymers with excellent electret properties, such as fluoroethylene propylene (FEP) are developed. Two types of ferroelectrets are considered, one optimized for the longitidunal piezoelectric effect and the other one optimized for the transverse piezoelectric effect in these materials. Hereby, new void structures are achieved through thermally fusing such films so that parallel tunnels (parallel-tunnel ferroelectrets) are formed between them, or by fusing round-section FEP tubes together so that they form a band or membrane. The FEP tube configuration is optimized based on a finite element model showing that implementing a single tube structure (25 mm × 1.5 mm) as the energy harvester exhibits the largest output power. By building the energy harvester and modeling it analytically, it is demonstrated that the generated power is highly dependent on parameters such as wall thickness, load resistance, and seismic mass. Utilizing a seismic mass of 80 g at resonance frequencies around 80 Hz and an input acceleration of 1 g (9.81 m s−2), output powers up to 300 μW are reached for a transducer with 25 μm thick walls. The parallel-tunnel ferroelectrets (40 mm × 10 mm) are characterized and used in an energy harvester device based on the transverse piezoelectric effect. The energy harvesting device is an air-spaced cantilever arrangement produced by additive manufacturing technique (3D-printing). The device is tested by exposing it to sinusoidal vibrations with an acceleration a, generated by a shaker. By placing the ferroelectret at a defined distance from the neutral axis of the cantilever beam and using a proper pre-stress of the ferroelectret, an output power exceeding 1000 μW at the resonance frequency of approximately 35 Hz is reached. This demonstrates a significant improvement of air-spaced vibrational energy harvesting with ferroelectrets and greatly exceeds previous performance data for ferroelectret energy harvester of maximal 230 μW. In the second stage of the dissertation, the focus is shifted to develop ferroelectrets for chosen applications such as force myography, ultrasonic transducer and smart insole. Hereby, new arrangements and manufacturing methods are investigated to build the ferroelectret sensors. Furthermore, and following the recent requirements of eco-friendlier sensors, ferroelectrets based on polylactic acid (PLA) are investigated. PLA is a biodegradable and bioabsorbable material derived from renewable plant sources, such as corn or potato starch, tapioca roots, and sugar canes. This work relays a promising new technique in the fabrication of ferroelectrets. The novel structure is achieved through sandwiching a 3D-printed grid of periodically spaced thermoplastic polyurethane (TPU) spacers and air channels between two 12.5 μm-thick FEP films. Due to the ultra-soft TPU sections, very high quasistatic (22.000 pC N−1) and dynamic (7500 pC N−1) d33-coefficients are achieved. The isothermal stability of the d33-coefficients showed a strong dependence on poling temperature. Furthermore, the thermally stimulated discharge currents revealed well-known instability of positive charge carriers in FEP, thereby offering the possibility of stabilization by high-temperature poling. A similar approach is taken by replacing the environmentally harmful FEP by PLA. Large piezoelectric d33-coefficients of up to 2850 pC N−1 are recorded directly after charging and stabilized at about 1500 pC N−1 after approximately 50 days under ambient environmental conditions. These ferroelectrets when used for force myography to detect the slightest muscle movement when moving a finger, resulted in signal shapes and magnitudes that can be clearly distinguished from each other using simple machine learning algorithms known as Support Vector Machine (SVM) with a classification accuracy of 89.5%. Following the new manufacturing route using 3D-printing, an insole is printed using pure polypropylene filament and consists of eight independent sensors, each with a piezoelectric d33 coefficient of approximately 2000 pC N−1. The active part of the insole is protected using a 3D-printed PLA cover that features eight defined embossments on the bottom part, which focus the force on the sensors and act as overload protection against excessive stress. In addition to determining the gait pattern, an accelerometer is implemented to measure kinematic parameters and validate the sensor output signals. The combination of the high sensitivity of the sensors and the kinematic movement of the foot, opens new perspectives regarding diagnosis possibilities through gait analysis. By 3D-printing a PLA backplate and using it in combination with a bulk PLA film, a new possibility to build ultrasonic transducers is presented. The ultrasonic transducer consists of three main components all made from PLA: the film presenting the vibrating plate, the printed backplate with well-defined groves, and the printed holder. The PLA film and the printed backplate build together the ferroelectret with artificial air voids. The printed holder clamps the film on the backplate and fixes the ferroelectret together. The resulting sound pressure is measured with a calibrated microphone (Type 4138, Bruel & Kjaer) at a distance of 30 cm. The biodegradable ultrasonic transducer exhibits a large bandwidth of approximately 45 kHz and fractional bandwidth of 70%. The resulting sound pressure at the resonance frequency can be increased from 98 dB up to 106 dB for driving voltages from 30 to 70 V. respectively. The obtained theoretical and experimental results are an excellent base for further optimizing ferroelectrets to be accepted in the field of energy harvesting and mechanical sensors, where flexibility and high sensitivity are mandatory for the applications

    Sensores em fibra ótica para o estudo biomecânico do disco intervertebral

    Get PDF
    Doutoramento em Engenharia MecânicaO presente trabalho teve como objetivo principal estudar o comportamento mecânico do disco intervertebral recorrendo a sensores em fibra ótica. Na expetativa de efetuar o melhor enquadramento do tema foi efetuada uma revisão exaustiva das várias configurações de sensores em fibra ótica que têm vindo a ser utilizadas em aplicações biomédicas e biomecânicas, nomeadamente para medição de temperatura, deformação, força e pressão. Nesse âmbito, procurou-se destacar as potencialidades dos sensores em fibra ótica e apresentá-los como uma tecnologia alternativa ou até de substituição das tecnologias associadas a sensores convencionais. Tendo em vista a aplicação de sensores em fibra ótica no estudo do comportamento do disco intervertebral efetuou-se também uma revisão exaustiva da coluna vertebral e, particularmente, do conceito de unidade funcional. A par de uma descrição anatómica e funcional centrada no disco intervertebral, vértebras adjacentes e ligamentos espinais foram ainda destacadas as suas propriedades mecânicas e descritos os procedimentos mais usuais no estudo dessas propriedades. A componente experimental do presente trabalho descreve um conjunto de experiências efetuadas com unidades funcionais cadavéricas utilizando sensores convencionais e sensores em fibra ótica com vista à medição da deformação do disco intervertebral sob cargas compressivas uniaxiais. Inclui ainda a medição in vivo da pressão intradiscal num disco lombar de uma ovelha sob efeito de anestesia. Para esse efeito utilizou-se um sensor comercial em fibra ótica e desenvolveu-se a respetiva unidade de interrogação. Finalmente apresenta-se os resultados da investigação em curso que tem como objetivo propor e desenvolver protótipos de sensores em fibra ótica para aplicações biomédicas e biomecânicas. Nesse sentido, são apresentadas duas soluções de sensores interferométricos para medição da pressão em fluídos corporais.The present work aimed to study the mechanical behavior of the intervertebral disc using fiber optic sensors. To address the theme an exhaustive review of the various configurations of fiber optic sensors that have been used in biomechanical and biomedical applications, in particular for measuring temperature, strain, force and pressure, was conducted. In this context, an effort was made to highlight the advantages of fiber optic sensors and present them as an alternative or even a substitution technology to conventional sensors. In view of the application of fiber optic sensors to study intervertebral disc behavior an exhaustive review of the spine and, particularly, of the spinal motion segment was made. Along with an anatomical and functional description of the intervertebral disc, the adjacent vertebrae and spinal ligaments, their mechanical properties were also highlighted as well as the most common procedures and guidelines followed in the study of these properties. The experimental section of the present work describes a set of tests performed with cadaveric spinal motion segments using conventional and fiber optic sensors to assess strain of the intervertebral disc under uniaxial compressive loads. This section also includes an experience reporting in vivo pressures measured in the lumbar disc of a sheep under general anesthesia. In this case, a commercial fiber optic sensor and a purpose-built interrogation unit were used. Finally, the results of ongoing research aiming to develop fiber optic sensors prototypes for biomedical and biomechanical applications are presented. Thus, the proof of concept of two possible interferometric configurations intended for pressure measurement in body fluids was presented

    Engineering Dynamics and Life Sciences

    Get PDF
    From Preface: This is the fourteenth time when the conference “Dynamical Systems: Theory and Applications” gathers a numerous group of outstanding scientists and engineers, who deal with widely understood problems of theoretical and applied dynamics. Organization of the conference would not have been possible without a great effort of the staff of the Department of Automation, Biomechanics and Mechatronics. The patronage over the conference has been taken by the Committee of Mechanics of the Polish Academy of Sciences and Ministry of Science and Higher Education of Poland. It is a great pleasure that our invitation has been accepted by recording in the history of our conference number of people, including good colleagues and friends as well as a large group of researchers and scientists, who decided to participate in the conference for the first time. With proud and satisfaction we welcomed over 180 persons from 31 countries all over the world. They decided to share the results of their research and many years experiences in a discipline of dynamical systems by submitting many very interesting papers. This year, the DSTA Conference Proceedings were split into three volumes entitled “Dynamical Systems” with respective subtitles: Vibration, Control and Stability of Dynamical Systems; Mathematical and Numerical Aspects of Dynamical System Analysis and Engineering Dynamics and Life Sciences. Additionally, there will be also published two volumes of Springer Proceedings in Mathematics and Statistics entitled “Dynamical Systems in Theoretical Perspective” and “Dynamical Systems in Applications”
    corecore